BAY AREA AIR QUALITY
MANAGEMENT DISTRICT |
Source Category
| Source: | Heater - Refinery Process, Natural or Induced Draft | Revision: | 3 |
| Document #: | 94.1.1 | ||
| Class: | 5 MMBtu/hr to <50 MMBtu/hr Heat Input | Date: | 08/12/94 |
Determination
POLLUTANT |
BACT 1. Technologically Feasible/ Cost Effective 2. Achieved in Practice |
TYPICAL TECHNOLOGY |
| POC | 1. n/d 2. n/s |
1. n/d 2. Good Combustion Practicea |
| NOx | 1. 10 ppmv @ 3% O2
Drya,b,c,e 2. 25 ppmv @ 3% O2 Drya,b,e |
1. Selective Catalytic
Reduction (SCR) + Low NOx Burnersa,b,c 2. Low NOx Burners; or Low NOx Burners + Selective Non-Catalytic Reduction (SNCR)a,d |
| SO2 | 1. Natural Gas or
Treated Refinery Gas Fuel w/ <50 ppmv Hydrogen Sulfide and <100 ppmv Total Reduced Sulfura 2. Natural Gas or Treated` Refinery Gas Fuel w/ <100 ppmv Total Reduced Sulfura |
1. Fuel Selectiona 2. Fuel Selectiona |
| CO | 1. n/d 2. 50 ppmv @ 3% O2 Drya,f |
1. n/d 2. Good Combustion Practicea |
| PM10 | 1. n/d 2. Natural Gas or Treated Refinery Gas Fuela,b |
1. n/d 2. Fuel Selectiona,b |
| NPOC | 1. n/a 2. n/a |
1. n/a 2. n/a |
References
| a. BAAQMD b. BAAQMD A #30783 c. BAAQMD A #3318 d. BAAQMD A #8407 e. NOx determination by BAAQMD Source Test Method ST-13A or B (average of three 30-minute sampling runs); or Continuous Emission Monitor (3-hour average); or BAAQMD approved equivalent. f. CO determination by BAAQMD Source Test Method ST-6 (average of three 30 minute sampling runs); or Continuous Emission Monitor (3-hour average); or BAAQMD approved equivalent. |