BAY AREA AIR QUALITY
MANAGEMENT DISTRICT |
Source Category
| Source: | Storage tank - External Floating Roof, Organic Liquids | Revision: | 2 |
| Document #: | 167.1.1 | ||
| Class: | All | Date: | 03/03/95 |
Determination
POLLUTANT |
BACT 1. Technologically Feasible/ Cost Effective 2. Achieved in Practice |
TYPICAL TECHNOLOGY |
| POC | 1. Vapor recovery system w/
an overall system efficiency >98%a,T 2. BAAQMD Approved roof w/ liquid mounted primary seal and zero gap secondary seal, all meeting design criteria of Reg. 8, Rule 5. Also, no ungasketed roof penetrations, no slotted pipe guide pole unless equipped with float and wiper seals, and no adjustable roof legs unless fitted w/ vapor seal boots or equivalenta,T |
1. Thermal
Incinerator; or Carbon Adsorber; or Refrigerated Condenser; or BAAQMD approved equivalenta,T 2. BAAQMD Approved Roof and Seal Designa,T |
| NOx | 1. n/a 2. n/a |
1. n/a 2. n/a |
| SO2 | 1. n/a 2. n/a |
1. n/a 2. n/a |
| CO | 1. n/a 2. n/a |
1. n/a 2. n/a |
| PM10 | 1. n/a 2. n/a |
1. n/a 2. n/a |
| NPOC | 1. Vapor recovery
system w/ an overall system efficiency >98%a,T 2. Same as for POC above |
1. Carbon Adsorber;
or Refrigerated Condenser; or BAAQMD approved equivalenta,T 2. BAAQMD Approved Roof and Seal Designa,T |
References
| a. BAAQMD T. TBACT |