BAY AREA AIR QUALITY
MANAGEMENT DISTRICT |
Source Category
| Source: | Degreaser - Solvent Spray Booth | Revision: | 1 |
| Document #: | 54.3 | ||
| Class: | All | Date: | 10/07/91 |
Determination
POLLUTANT |
BACT 1. Technologically Feasible/ Cost Effective 2. Achieved in Practice |
TYPICAL TECHNOLOGY |
| POC | 1. n/d 2. Solvent spray cleaning in a hood, booth, or room vented to a control device, w/ emissions controlled to overall capture/destruction efficiency >90%a |
1. n/d 2. Collection System Vented to Carbon Adsorber System w/ Two Carbon Canisters in Seriesa |
| NOx | 1. n/a 2. n/a |
1. n/a 2. n/a |
| SO2 | 1. n/a 2. n/a |
1. n/a 2. n/a |
| CO | 1. n/a 2. n/a |
1. n/a 2. n/a |
| PM10 | 1. n/a 2. n/a |
1. n/a 2. n/a |
| NPOC | 1. n/d 2. Same as for POC above |
1. n/d 2. Same as for POC above |
References
| a. BAAQMD A #1810 |