BAY AREA AIR QUALITY MANAGEMENT DISTRICT
Best Available Control Technology (BACT) Guideline

Source Category

Source: Spray Booth - Coating of Misc. Metal Parts and Products Revision: 1
Document #: 161.5.2
Class: >50 lb/day Emissions (Uncontrolled) Date: 12/13/91

Determination

POLLUTANT

BACT
1. Technologically Feasible/ Cost Effective
2. Achieved in Practice
TYPICAL TECHNOLOGY
POC 1.  Coating w/ VOC content less than and transfer efficiency greater than that required by
Reg. 8, Rule 19, and emissions controlled to overall capture/ destruction efficiency >90%
a
2. Complying w/ VOC content and transfer efficiency complying w/ Reg. 8, Rule 19, and emissions controlled to overallcapture/ destruction efficiency  >90%
a
1. Collection System Vented to Carbon Adsorber or Afterburnera



2. Collection System Vented to Carbon Adsorber or Afterburnera
NOx 1. n/a
2.  n/a
1.  n/a
2. n/a
SO2 1. n/a
2.  n/a
1.  n/a
2. n/a
CO 1. n/a
2.  n/a
1.  n/a
2. n/a
PM10 1. n/d
2.  n/s
1.  n/d
2. Dry Filters or Waterwash, Properly Maintained
a
NPOC 1.  Coating w/ solvent content less than and transfer efficiency greater than that required by
Reg. 8, Rule 19, and emissions controlled to overall capture/ destruction efficiency >90%
a
2. Coating w/ solvent content and transfer efficiency complying w/ Reg. 8, Rule 19, and emissions controlled to overallcapture/ destruction efficiency  >90%
a
1. Collection System Vented to Carbon Adsorbera



2. Collection System Vented to Carbon Adsorbera

References

a. BAAQMD