Búsqueda

  • 20744 Permit Evaluation
    20744 Permit Evaluation

    ene. 15, 2010 ... DRAFT Engineering Evaluation Robinson’s Family Trust Plant No. 19735; Application No. 20744 Background Robinson’s Family Trust has applied for an authority to construct for soil remediation ...

    Read More
    (38 Kb PDF, 5 pgs)

    ene. 15, 2010 ... DRAFT Engineering Evaluation Robinson’s Family Trust Plant No. 19735; Application No. 20744 Background Robinson’s Family Trust has applied for an authority to construct for soil remediation ...

  • 22917 Permit Evaluation
    22917 Permit Evaluation

    mar. 3, 2011 ... DRAFT Engineering Evaluation ConocoPhillips 76 Service Station No. 3816 Plant No. 20563; Application No. 22917 Background Stantec Consulting Corporation, on behalf of ConocoPhillips has ...

    Read More
    (99 Kb PDF, 4 pgs)

    mar. 3, 2011 ... DRAFT Engineering Evaluation ConocoPhillips 76 Service Station No. 3816 Plant No. 20563; Application No. 22917 Background Stantec Consulting Corporation, on behalf of ConocoPhillips has ...

  • 22812 Permit Evaluation
    22812 Permit Evaluation

    ene. 21, 2011 ... DRAFT Engineering Evaluation Integral Engineering Services, Inc. Plant No. 20512 Application No. 22812 Background Integral Engineering Services, Inc. has applied for an authority to ...

    Read More
    (105 Kb PDF, 4 pgs)

    ene. 21, 2011 ... DRAFT Engineering Evaluation Integral Engineering Services, Inc. Plant No. 20512 Application No. 22812 Background Integral Engineering Services, Inc. has applied for an authority to ...

  • 27828 Permit Evaluation
    27828 Permit Evaluation

    Sep 28, 2016 ... Engineering Evaluation West Environmental for Former Mee Rae Malette/Payless Cleaners 4212-4220 Piedmont Avenue, Oakland, CA 94611 Plant # 23472; Application Number 27828 1. Background: ...

    Read More
    (418 Kb PDF, 5 pgs)

    Sep 28, 2016 ... Engineering Evaluation West Environmental for Former Mee Rae Malette/Payless Cleaners 4212-4220 Piedmont Avenue, Oakland, CA 94611 Plant # 23472; Application Number 27828 1. Background: ...

  • Presentations
    Presentations

    mar. 29, 2016 ... AGENDA: 4 Proposed Fiscal Year End 2017 Budget Budget and Finance Committee March 23, 2016 Jeff McKay Deputy Air Pollution Control ...

    Read More
    (2 Mb PDF, 43 pgs)

    mar. 29, 2016 ... AGENDA: 4 Proposed Fiscal Year End 2017 Budget Budget and Finance Committee March 23, 2016 Jeff McKay Deputy Air Pollution Control ...

  • Regulation 9 Rule 7 Draft MOP
    Regulation 9 Rule 7 Draft MOP

    Mar 25, 2008 ... Manual of Procedures, Volume 1, Chapter 5 DRAFT 5. BOILER, STEAM GENERATOR AND PROCESS HEATER TUNING PROCEDURE 5.1 Inspection Procedure for Boilers, Steam Generators and Process Heaters ...

    Read More
    (65 Kb PDF, 6 pgs)

    Mar 25, 2008 ... Manual of Procedures, Volume 1, Chapter 5 DRAFT 5. BOILER, STEAM GENERATOR AND PROCESS HEATER TUNING PROCEDURE 5.1 Inspection Procedure for Boilers, Steam Generators and Process Heaters ...

  • 20819 Permit Evaluation
    20819 Permit Evaluation

    oct. 14, 2009 ... DRAFT Engineering Evaluation Pangea Environmental Services, Inc. (US Gas Station) Plant No. 19773; Application No. 20819 Background Pangea Environmental Services, Inc. has applied for an ...

    Read More
    (37 Kb PDF, 5 pgs)

    oct. 14, 2009 ... DRAFT Engineering Evaluation Pangea Environmental Services, Inc. (US Gas Station) Plant No. 19773; Application No. 20819 Background Pangea Environmental Services, Inc. has applied for an ...

