BAY AREA AIR QUALITY MANAGEMENT DISTRICT
Best Available Control Technology (BACT) Guideline

Source Category

Source: Incinerator - Non-Infectious Waste Revision: 1
Document #: 95.3.1
Class: < 300 lb/hr Date: 10/25/91

Determination

POLLUTANT

BACT
1. Technologically Feasible/ Cost Effective
2. Achieved in Practice
TYPICAL TECHNOLOGY
POC 1. n/d
2.  Multiple chamber, starved air design (>0.5 sec. retention time at >1600
oF)a
1. n/d
2. BAAQMD Approved Design and Operation
b
NOx 1.  n/d
2. n/s
1.  n/d
2.  Natural Gas as Auxiliary Fuel
a
SO2 1.  n/s

2.  n/s
1. Natural Gas as Auxiliary Fuel with Dry Scrubber and Baghousea
2.  Natural Gas as Auxiliary Fuel with Wet Scrubber
a
CO 1. n/d
2.  Multiple chamber, starved air design (>0.5 sec. retention time at >1600
oF)a
1. n/d
2. BAAQMD Approved Design and Operation
b
PM10 1. n/s



2. n/s
1. Natural Gas as Auxiliary Fuel with Baghouse, Gas Quencher, and Enclosed Automatic Feed and Flyash Removal Systema
2.  Natural Gas as Auxiliary Fuel with Enclosed Automatic Feed and Flyash Removal System
a
NPOC 1. n/a
2. n/a
1.  n/a
2. n/a

References

a. SCAQMD Guideline
b. BAAQMD