BAY AREA AIR QUALITY MANAGEMENT DISTRICT
Best Available Control Technology (BACT) Guideline

Source Category

Source: Liquid Transfer & Handling - Marine Loading Revision: 1
Document #: 107.1
Class: All Date: 10/28/91

Determination

POLLUTANT

BACT
1. Technologically Feasible/ Cost Effective
2. Achieved in Practice
TYPICAL TECHNOLOGY
POC 1.  n/d
2.  Vapor recovery and control system: compressor, condenser, and thermal incinerator w/ a destruction efficiency >98.5%
b
1. n/d
2.  BAAQMD Approved Design and Operation
b
NOx 1. n/a
2. n/a
1.  n/a
2. n/a
SO2 1. n/a
2. n/a
1.  n/a
2. n/a
CO 1. n/a
2. n/a
1.  n/a
2. n/a
PM10 1. n/a
2. n/a
1.  n/a
2. n/a
NPOC 1.  n/d
2.  Vapor recovery system  w/ an overall system efficiency >95%
b
1. n/d
2.  Vapor Balance; or Refrigerated Condenser; or Carbon Adsorber; or BAAQMD Approved Equivalent
b

References

b. BAAQMD