Search

  • Refinery Emissions Inventory Guidelines
    Refinery Emissions Inventory Guidelines

    Jul 3, 2019 ... Petroleum Refinery Emissions Inventory Guidelines July 2019 Prepared by: Principal Author: Nicholas C. Maiden, P.E., Principal Air Quality Engineer Contributing ...

    Read More
    (897 Kb PDF, 137 pgs)

    Jul 3, 2019 ... Petroleum Refinery Emissions Inventory Guidelines July 2019 Prepared by: Principal Author: Nicholas C. Maiden, P.E., Principal Air Quality Engineer Contributing ...

  • 2008 Staff Report
    2008 Staff Report

    Jun 30, 2008 ... Bay Area Air Quality Management District 939 Ellis Street San Francisco, CA 94109 Staff Report Proposed Amendments to BAAQMD Regulation 9, Rule 7: NITROGEN OXIDES AND CARBON ...

    Read More
    (174 Kb PDF, 33 pgs)

    Jun 30, 2008 ... Bay Area Air Quality Management District 939 Ellis Street San Francisco, CA 94109 Staff Report Proposed Amendments to BAAQMD Regulation 9, Rule 7: NITROGEN OXIDES AND CARBON ...

  • Regulation 9 Rule 7 Draft Rule
    Regulation 9 Rule 7 Draft Rule

    Mar 25, 2008 ... DRAFT 3-18-2008 REGULATION 9 INORGANIC GASEOUS POLLUTANTS RULE 7 NITROGEN OXIDES AND CARBON MONOXIDE FROM INDUSTRIAL, INSTITUTIONAL, AND COMMERCIAL BOILERS, STEAM GENERATORS, AND PROCESS ...

    Read More
    (59 Kb PDF, 12 pgs)

    Mar 25, 2008 ... DRAFT 3-18-2008 REGULATION 9 INORGANIC GASEOUS POLLUTANTS RULE 7 NITROGEN OXIDES AND CARBON MONOXIDE FROM INDUSTRIAL, INSTITUTIONAL, AND COMMERCIAL BOILERS, STEAM GENERATORS, AND PROCESS ...

  • Proposed Amendments, Regulation 9, Rule 7
    Proposed Amendments, Regulation 9, Rule 7

    Apr 4, 2011 ... DRAFT 4-4-2011 REGULATION 9 INORGANIC GASEOUS POLLUTANTS RULE 7 NITROGEN OXIDES AND CARBON MONOXIDE FROM INDUSTRIAL, INSTITUTIONAL, AND COMMERCIAL BOILERS, STEAM GENERATORS, AND PROCESS HEATERS ...

    Read More
    (96 Kb PDF, 15 pgs)

    Apr 4, 2011 ... DRAFT 4-4-2011 REGULATION 9 INORGANIC GASEOUS POLLUTANTS RULE 7 NITROGEN OXIDES AND CARBON MONOXIDE FROM INDUSTRIAL, INSTITUTIONAL, AND COMMERCIAL BOILERS, STEAM GENERATORS, AND PROCESS HEATERS ...

  • 2020_Draft Refinery Emissions Inventory Guidelines_Edits_ July 2020_redline since February 2016 pdf
    2020_Draft Refinery Emissions Inventory Guidelines_Edits_ July 2020_redline since February 2016 pdf

    Jul 9, 2020 ... Petroleum Refinery Emissions Inventory Guidelines Deleted: ne July 2020 Deleted: February Deleted: 19 Deleted: 6 Prepared by: Principal Author: Nicholas C.

    Read More
    (2 Mb PDF, 158 pgs)

    Jul 9, 2020 ... Petroleum Refinery Emissions Inventory Guidelines Deleted: ne July 2020 Deleted: February Deleted: 19 Deleted: 6 Prepared by: Principal Author: Nicholas C.

  • Draft Reg 6 Particulate Matter and Visible Emissions Rule 3 Wood Burning Devices
    Draft Reg 6 Particulate Matter and Visible Emissions Rule 3 Wood Burning Devices

    Aug 17, 2015 ... REGULATION 6 PARTICULATE MATTER AND VISIBLE EMISSIONS RULE 3 WOOD-BURNING DEVICES INDEX 6-3-100 GENERAL 6-3-101 Description 6-3-110 Limited Exemption, Natural Gas Service Unavailability Sole ...

