BAY AREA AIR QUALITY MANAGEMENT DISTRICT
Best Available Control Technology (BACT) Guideline

Source Category

Source: Sewage Treatment Plant -
High Purity Oxygen Activated Sludge
Revision: 2
Document #: 150.1.3
Class: All Date: 06/02/95

Determination

POLLUTANT

BACT
1. Technologically Feasible/ Cost Effective
2. Achieved in Practice
TYPICAL TECHNOLOGY
POC 1.  n/s



2.  n/s
1.  Vapor phase controls (odor control equipment, activated carbon or alumina systems, or combustion abatement device)a,T
2.  Industrial source control
a,T
NOx 1. n/a
2.  n/a
1.  n/a
2. n/a
SO2 1. n/s


2. n/s
1.  Ferrous Chloride Injection and Caustic Scrubber for Hydrogen Sulfide Removala
2.  Ferrous Chloride Injection for Hydrogen Sulfide Removal
a
CO 1. n/a
2.  n/a
1.  n/a
2. n/a
PM10 1. n/a
2.  n/a
1.  n/a
2. n/a
NPOC 1. n/a
2.  n/a
1.  n/a
2. n/a

References

a. BAAQMD
b. Draft Tri-TAC VOC Control Technology Guidance Document
T. TBACT