BAY AREA AIR QUALITY MANAGEMENT DISTRICT
Best Available Control Technology (BACT) Guideline

Source Category

Source: Asphalt Roofing Line Revision: 1
Document #: 11.1
Class: All Date: 11/08/91

Determination

POLLUTANT

BACT
1. Technologically Feasible/ Cost Effective
2. Achieved in Practice
TYPICAL TECHNOLOGY
POC 1. Enclosure and vent to afterburner w/ >0.3 sec at >1400oF
2. n/d
1.  BAAQMD Approved Design and Operationb
2. n/d
NOx 1.  n/d
2. Natural gas firing
1.  n/d
2. Fuel Selection
SO2 1. n/d
2. Natural gas firing
1. n/d
2. Fuel Selection
CO 1. n/a
2.  n/a
1. n/a
2.  n/a
PM10 1. Natural gas firing and afterburner w/ >0.3 sec at >1400oF
2. Natural gas firing and high velocity filter & mist eliminator
1. BAAQMD Approved Design and Operationb
2. BAAQMD Approved Design and Operationb
NPOC 1. n/a
2.  n/a
1.  n/a
2.  n/a

References

b. BAAQMD