    Read More
    (245 Kb PDF, 9 pgs)

    Aug 17, 2015 ... REGULATION 6 PARTICULATE MATTER AND VISIBLE EMISSIONS RULE 3 WOOD-BURNING DEVICES INDEX 6-3-100 GENERAL 6-3-101 Description 6-3-110 Limited Exemption, Natural Gas Service Unavailability Sole ...

  • Regulation 9, Rule 10: Staff Report
    Regulation 9, Rule 10: Staff Report

    Nov 15, 2010 ... Bay Area Air Quality Management District 939 Ellis Street San Francisco, CA 94109 Staff Report Proposed Amendments to BAAQMD Regulation 9, Rule 10: NITROGEN ...

    Read More
    (165 Kb PDF, 34 pgs)

    Nov 15, 2010 ... Bay Area Air Quality Management District 939 Ellis Street San Francisco, CA 94109 Staff Report Proposed Amendments to BAAQMD Regulation 9, Rule 10: NITROGEN ...

  • Draft Rule
    Draft Rule

    Oct 20, 2015 ... Correction to Non-Functional, Permanently Installed Heater Exemption (Section 111) An administrative error was discovered in the proposed effective date of the Non- functional, Permanently ...

    Read More
    (250 Kb PDF, 9 pgs)

    Oct 20, 2015 ... Correction to Non-Functional, Permanently Installed Heater Exemption (Section 111) An administrative error was discovered in the proposed effective date of the Non- functional, Permanently ...

  • Staff Report Reg 6 Rule 3
    Staff Report Reg 6 Rule 3

    Aug 17, 2015 ... Regulation 6: Particulate Matter and Visible Emissions, Rule 3: Wood Burning Devices Proposed Amendments August 17, 2015 Prepared by: Tracy Lee, Air Quality Specialist ...

    Read More
    (718 Kb PDF, 30 pgs)

    Aug 17, 2015 ... Regulation 6: Particulate Matter and Visible Emissions, Rule 3: Wood Burning Devices Proposed Amendments August 17, 2015 Prepared by: Tracy Lee, Air Quality Specialist ...

  • Statement of Basis
    Statement of Basis

    Nov 5, 2015 ... Bay Area Air Quality Management District 939 Ellis Street San Francisco, CA 94109 (415) 771-6000 Proposed "Revision 5" Permit Evaluation and Statement of Basis for a Minor Revision of ...

    Read More
    (6 Mb PDF, 438 pgs)

    Nov 5, 2015 ... Bay Area Air Quality Management District 939 Ellis Street San Francisco, CA 94109 (415) 771-6000 Proposed "Revision 5" Permit Evaluation and Statement of Basis for a Minor Revision of ...

  • Staff Report
    Staff Report

    Sep 17, 2015 ... Regulation 6: Particulate Matter and Visible Emissions, Rule 3: Wood Burning Devices Proposed Amendments September 18, 2015 Prepared by: Tracy Lee, Air Quality Specialist ...

    Read More
    (850 Kb PDF, 32 pgs)

    Sep 17, 2015 ... Regulation 6: Particulate Matter and Visible Emissions, Rule 3: Wood Burning Devices Proposed Amendments September 18, 2015 Prepared by: Tracy Lee, Air Quality Specialist ...

  • 10/18/2019 Proposed Permit
    10/18/2019 Proposed Permit

    Oct 18, 2019 ... Bay Area Air Quality Management District 375 Beale Street, Suite 600 San Francisco, CA 94105 (415) 771-6000 Final MAJOR FACILITY REVIEW PERMIT Issued To: Chevron Products Company ...

    Read More
    (12 Mb PDF, 970 pgs)

    Oct 18, 2019 ... Bay Area Air Quality Management District 375 Beale Street, Suite 600 San Francisco, CA 94105 (415) 771-6000 Final MAJOR FACILITY REVIEW PERMIT Issued To: Chevron Products Company ...

  • Statement of Basis
    Statement of Basis

    Jan 11, 2016 ... Bay Area Air Quality Management District 939 Ellis Street San Francisco, CA 94109 (415) 771-6000 Final "Revision 5" Permit Evaluation and Statement of Basis for a Minor Revision of ...

    Read More
    (7 Mb PDF, 458 pgs)

    Jan 11, 2016 ... Bay Area Air Quality Management District 939 Ellis Street San Francisco, CA 94109 (415) 771-6000 Final "Revision 5" Permit Evaluation and Statement of Basis for a Minor Revision of ...

