BAY AREA AIR QUALITY
MANAGEMENT DISTRICT |
Source Category
| Source: | Drycleaner - Valclene & Other Synthetic Solvents | Revision: | 3 |
| Document #: | 58.3.1 | ||
| Class: | All | Date: | 01/27/99 |
Determination
POLLUTANT |
BACT 1. Technologically Feasible/ Cost Effective 2. Achieved in Practice |
TYPICAL TECHNOLOGY |
| POC | 1. n/a 2. n/a |
1. n/a 2. n/a |
| NOx | 1. n/a 2. n/a |
1. n/a 2. n/a |
| SO2 | 1. n/a 2. n/a |
1. n/a 2. n/a |
| CO | 1. n/a 2. n/a |
1. n/a 2. n/a |
| PM10 | 1. n/a 2. n/a |
1. n/a 2. n/a |
| NPOC | 1. n/d 2. Secondary Control Machine (ventless dry-to-dry system with internal refrigerated condenser, internal carbon adsorption unit, and drying sensor/controller) achieving solvent concentration in drum <300 ppmva,T,E |
1. n/d 2. BAAQMD Approved Design and Operationa,T,E |
References
| a. BAAQMD Regulation 11, Rule 16 T. TBACT. E. Exception: Closed loop machines (ventless dry-to-dry system with internal refrigerated condenser achieving outlet vapor temperature <45oF, and drying sensor/controller) at existing non-residential facilities are allowed to be "relocated" to a non-residential facility that is owned and operated by the same owner/operator as the previous existing facility (Regulation 11, Rule 16, Sections 104 and 250). |