Búsqueda

  • 161 4 2
    161 4 2

    Apr 7, 2014 ... BAY AREA AIR QUALITY MANAGEMENT DISTRICT Best Available Control Technology (BACT) Guideline Source Category Revision: 3 Spray Booth (Automatic Zones) - Source: Document Coating of Motor ...

    Read More
    (97 Kb PDF, 2 pgs)

    Apr 7, 2014 ... BAY AREA AIR QUALITY MANAGEMENT DISTRICT Best Available Control Technology (BACT) Guideline Source Category Revision: 3 Spray Booth (Automatic Zones) - Source: Document Coating of Motor ...

  • 129 4 1
    129 4 1

    abr. 16, 2014 ... BAY AREA AIR QUALITY MANAGEMENT DISTRICT Best Available Control Technology (BACT) Guideline Source Category Revision: 1 Source: Polyester Resin Operations - Pultrusion Document #: 129.4.1 ...

    Read More
    (88 Kb PDF, 1 pg)

    abr. 16, 2014 ... BAY AREA AIR QUALITY MANAGEMENT DISTRICT Best Available Control Technology (BACT) Guideline Source Category Revision: 1 Source: Polyester Resin Operations - Pultrusion Document #: 129.4.1 ...

  • 96 1 4
    96 1 4

    Apr 13, 2009 ... BAY AREA AIR QUALITY MANAGEMENT DISTRICT Best Available Control Technology (BACT) Guideline Source Category IC Engine – Compression Revision: 6 Source: Ignition, Stationary Prime; Document #: ...

    Read More
    (120 Kb PDF, 2 pgs)

    Apr 13, 2009 ... BAY AREA AIR QUALITY MANAGEMENT DISTRICT Best Available Control Technology (BACT) Guideline Source Category IC Engine – Compression Revision: 6 Source: Ignition, Stationary Prime; Document #: ...

  • 161 4 1
    161 4 1

    abr. 7, 2014 ... BAY AREA AIR QUALITY MANAGEMENT DISTRICT Best Available Control Technology (BACT) Guideline Source Category Revision: 3 Spray Booth (Manual Zones) - Source: Document Coating of motor Vehicles, ...

    Read More
    (95 Kb PDF, 1 pg)

    abr. 7, 2014 ... BAY AREA AIR QUALITY MANAGEMENT DISTRICT Best Available Control Technology (BACT) Guideline Source Category Revision: 3 Spray Booth (Manual Zones) - Source: Document Coating of motor Vehicles, ...

  • 96 2 4
    96 2 4

    Jun 3, 2013 ... BAY AREA AIR QUALITY MANAGEMENT DISTRICT Best Available Control Technology (BACT) Guideline Source Category Revision: 1 Source: IC Engine – Biogas Fired Document #: 96.2.4 5/30/2013 Class: > ...

    Read More
    (74 Kb PDF, 2 pgs)

    Jun 3, 2013 ... BAY AREA AIR QUALITY MANAGEMENT DISTRICT Best Available Control Technology (BACT) Guideline Source Category Revision: 1 Source: IC Engine – Biogas Fired Document #: 96.2.4 5/30/2013 Class: > ...

  • 96 3 4
    96 3 4

    Mar 19, 2014 ... Source Category Revision: 1 IC Engine – Spark Ignition, Natural Gas Fired Source: Document Emergency Engine 96.3.4 #: Class: >= 50 HP Date: 5/7/03 Determination POLLUTANT BACT ...

    Read More
    (136 Kb PDF, 1 pg)

    Mar 19, 2014 ... Source Category Revision: 1 IC Engine – Spark Ignition, Natural Gas Fired Source: Document Emergency Engine 96.3.4 #: Class: >= 50 HP Date: 5/7/03 Determination POLLUTANT BACT ...

