BAY AREA AIR QUALITY
MANAGEMENT DISTRICT |
Source Category
| Source: | Hot MIx Asphalt, Drum Mix Facilities | Revision: | 1 |
| Document #: | 10A.1 | ||
| Class: | All | Date: | 03/06/01 |
Determination
POLLUTANT |
BACT 1. Technologically Feasible/ Cost Effective 2. Achieved in Practice |
TYPICAL TECHNOLOGY |
| POC | 1. Afterburner w/ >0.3
sec. retention time at >1400oFa,T 2. n/s |
1. BAAQMD Approved Design
and Operationa 2. Good Combustion Practicea |
| NOx | 1. n/d 2. 12 ppmv @15% O2 Dry a,b,c |
1. n/d 2. Natural Gas + Low NOx Combustion System a,b,c |
| SO2 | 1. n/d 2. Natural gas a,b,c |
1. n/d 2. Fuel Selection a,b,c |
| CO | 1. n/d 2. 133 ppmv @ 15% O2 Dry a,b,c |
1. n/d 2. Good Combustion Practicea,c |
| PM10 | 1. n/d 2. <0.01 gr/dscf a,T |
1. n/d 2. Baghousea,T |
| NPOC | 1. n/a 2. n/a |
1. n/a 2. n/a |
References
| a. BAAQMD b. BACT is 12 ppmvd NOx @ 15% O2 and 265 ppmvd CO @ 15% O2 regardless of fuel. However, for special situations such as temporary operations and/or remote locations where natural gas is not available, liquefied petroleum gas or fuel oil < 0.05 wt. % sulfur may be permitted to emit at higher levels as specified below: 1). "Temporary operations" using exclusively liquefied petroleum gas shall not remain at any single plant for a period in excess of 12 consecutive months, following the date of initial operation, and may be permitted up to 38 ppmvd NOx @ 15% O2and 265 ppmvd CO @ 15% O2. [Basis: Monterey Bay Unitied APCD A/C #10287] 2). "Temporary operations" using exclusively fuel oil < 0.05 wt. % sulfur shall not remain at any single plant for a period in excess of 3 consecutive months, following the date of initial operation, and may be permitted up to 55 ppmvd NOx @ 15% O2 and 265 ppmvd CO @ 15% O2.[Basis: Reference a. above] 3). For remote locations where natural gas is not available, liquefied petroleum gas may be permitted up to 38 ppmvd NOx @ 15% O2 and 265 ppmvd CO @ 15% O2 and fuel oil < 0.05 wt. % sulfur may be permitted up to 55 ppmvd NOx @ 15% O2 and 265 ppmvd CO @ 15% O2. [Basis: Monterey Bay APCD A/C #10287 and Reference a. above] c. BAAQMD A #17860 T. TBACT |