  • 30963 Permit Evaluation
    30963 Permit Evaluation

    may. 25, 2021 ... DRAFT Engineering Evaluation: Soil Vapor Extraction Former Norge Cleaners 2114 MacArthur Blvd, Oakland, CA 94602 Application No. 30963; Plant No. 24890 Background Former Norge Cleaners has ...

    Read More
    (224 Kb PDF, 6 pgs)

    may. 25, 2021 ... DRAFT Engineering Evaluation: Soil Vapor Extraction Former Norge Cleaners 2114 MacArthur Blvd, Oakland, CA 94602 Application No. 30963; Plant No. 24890 Background Former Norge Cleaners has ...

  • Boiler, Steam Generator, and Process Heater Tuning Procedure
    Boiler, Steam Generator, and Process Heater Tuning Procedure

    ago. 7, 2008 ... 5. BOILER, STEAM GENERATOR AND PROCESS HEATER TUNING PROCEDURE 5.1 Inspection Procedure for Boilers, Steam Generators and Process Heaters 5.1.1 Using a thermometer and probe with a ...

    Read More
    (64 Kb PDF, 6 pgs)

    ago. 7, 2008 ... 5. BOILER, STEAM GENERATOR AND PROCESS HEATER TUNING PROCEDURE 5.1 Inspection Procedure for Boilers, Steam Generators and Process Heaters 5.1.1 Using a thermometer and probe with a ...

  • 23276 Permit Evaluation
    23276 Permit Evaluation

    jul. 5, 2011 ... DRAFT Engineering Evaluation Presidio Trust Plant No. 20733; Application No. 23276 Background On behalf of Presidio Trust, AMEC Geomatric has applied for an authority to construct for soil ...

    Read More
    (102 Kb PDF, 4 pgs)

    jul. 5, 2011 ... DRAFT Engineering Evaluation Presidio Trust Plant No. 20733; Application No. 23276 Background On behalf of Presidio Trust, AMEC Geomatric has applied for an authority to construct for soil ...

  • 29526 Permit Evaluation
    29526 Permit Evaluation

    mar. 20, 2019 ... DRAFT ENGINEERING EVALUATION Haley & Aldrich Plant: 24247 Application: 29526 BACKGROUND Haley & Aldrich has applied to obtain an Authority to Construct for the following equipment: ...

    Read More
    (343 Kb PDF, 5 pgs)

    mar. 20, 2019 ... DRAFT ENGINEERING EVALUATION Haley & Aldrich Plant: 24247 Application: 29526 BACKGROUND Haley & Aldrich has applied to obtain an Authority to Construct for the following equipment: ...

  • 29807 Permit Evaluation
    29807 Permit Evaluation

    jul. 3, 2019 ... ENGINEERING EVALUATION POSADA DE COLORES – THE UNITY COUNCIL 2221 FRUITVALE AVENUE OAKLAND, CA 94601 PLANT NO. 24365; APPLICATION NO. 29807 BACKGROUND West Environmental Services & ...

    Read More
    (208 Kb PDF, 5 pgs)

    jul. 3, 2019 ... ENGINEERING EVALUATION POSADA DE COLORES – THE UNITY COUNCIL 2221 FRUITVALE AVENUE OAKLAND, CA 94601 PLANT NO. 24365; APPLICATION NO. 29807 BACKGROUND West Environmental Services & ...

  • 30324 Permit Evaluation
    30324 Permit Evaluation

    jun. 15, 2020 ... Engineering Evaluation: Soil Vapor Extraction BSREP II Station (c/o PES Environmental) th 301 12 Street, Oakland, CA Application No. 30324; Plant No. 24621 Background th On behalf of BSREP ...

    Read More
    (324 Kb PDF, 6 pgs)

    jun. 15, 2020 ... Engineering Evaluation: Soil Vapor Extraction BSREP II Station (c/o PES Environmental) th 301 12 Street, Oakland, CA Application No. 30324; Plant No. 24621 Background th On behalf of BSREP ...

  • 30391 Permit Evaluation
    30391 Permit Evaluation

    jun. 23, 2020 ... Draft Engineering Evaluation: Soil Vapor Extraction DS Westgate West L.P. 5309 Prospect Road, San Jose, CA Application No. 30391; Plant No. 24650 Background On behalf of DS Westgate West ...

