This Advisory is provided to inform you about activities of the District which may affect your operation. It is hoped that it will assist you in your effort to achieve and maintain compliance with applicable air pollution rules and regulations.
ARCHITECTURAL COATINGS
ADVISORY FOR REGULATION 8, RULE 03: ARCHITECTURAL COATINGS
- On January 1, 2003, lower VOC limits for some Architectural Coatings will go into effect.
| Type of Coating |
Old VOC limit grams/liter |
New VOC limit grams/liter |
| Flat Coatings |
250 |
100 |
| Non flat Coatings, except High Gloss |
250 |
150 |
| Bond Breakers |
600 |
350 |
| Clear Wood Lacquer (inc. lacquer sanding sealer) |
680 |
550 |
| Clear Wood Sanding Sealer |
550 |
350 |
| Fire Resistive Coatings |
450 |
350 |
| Fire Retardant Coatings - Clear |
850 |
650 |
| Fire Retardant Coatings - Opaque |
450 |
350 |
| Floor Coatings |
400 |
250 |
| Multi-Color Coatings |
580 |
250 |
| Primers, Sealers, Undercoaters |
350 |
200 |
| Quick-Dry Enamels |
400 |
250 |
| Quick-Dry Primers, Sealers, Undercoaters |
450 |
200 |
| Rust Preventative Coatings |
420 |
400 |
| Stains |
350 |
250 |
| Swimming Pool |
600 |
340 |
| Swimming Pool Repair and Maintenance |
600 |
340 |
| Waterproofing Sealers |
400 |
250 |
| Below-ground Wood Preservatives |
550 |
350 |
- Sell-Through: The new limits affect coatings manufactured on or after January 1, 2003. Coatings in compliance with the old VOC limits that were manufactured before January 1 may be sold until January 1, 2006. They may be used indefinitely.
- Thinning: You cannot thin or reduce coatings with organic solvent beyond manufacturer's recommendations or to exceed the VOC limit. This does not apply to water or exempt solvents.
- Close containers of any VOC materials (coatings, thinners, clean-up solvents) when not in use.
If you have any further needs, please click on the following links or call the District at the following numbers:
|