  • 17 4 1
    17 4 1

    Mar 11, 2014 ... BAY AREA AIR QUALITY MANAGEMENT DISTRICT Best Available Control Technology (BACT) Guideline Source Category Revision: 2 Source: Boiler, CO - Refinery Document #: 17.4.1 Class: All Date: ...

    Read More
    (95 Kb PDF, 1 pg)

    Mar 11, 2014 ... BAY AREA AIR QUALITY MANAGEMENT DISTRICT Best Available Control Technology (BACT) Guideline Source Category Revision: 2 Source: Boiler, CO - Refinery Document #: 17.4.1 Class: All Date: ...

  • 95 4 1
    95 4 1

    abr. 15, 2014 ... BAY AREA AIR QUALITY MANAGEMENT DISTRICT Best Available Control Technology (BACT) Guideline Source Category Revision: 1 Source: Incinerator - Non-Infectious Waste Document #: 95.4.1 Class: > ...

    Read More
    (95 Kb PDF, 1 pg)

    abr. 15, 2014 ... BAY AREA AIR QUALITY MANAGEMENT DISTRICT Best Available Control Technology (BACT) Guideline Source Category Revision: 1 Source: Incinerator - Non-Infectious Waste Document #: 95.4.1 Class: > ...

  • 96 4 1
    96 4 1

    Mar 19, 2014 ... BAY AREA AIR QUALITY MANAGEMENT DISTRICT Best Available Control Technology (BACT) Guideline Source Category Revision: 1 Source: IC Engine - Spark Ignition, Alt. Fuels Document #: 96.4.1 Class: ...

    Read More
    (95 Kb PDF, 1 pg)

    Mar 19, 2014 ... BAY AREA AIR QUALITY MANAGEMENT DISTRICT Best Available Control Technology (BACT) Guideline Source Category Revision: 1 Source: IC Engine - Spark Ignition, Alt. Fuels Document #: 96.4.1 Class: ...

  • 150 1 4
    150 1 4

    Apr 15, 2014 ... BAY AREA AIR QUALITY MANAGEMENT DISTRICT Best Available Control Technology (BACT) Guideline Source Category Revision: 2 Sewage Treatment Plant - Source: Secondary Clarifiers and Tertiary ...

    Read More
    (94 Kb PDF, 1 pg)

    Apr 15, 2014 ... BAY AREA AIR QUALITY MANAGEMENT DISTRICT Best Available Control Technology (BACT) Guideline Source Category Revision: 2 Sewage Treatment Plant - Source: Secondary Clarifiers and Tertiary ...

  • 167 4 1
    167 4 1

    mar. 20, 2014 ... BAY AREA AIR QUALITY MANAGEMENT DISTRICT Best Available Control Technology (BACT) Guideline Source Category Revision: 2 Source: Storage Tank - Internal Floating Roof, Organic Liquids Document #: ...

    Read More
    (95 Kb PDF, 1 pg)

    mar. 20, 2014 ... BAY AREA AIR QUALITY MANAGEMENT DISTRICT Best Available Control Technology (BACT) Guideline Source Category Revision: 2 Source: Storage Tank - Internal Floating Roof, Organic Liquids Document #: ...

  • Plan de Reducción de Emisiones de la Comunidad del Este de Oakland (CERP) Comité Directivo de la Comunidad #4 (CSC, por sus siglas en inglés)
    Plan de Reducción de Emisiones de la Comunidad del Este de Oakland (CERP) Comité Directivo de la Comunidad #4 (CSC, por sus siglas en inglés)

    dic. 16, 2022 ... Plan de Reducción de Emisiones de la Comunidad del Este de Oakland (CERP) Comité Directivo de la Comunidad #4 (CSC, por sus siglas en inglés) Diciembre 8, ...

    Read More
    (861 Kb PDF, 23 pgs)

    dic. 16, 2022 ... Plan de Reducción de Emisiones de la Comunidad del Este de Oakland (CERP) Comité Directivo de la Comunidad #4 (CSC, por sus siglas en inglés) Diciembre 8, ...

