Advisory
|
Valero Refinery in Benicia notified the Air District of ongoing flaring due to a planned shutdown of refinery equipment. Air District inspectors will be closely monitoring. Report air quality complaints: 800-334-ODOR or online.
|
|
135 results for 'sampling sampling'
Search: 'sampling sampling'
135 Search:
The Air District is convening a community workgroup to inform development and implementation of our new Particle Fallout Sampling Program for refinery communities. We are looking for people who live or work near the Chevron, Marathon, MRC, Phillips 66, and Valero refineries, or who represent organizations and environmental groups that serve these communities.
Read MoreThe Air District is convening a community workgroup to inform development and implementation of our new Particle Fallout Sampling Program for refinery communities. We are looking for people who live or work near the Chevron, Marathon, MRC, Phillips 66, and Valero refineries, or who represent organizations and environmental groups that serve these communities.
Oct 1, 1996 ... Source Test Procedure ST-23 WATER VAPOR (Adopted January 20, 1982) 1. APPLICABILITY 1.1 This method is used to quantify the water vapor content of stack gases. It is applicable in all cases in which ...
Read MoreOct 1, 1996 ... Source Test Procedure ST-23 WATER VAPOR (Adopted January 20, 1982) 1. APPLICABILITY 1.1 This method is used to quantify the water vapor content of stack gases. It is applicable in all cases in which ...
Jan 18, 2018 ... Sampling Study Protocol Specifications for Third-Party Verifiers Fugitive Emissions from Petroleum Refinery Equipment in Heavy Liquid Service Joint Study between the Bay Area Air ...
Read MoreJan 18, 2018 ... Sampling Study Protocol Specifications for Third-Party Verifiers Fugitive Emissions from Petroleum Refinery Equipment in Heavy Liquid Service Joint Study between the Bay Area Air ...
oct. 1, 1996 ... Source Test Procedure ST-22 TRIMETHYLAMINE (Adopted January 20, 1982) REF: Regulation 7-303 1. APPLICABILITY 1.1 This method is used to quantify emissions of Trimethylamine (TMA). It determines ...
Read Moreoct. 1, 1996 ... Source Test Procedure ST-22 TRIMETHYLAMINE (Adopted January 20, 1982) REF: Regulation 7-303 1. APPLICABILITY 1.1 This method is used to quantify emissions of Trimethylamine (TMA). It determines ...
Sep 27, 1996 ... Source Test Method ST-8 DIMETHYLSULFIDE (Adopted January 20, 1982) REF: Regulation 7-303 1. APPLICABILITY 1.1 This method is used to determine emissions of dimethylsulfide (DMS). It is applicable ...
Read MoreSep 27, 1996 ... Source Test Method ST-8 DIMETHYLSULFIDE (Adopted January 20, 1982) REF: Regulation 7-303 1. APPLICABILITY 1.1 This method is used to determine emissions of dimethylsulfide (DMS). It is applicable ...
Sep 26, 1996 ... Source Test Procedure ST-2 BERYLLIUM (Adopted January 20, 1982) REF: Regulation 11-3-301 1. APPLICABILITY 1.1 This procedure is used to quantify emissions of Beryllium. It determines compliance with ...
Read MoreSep 26, 1996 ... Source Test Procedure ST-2 BERYLLIUM (Adopted January 20, 1982) REF: Regulation 11-3-301 1. APPLICABILITY 1.1 This procedure is used to quantify emissions of Beryllium. It determines compliance with ...
Sep 27, 1996 ... Source Test Procedure ST-10 MERCURY Adopted (January 20, 1982) REF: Regulation 11-5-301 1. APPLICABILITY 1.1 This method is used to quantify emissions of gaseous and particulate mercury. It ...
Read MoreSep 27, 1996 ... Source Test Procedure ST-10 MERCURY Adopted (January 20, 1982) REF: Regulation 11-5-301 1. APPLICABILITY 1.1 This method is used to quantify emissions of gaseous and particulate mercury. It ...
Sep 27, 1996 ... Source Test Method ST-11 MERCAPTANS Adopted (January 20, 1982) REF: Regulation 7-303 1. APPLICABILITY 1.1 This method is used to determine emissions of mercaptans. It is applicable to the ...
Read MoreSep 27, 1996 ... Source Test Method ST-11 MERCAPTANS Adopted (January 20, 1982) REF: Regulation 7-303 1. APPLICABILITY 1.1 This method is used to determine emissions of mercaptans. It is applicable to the ...
sep. 27, 1996 ... Source Test Procedure ST-9 LEAD Adopted (January 20, 1982) REF: Regulation, 11-1-301 1. APPLICABILITY 1.1 This procedure is used to quantify emissions of Lead. It determines compliance with ...
Read Moresep. 27, 1996 ... Source Test Procedure ST-9 LEAD Adopted (January 20, 1982) REF: Regulation, 11-1-301 1. APPLICABILITY 1.1 This procedure is used to quantify emissions of Lead. It determines compliance with ...