    Read More
    (305 Kb PDF, 6 pgs)

    jun. 23, 2020 ... Draft Engineering Evaluation: Soil Vapor Extraction DS Westgate West L.P. 5309 Prospect Road, San Jose, CA Application No. 30391; Plant No. 24650 Background On behalf of DS Westgate West ...

  • Engineering Evaluation
    Engineering Evaluation

    may. 23, 2006 ... Synthetic Minor Operating Permit Application Evaluation Report Isola USA Corp. Application #14105 - Site (Plant) #3024 Background: Isola USA Corp. owns and operates a copper laminate ...

    Read More
    (70 Kb PDF, 16 pgs)

    may. 23, 2006 ... Synthetic Minor Operating Permit Application Evaluation Report Isola USA Corp. Application #14105 - Site (Plant) #3024 Background: Isola USA Corp. owns and operates a copper laminate ...

  • 694801 Permit Evaluation
    694801 Permit Evaluation

    sep. 22, 2025 ... Engineering Evaluation RRM, Inc. 1319 Howard Avenue, Burlingame, CA 94010 Plant No. 21698 Application No. 694801 Background RRM, Inc. has requested a Change of Conditions to an existing ...

    Read More
    (358 Kb PDF, 17 pgs)

    sep. 22, 2025 ... Engineering Evaluation RRM, Inc. 1319 Howard Avenue, Burlingame, CA 94010 Plant No. 21698 Application No. 694801 Background RRM, Inc. has requested a Change of Conditions to an existing ...

  • 28433 Permit Evaluation
    28433 Permit Evaluation

    may. 2, 2017 ... Draft Engineering Evaluation Report Edgewater Holding Corporation, Plant #23786 901 Edgewater Blvd, Foster City, CA Application #28433 Background Edgewater Holding Corporation (“Applicant”) ...

    Read More
    (249 Kb PDF, 6 pgs)

    may. 2, 2017 ... Draft Engineering Evaluation Report Edgewater Holding Corporation, Plant #23786 901 Edgewater Blvd, Foster City, CA Application #28433 Background Edgewater Holding Corporation (“Applicant”) ...

  • 19214 Permit Evaluation
    19214 Permit Evaluation

    feb. 17, 2009 ... DRAFT Engineering Evaluation SOMA Environmental Engineering Inc., Plant No. 19396 Application No. 19214 Background SOMA Environmental Engineering, Inc. has applied for a modification to ...

    Read More
    (39 Kb PDF, 5 pgs)

    feb. 17, 2009 ... DRAFT Engineering Evaluation SOMA Environmental Engineering Inc., Plant No. 19396 Application No. 19214 Background SOMA Environmental Engineering, Inc. has applied for a modification to ...

  • 30832 Permit Evaluation
    30832 Permit Evaluation

    feb. 16, 2022 ... Engineering Evaluation Nova at the Vale - Building C-1 915 De Guigne Dr, Sunnyvale, CA 94085 Plant No. 24830 (Site No. E4830) Application No. 30832 Project Description: Sub-Slab ...

    Read More
    (148 Kb PDF, 6 pgs)

    feb. 16, 2022 ... Engineering Evaluation Nova at the Vale - Building C-1 915 De Guigne Dr, Sunnyvale, CA 94085 Plant No. 24830 (Site No. E4830) Application No. 30832 Project Description: Sub-Slab ...

  • 26416 Permit Evaluation
    26416 Permit Evaluation

    dic. 16, 2014 ... DRAFT ENGINEERING EVALUATION REPORT EXXON MOBIL OIL CORPORATION PLANT NUMBER 22530 APPLICATION NUMBER 26416 1201 Tennessee Street Vallejo, CA 94590 Background On behalf of Exxon ...

    Read More
    (32 Kb PDF, 6 pgs)

    dic. 16, 2014 ... DRAFT ENGINEERING EVALUATION REPORT EXXON MOBIL OIL CORPORATION PLANT NUMBER 22530 APPLICATION NUMBER 26416 1201 Tennessee Street Vallejo, CA 94590 Background On behalf of Exxon ...

Spare the Air Status

Última actualización: 08/11/2016