  • Copy of G07GMBP1Year 1RankList100710 4
    Copy of G07GMBP1Year 1RankList100710 4

    Oct 21, 2010 ... Proposition 1B: Goods Movement Emission Reduction Program Bay Area Trade Corridor Grant: G07GMBP1 Trucks Serving Ports and Intermodal Rail Yards (Main Grant) 10/07/2010 Solicitation Name: Year 1 ...

    Read More
    (1 Mb PDF, 20 pgs)

    Oct 21, 2010 ... Proposition 1B: Goods Movement Emission Reduction Program Bay Area Trade Corridor Grant: G07GMBP1 Trucks Serving Ports and Intermodal Rail Yards (Main Grant) 10/07/2010 Solicitation Name: Year 1 ...

  • 2008 Annual Report
    2008 Annual Report

    Jun 3, 2009 ... a nnual r eport Bay area Air Qu Ality Manage Ment ...

    Read More
    (673 Kb PDF, 16 pgs)

    Jun 3, 2009 ... a nnual r eport Bay area Air Qu Ality Manage Ment ...

  • Draft MRC Air Monitoring Plan (H2S revisions)
    Draft MRC Air Monitoring Plan (H2S revisions)

    Feb 14, 2023 ... Martinez Refining Company Regulation 12 Rule 15 Air Monitoring Plan ...

    Read More
    (1 Mb PDF, 29 pgs)

    Feb 14, 2023 ... Martinez Refining Company Regulation 12 Rule 15 Air Monitoring Plan ...

  • Guidebook
    Guidebook

    Jun 3, 2009 ... A Guide to the Bay area air Quality Manage Ment District Updated ...

    Read More
    (1 Mb PDF, 28 pgs)

    Jun 3, 2009 ... A Guide to the Bay area air Quality Manage Ment District Updated ...

  • Conoco Phillips FMP Update
    Conoco Phillips FMP Update

    Jun 23, 2009 ... San Francisco Refinery Rodeo, California BAAQMD Plant 16 Flare Minimization Plan (FMP) Non Confidential version Bay Area Air Quality Management District ...

    Read More
    (6 Mb PDF, 136 pgs)

    Jun 23, 2009 ... San Francisco Refinery Rodeo, California BAAQMD Plant 16 Flare Minimization Plan (FMP) Non Confidential version Bay Area Air Quality Management District ...

  • Air Quality Monitoring Modes
    Air Quality Monitoring Modes

    Jun 13, 2019 ... 6/13/2019 Air Quality Monitoring Modes Mode: Mobile Making measurements while in motion Fe at ur es : • Quickly screen for air pollutants over a broad spatial area • Multiple passes can reveal ...

    Read More
    (1 Mb PDF, 3 pgs)

    Jun 13, 2019 ... 6/13/2019 Air Quality Monitoring Modes Mode: Mobile Making measurements while in motion Fe at ur es : • Quickly screen for air pollutants over a broad spatial area • Multiple passes can reveal ...

  • Bayview Hunters Point/Comité Directivo Comunitario AB 617 del Sureste de San Francisco
    Bayview Hunters Point/Comité Directivo Comunitario AB 617 del Sureste de San Francisco

    may. 14, 2024 ... B a y v i e w H u n t e r s Po i n t / C o m i t é D i r e c t i v o C o m u n i t a r i o A B 6 1 7 d e l S u r e s t e d e S a n F ra n c i s c o R E S U ME N Martes, 16 de abril de 2024, de 5:00 ...

    Read More
    (217 Kb PDF, 4 pgs)

    may. 14, 2024 ... B a y v i e w H u n t e r s Po i n t / C o m i t é D i r e c t i v o C o m u n i t a r i o A B 6 1 7 d e l S u r e s t e d e S a n F ra n c i s c o R E S U ME N Martes, 16 de abril de 2024, de 5:00 ...

Spare the Air Status

Última actualización: 08/11/2016