BAY AREA AIR QUALITY
MANAGEMENT DISTRICT |
Source Category
| Source: | Flexographic Printing Line | Revision: | 2 |
| Document #: | 83.1 | ||
| Class: | All | Date: | 06/20/95 |
Determination
POLLUTANT |
BACT 1. Technologically Feasible/ Cost Effective 2. Achieved in Practice |
TYPICAL TECHNOLOGY |
| POC | 1. Water reducible inks w/ <1
lb VOC/gal of coating and no VOC clean-up solvents. If cost-effective, capture and
vent VOC to afterburner or carbon adsorption sytem w/ > 98.5%
destruction/recovery device efficiency, or VOC outlet <10 ppmva,b,T 2. Water reducible inks w/ either: <1.5 lb VOC/gal coating or <10% by volume VOC; and no VOC clean-up solvnetsa,T |
1. Low VOC Coatings
and no VOC clean-up solvents; or BAAQMD approved Collection System and Abatement Devicea,b,T 2. Low VOC Coatings and no VOC clean-up solventsa,T |
| NOx | 1. n/a 2. n/a |
1. n/a 2. n/a |
| SO2 | 1. n/a 2. n/a |
1. n/a 2. n/a |
| CO | 1. n/a 2. n/a |
1. n/a 2. n/a |
| PM10 | 1. n/a 2. n/a |
1. n/a 2. n/a |
| NPOC | 1. Same as for POC
abovea,b,T 2. Same as for POC abovea,b,T |
1. Low or no NPOC
Coatings and Solvents: or BAAQMD Approved Abatement Systema,b,T 2. Low NPOC Coatings and Solventsa,T |
References