BAY AREA AIR QUALITY
MANAGEMENT DISTRICT |
Source Category
| Source: | Boiler - Municipal Refuse Fired | Revision: | 1 |
| Document #: | 17.8.1 | ||
| Class: | All | Date: | 08/05/91 |
Determination
POLLUTANT |
BACT 1. Technologically Feasible/ Cost Effective 2. Achieved in Practice |
TYPICAL TECHNOLOGY |
| POC | 1. n/d 2. 50 ppm @ 12% CO2a |
1. n/d 2. Boiler Design (Overfire Air Jets) + Automatic Combustion Air Control |
| NOx | 1. n/s 2. 200 ppm @ 12% CO2a |
1. SCR + Staged Combustion
and Automatic Combustion Air Control + Natural Gas as Auxiliary Fuel 2. Flue Gas Recirculation + Combustion Modificationa |
| SO2 | 1. n/d 2. 30 ppm @ 12% CO2a |
1. n/d 2. Dry Scrubber with Baghouse + Natural Gas as Auxiliary Fuela |
| CO | 1. n/d 2. 100 ppm @ 12% CO2a |
1. Catalytic Oxidation 2. Boiler Design (Overfire Air Jets) + Automatic Combustion Air Control |
| PM10 | 1. <0.002 gr/dscf
@ 12% CO2 2. <0.005 gr/dscf @ 12% CO2 |
1. Baghouse and Natural Gas
as auxiliary Fuel 2. Baghouse and Natural Gas as auxiliary Fuel |
| NPOC | 1. n/a 2. n/a |
1. n/a 2. n/a |
References
| a. CARB/CAPCOA Clearinghouse |