BAY AREA AIR QUALITY MANAGEMENT DISTRICT
Best Available Control Technology (BACT) Guideline

Source Category

Source: Catalyst Regeneration - Fluidized Catalytic Cracking Unit Revision: 1
Document #: 38.1
Class: All Date: 08/05/91

Determination

POLLUTANT

BACT
1. Technologically Feasible/ Cost Effective
2. Achieved in Practice
TYPICAL TECHNOLOGY
POC 1. n/d
2.  Waste heat boiler w/ >0.5 sec. retention time at >1600oF a
1. n/d
2.  BAAQMD Approved Design and Operation
a
NOx 1. n/d
2.  n/d
b
1. n/d
2.  n/d
b
SO2 1. n/d
2.  n/s
b
1. n/d
2.  FCCU Feed Desulfurization (Feed Hydrotreater) or DE-SOx Catalyst (Additive to FCCU Catalyst)
b
CO 1.  n/d
2.  Waste heat boiler w/ >0.5 sec. retention time at >1600oF
a
1. n/a
2.  BAAQMD Approved Design and Operation
a
PM10 1.  n/d
2.  n/s
1.  n/d
2.  Multicyclone and Electrostatic Precipitator
a
NPOC 1. n/a
2.  n/a
1. n/a
2. n/a

References

a. BAAQMD
b. See also Boiler, CO - Refinery