BAY AREA AIR QUALITY
MANAGEMENT DISTRICT |
Source Category
| Source: | Air Stripper - Ground Water Treatment | Revision: | 3 |
| Document #: | 2.1.1 | ||
| Class: | All | Date: | 06/16/95 |
etermination
POLLUTANT |
BACT 1. Technologically Feasible/ Cost Effective 2. Achieved in Practice |
TYPICAL TECHNOLOGY |
| POC | 1. <10 ppmv at
outlet of control device; or >98.5% capture/destruction efficiencya,T 2. <10 ppmv at outlet of control device; or >98.5% capture/destruction efficiency if inlet VOC >2000 ppmv; or >97% capture/destruction efficiency if inlet VOC >200 to <2000 ppmv; or >90% capture/destruction efficiency if inlet VOC <200 ppmva,T |
1. Two or More Activated
Carbon Canister in Series or Thermal Oxidizera,T 2. Two or More Activated Carbon Canisters in Series or Thermal Oxidizer or Catalytic Oxidizera,T |
| NOx | 1. n/a 2. n/a |
1. n/a 2. n/a |
| SO2 | 1. n/a 2. n/a |
1. n/a 2. n/a |
| CO | 1. n/a 2. n/a |
1. n/a 2. n/a |
| PM10 | 1. n/a 2. n/a |
1. n/a 2. n/a |
| NPOC | 1. <10 ppmv at
outlet of control devicea,T 2. <10 ppmv at outlet of control device; or >95% capture/recovery efficiencya,T |
1. Two or More Activated
Carbon Canisters in Series a,T 2. Two or More Activated Carbon Canisters in Series a,T |
References
| a. BAAQMD T. TBACT |