  • Regulation 9 Rule 7 Draft MOP
    Regulation 9 Rule 7 Draft MOP

    Mar 25, 2008 ... Manual of Procedures, Volume 1, Chapter 5 DRAFT 5. BOILER, STEAM GENERATOR AND PROCESS HEATER TUNING PROCEDURE 5.1 Inspection Procedure for Boilers, Steam Generators and Process Heaters ...

    Read More
    (65 Kb PDF, 6 pgs)

    Mar 25, 2008 ... Manual of Procedures, Volume 1, Chapter 5 DRAFT 5. BOILER, STEAM GENERATOR AND PROCESS HEATER TUNING PROCEDURE 5.1 Inspection Procedure for Boilers, Steam Generators and Process Heaters ...

  • Installation Costs for Zero-NOx Space and Water Heating Appliances
    Installation Costs for Zero-NOx Space and Water Heating Appliances

    Oct 21, 2024 ... Installation Costs for Zero-NOx Space and Water Heating Appliances Version 2.0 - Rate Updates Bay Area Air Quality Management District prepared for Energy + Environmental Economics (E3), ...

    Read More
    (2 Mb PDF, 89 pgs)

    Oct 21, 2024 ... Installation Costs for Zero-NOx Space and Water Heating Appliances Version 2.0 - Rate Updates Bay Area Air Quality Management District prepared for Energy + Environmental Economics (E3), ...

  • Engineering Evaluation
    Engineering Evaluation

    Dec 31, 2007 ... Bay Area Air Quality Management District 939 Ellis Street San Francisco, CA 94109 (415) 771-6000 Permit Evaluation and Statement of Basis for MAJOR FACILITY REVIEW PERMIT Revision ...

    Read More
    (1 Mb PDF, 267 pgs)

    Dec 31, 2007 ... Bay Area Air Quality Management District 939 Ellis Street San Francisco, CA 94109 (415) 771-6000 Permit Evaluation and Statement of Basis for MAJOR FACILITY REVIEW PERMIT Revision ...

  • Statment of Basis
    Statment of Basis

    Apr 29, 2013 ... Bay Area Air Quality Management District 939 Ellis Street San Francisco, CA 94109 (415) 771-6000 Permit Evaluation and Statement of Basis for Revision 3 MAJOR FACILITY REVIEW ...

    Read More
    (1 Mb PDF, 91 pgs)

    Apr 29, 2013 ... Bay Area Air Quality Management District 939 Ellis Street San Francisco, CA 94109 (415) 771-6000 Permit Evaluation and Statement of Basis for Revision 3 MAJOR FACILITY REVIEW ...

  • Statement of Basis
    Statement of Basis

    Mar 1, 2013 ... Bay Area Air Quality Management District 939 Ellis Street San Francisco, CA 94109 (415) 771-6000 Permit Evaluation and Statement of Basis for Revision 3 MAJOR FACILITY REVIEW ...

    Read More
    (1 Mb PDF, 91 pgs)

    Mar 1, 2013 ... Bay Area Air Quality Management District 939 Ellis Street San Francisco, CA 94109 (415) 771-6000 Permit Evaluation and Statement of Basis for Revision 3 MAJOR FACILITY REVIEW ...

  • Engineering Evaluation Proposed Permit
    Engineering Evaluation Proposed Permit

    Sep 9, 2010 ... Bay Area Air Quality Management District 939 Ellis Street San Francisco, CA 94109 (415) 771-6000 Permit Evaluation and Statement of Basis for RENEWAL of MAJOR FACILITY REVIEW ...

    Read More
    (2 Mb PDF, 136 pgs)

    Sep 9, 2010 ... Bay Area Air Quality Management District 939 Ellis Street San Francisco, CA 94109 (415) 771-6000 Permit Evaluation and Statement of Basis for RENEWAL of MAJOR FACILITY REVIEW ...

  • Board Agenda
    Board Agenda

    May 7, 2026 ... Board of Directors MEETING May 13, 2026 MEETING LOCATION(S) FOR IN-PERSON ATTENDANCE BY BOARD MEMBERS AND MEMBERS OF THE PUBLIC Bay Area Metro Center Office of Contra Costa County 1st Floor ...

    Read More
    (2 Mb PDF, 91 pgs)

    May 7, 2026 ... Board of Directors MEETING May 13, 2026 MEETING LOCATION(S) FOR IN-PERSON ATTENDANCE BY BOARD MEMBERS AND MEMBERS OF THE PUBLIC Bay Area Metro Center Office of Contra Costa County 1st Floor ...

Spare the Air Status