BAY AREA AIR QUALITY
MANAGEMENT DISTRICT |
Source Category
| Source: | Storage Tank - Fixed Roof, Organic Liquids | Revision: | 2 |
| Document #: | 167.3.1 | ||
| Class: | >20,000 Gallons | Date: | 03/03/95 |
Determination
POLLUTANT |
BACT 1. Technologically Feasible/ Cost Effective 2. Achieved in Practice |
TYPICAL TECHNOLOGY |
| POC | 1. n/d 2. Vapor recovery system w/ an overall system efficiency >98%a,T |
1. n/d 2. Thermal Incinerator; or Carbon Adsorber; or Refrigerated Condenser; or BAAQMD approved equivalenta,T |
| NOx | 1. n/a 2. n/a |
1. n/a 2. n/a |
| SO2 | 1. n/a 2. n/a |
1. n/a 2. n/a |
| CO | 1. n/a 2. n/a |
1. n/a 2. n/a |
| PM10 | 1. n/a 2. n/a |
1. n/a 2. n/a |
| NPOC | 1. n/d 2. Vapor recovery system w/ an overall system efficiency >98%a,T |
1. n/d 2. Carbon Adsorber; or Refrigerated Condenser; or BAAQMD approved equivalenta,T |
References
| a. BAAQMD T. TBACT |