Oct 1, 1996 ... Source Test Procedure ST-25 FLUORIDE, INTEGRATED SAMPLE (Adopted January 20, 1982) REF: Regulation 10-1-301 1. APPLICABILITY 1.1 This method is used to quantify emissions of fluoride. It ...
Read MoreOct 1, 1996 ... Source Test Procedure ST-25 FLUORIDE, INTEGRATED SAMPLE (Adopted January 20, 1982) REF: Regulation 10-1-301 1. APPLICABILITY 1.1 This method is used to quantify emissions of fluoride. It ...
Sep 27, 1996 ... Source Test Procedure ST-14 OXYGEN, CONTINUOUS SAMPLING Adopted January 20, 1982 REF: Regulations 9-3-301, 9-3-302 1. APPLICABILITY 1.1 This method is used to quantify emissions of oxygen. It ...
Read MoreSep 27, 1996 ... Source Test Procedure ST-14 OXYGEN, CONTINUOUS SAMPLING Adopted January 20, 1982 REF: Regulations 9-3-301, 9-3-302 1. APPLICABILITY 1.1 This method is used to quantify emissions of oxygen. It ...
Sep 27, 1996 ... Source Test Procedure ST-5 CARBON DIOXIDE, CONTINUOUS SAMPLING REF: Regulation 6-310.1 1. APPLICABILITY 1.1 This method is used to quantify emissions of carbon dioxide. It determines compliance ...
Read MoreSep 27, 1996 ... Source Test Procedure ST-5 CARBON DIOXIDE, CONTINUOUS SAMPLING REF: Regulation 6-310.1 1. APPLICABILITY 1.1 This method is used to quantify emissions of carbon dioxide. It determines compliance ...
may. 10, 2023 ... May 10, 2023 Request for Qualifications# 2023-030 Air Sampling Network Maintenance and Operations SECTION I – SUMMARY ...
Read Moremay. 10, 2023 ... May 10, 2023 Request for Qualifications# 2023-030 Air Sampling Network Maintenance and Operations SECTION I – SUMMARY ...
feb. 2, 2021 ... February 3, 2021 Request for Qualifications# 2020-001 Air Sampling Network Maintenance and Operations SECTION I – SUMMARY ...
Read Morefeb. 2, 2021 ... February 3, 2021 Request for Qualifications# 2020-001 Air Sampling Network Maintenance and Operations SECTION I – SUMMARY ...
Mar 16, 2016 ... MOP Vol. IX Procedure - 1 Volatile Organic Compounds Water Sampling PROCEDURE - 1 ORGANIC COMPOUNDS WATER SAMPLING REF: Regulation 11-10 1. APPLICABILITY 1.1 This procedure is used to ...
Read MoreMar 16, 2016 ... MOP Vol. IX Procedure - 1 Volatile Organic Compounds Water Sampling PROCEDURE - 1 ORGANIC COMPOUNDS WATER SAMPLING REF: Regulation 11-10 1. APPLICABILITY 1.1 This procedure is used to ...
sep. 27, 1996 ... Source Test Procedure ST-19B TOTAL SULFUR OXIDES, INTEGRATED SAMPLE REF: Regulations 9-1-302, 9-1-304 through 310, 10-1-301 1. APPLICABILITY 1.1 This method is used to quantify emissions of total ...
Read Moresep. 27, 1996 ... Source Test Procedure ST-19B TOTAL SULFUR OXIDES, INTEGRATED SAMPLE REF: Regulations 9-1-302, 9-1-304 through 310, 10-1-301 1. APPLICABILITY 1.1 This method is used to quantify emissions of total ...
sep. 27, 1996 ... Source Test Procedure ST-13A OXIDES OF NITROGEN, CONTINUOUS SAMPLING REF: Regulations 9-3-301, 9-3-302, 10-1-301 1. APPLICABILITY 1.1 This method is used to quantify emissions of oxides of nitrogen.
Read Moresep. 27, 1996 ... Source Test Procedure ST-13A OXIDES OF NITROGEN, CONTINUOUS SAMPLING REF: Regulations 9-3-301, 9-3-302, 10-1-301 1. APPLICABILITY 1.1 This method is used to quantify emissions of oxides of nitrogen.
Aug 11, 2023 ... South Bay Odor Attribution Study Final Report 230407112709_08bfbc6e Bay Area Air Quality Management District Document Title B a y A r e a A i r Q u a l i t y M a n a g ...
Read MoreAug 11, 2023 ... South Bay Odor Attribution Study Final Report 230407112709_08bfbc6e Bay Area Air Quality Management District Document Title B a y A r e a A i r Q u a l i t y M a n a g ...
ago. 27, 2013 ... Guidelines for Construction of Particulate Sampling and Testing Facilities Introduction Selection of a proper sampling site is vital to assure representative measurement of pollutant ...
Read Moreago. 27, 2013 ... Guidelines for Construction of Particulate Sampling and Testing Facilities Introduction Selection of a proper sampling site is vital to assure representative measurement of pollutant ...
Última actualización: 08/11/2016