BAY AREA AIR QUALITY
MANAGEMENT DISTRICT |
Source Category
| Source: | Spray Booth - Coating of flatwood Paneling & Wood Flat Stock | Revision: | 1 |
| Document #: | 161.7.1 | ||
| Class: | <50 lb/day Emissions (Uncontrolled) | Date: | 09/06/91 |
Determination
POLLUTANT |
BACT 1. Technologically Feasible/ Cost Effective 2. Achieved in Practice |
TYPICAL TECHNOLOGY |
| POC | 1. Coating w/ VOC
content and transfer efficiency complying w/ Reg. 8, Rule 23, and emissions controlled to
overall capture/ destruction efficiency >90%a,c 2. Compliance w/ Reg. 8, Rule 23a |
1. Collection System
Vented to Carbon Adsorber or Afterburnera,c 2. Low VOC Coatingsa |
| NOx | 1. n/a 2. n/a |
1. n/a 2. n/a |
| SO2 | 1. n/a 2. n/a |
1. n/a 2. n/a |
| CO | 1. n/a 2. n/a |
1. n/a 2. n/a |
| PM10 | 1. n/d 2. n/s |
1. n/d 2. Dry Filters or Waterwash, Properly Maintaineda |
| NPOC | 1. Coating w/ VOC
content and transfer efficiency complying w/ Reg. 8, Rule 23, and emissions controlled to
overall capture/ destruction efficiency >90%a,c 2. Compliance w/ Reg. 8, Rule 23a |
1. Collection System
Vented to Carbon Adsorbera,c 2. Low Solvent Coatingsa |
References
| a. BAAQMD c. Generally considered to be cost-effective if uncontrolled emissions >50 lb/day |