|
|
|
|
|
125 results for 'span span span span span span span span'
Search: 'span span span span span span span span'
125 Search:
Jan 13, 2016 ... AIRE LIMPIO SESIONES ABIERTAS A LA COMUNIDAD El Distrito para el Control de la Calidad del Aire del Área de la Bahía le invita a par- Redwood City ticipar en una Sesión Abierta a la Comunidad ...
Read MoreJan 13, 2016 ... AIRE LIMPIO SESIONES ABIERTAS A LA COMUNIDAD El Distrito para el Control de la Calidad del Aire del Área de la Bahía le invita a par- Redwood City ticipar en una Sesión Abierta a la Comunidad ...
Oct 25, 2024 ... Belfort Model 6400 Visibility Sensor SOP, STI-6991 October 31, 2024 Version 3 Page 1 of 8 Standard Operating Procedures for the Belfort Model 6400 Visibility Sensor October 31, 2024 ...
Read MoreOct 25, 2024 ... Belfort Model 6400 Visibility Sensor SOP, STI-6991 October 31, 2024 Version 3 Page 1 of 8 Standard Operating Procedures for the Belfort Model 6400 Visibility Sensor October 31, 2024 ...
Manual of Procedures VOLUME V Continuous Emission Monitoring Policy and Procedures TABLE OF CONTENTS 1. Introduction 2. Applicability 3. Instrumentation 3. 1. General 3. 2. Specifications 3. 3. 4.
Read MoreManual of Procedures VOLUME V Continuous Emission Monitoring Policy and Procedures TABLE OF CONTENTS 1. Introduction 2. Applicability 3. Instrumentation 3. 1. General 3. 2. Specifications 3. 3. 4.
Dec 8, 2005 ... Source Test Procedure ST-34 BULK AND MARINE LOADING TERMINALS VAPOR RECOVERY UNITS (Adopted October 7, 1987) REF: Regulations 8-33-301, 308, 309, 8-6-302.1 and 8-44-301 1.
Read MoreDec 8, 2005 ... Source Test Procedure ST-34 BULK AND MARINE LOADING TERMINALS VAPOR RECOVERY UNITS (Adopted October 7, 1987) REF: Regulations 8-33-301, 308, 309, 8-6-302.1 and 8-44-301 1.
Sep 26, 1996 ... Source Test Procedure ST-3 BULK PLANTS EMISSION FACTOR DETERMINATION (Adopted January 20, 1982) REF: Regulation 8-6-301, 8-39-301 1. APPLICABILITY 1.1 This procedure is used to quantify the emission ...
Read MoreSep 26, 1996 ... Source Test Procedure ST-3 BULK PLANTS EMISSION FACTOR DETERMINATION (Adopted January 20, 1982) REF: Regulation 8-6-301, 8-39-301 1. APPLICABILITY 1.1 This procedure is used to quantify the emission ...
Oct 1, 1996 ... Source Test Procedure ST-21 TOTAL REDUCED SULFUR REF: Regulations 12-1-301 thru 303 1. APPLICABILITY 1.1 This method is used to quantify emissions of total reduced sulfur compounds (TRS) as H S, in ...
Read MoreOct 1, 1996 ... Source Test Procedure ST-21 TOTAL REDUCED SULFUR REF: Regulations 12-1-301 thru 303 1. APPLICABILITY 1.1 This method is used to quantify emissions of total reduced sulfur compounds (TRS) as H S, in ...
Sep 27, 1996 ... Source Test Procedure ST-13A OXIDES OF NITROGEN, CONTINUOUS SAMPLING REF: Regulations 9-3-301, 9-3-302, 10-1-301 1. APPLICABILITY 1.1 This method is used to quantify emissions of oxides of nitrogen.
Read MoreSep 27, 1996 ... Source Test Procedure ST-13A OXIDES OF NITROGEN, CONTINUOUS SAMPLING REF: Regulations 9-3-301, 9-3-302, 10-1-301 1. APPLICABILITY 1.1 This method is used to quantify emissions of oxides of nitrogen.
Sep 27, 1996 ... Source Test Procedure ST-19A SULFUR DIOXIDE, CONTINUOUS SAMPLING (Adopted January 20, 1982) REF: Regulations 9-1-302, 9-1-304 through 310, 10-1-301 1. APPLICABILITY 1.1 This method is used to ...
Read MoreSep 27, 1996 ... Source Test Procedure ST-19A SULFUR DIOXIDE, CONTINUOUS SAMPLING (Adopted January 20, 1982) REF: Regulations 9-1-302, 9-1-304 through 310, 10-1-301 1. APPLICABILITY 1.1 This method is used to ...
Oct 23, 2024 ... Synspec GC955 Hydrocarbon Analyzer SOP, STI-7984 Version 3 October 31, 2024 Page 1 of 27 Standard Operating Procedure for Synspec GC955 Hydrocarbon Analyzer October 31, 2024 STI-7984 ...
Read MoreOct 23, 2024 ... Synspec GC955 Hydrocarbon Analyzer SOP, STI-7984 Version 3 October 31, 2024 Page 1 of 27 Standard Operating Procedure for Synspec GC955 Hydrocarbon Analyzer October 31, 2024 STI-7984 ...
Jan 29, 2025 ... Docusign Envelope ID: 45F078F8-5BB4-471D-AF20-16B187D47AA6 Group A: Project Management and Data Quality Objectives QUALITY ASSURANCE PROJECT PLAN (QAPP) A1. Title Page Local-Scale ...
Read MoreJan 29, 2025 ... Docusign Envelope ID: 45F078F8-5BB4-471D-AF20-16B187D47AA6 Group A: Project Management and Data Quality Objectives QUALITY ASSURANCE PROJECT PLAN (QAPP) A1. Title Page Local-Scale ...
Quality Assurance Project Plan for the Chevron Richmond Refinery Fenceline Air Monitoring Program October 20, 2020 Revision ...
Read MoreQuality Assurance Project Plan for the Chevron Richmond Refinery Fenceline Air Monitoring Program October 20, 2020 Revision ...
Sep 9, 2010 ... West Oakland Monitoring Study DRAFT REPORT APPENDICES Sampling and Analytical Methods Prepared for: Bay Area Air Quality Management District 939 Ellis Street ...
Read MoreSep 9, 2010 ... West Oakland Monitoring Study DRAFT REPORT APPENDICES Sampling and Analytical Methods Prepared for: Bay Area Air Quality Management District 939 Ellis Street ...
Jul 11, 2022 ... PUBLIC WORKS DEPARTMENT PUBLIC SERVICES DIVISION 231 North Whisman Road, P.O. Box 7540 Mountain View, CA 94039-7540 650-903-6329 | MountainView.gov July 18, 2022 Mr. Jeffrey Gove, ...
Read MoreJul 11, 2022 ... PUBLIC WORKS DEPARTMENT PUBLIC SERVICES DIVISION 231 North Whisman Road, P.O. Box 7540 Mountain View, CA 94039-7540 650-903-6329 | MountainView.gov July 18, 2022 Mr. Jeffrey Gove, ...
May 26, 2021 ... Tri-Cities Recycling and Recovery Facility 7010 Auto Mall Parkway, Fremont, CA 94538 May 28, 2021 Director of Compliance and Enforcement Director of the Air Division Bay Area Air ...
Read MoreMay 26, 2021 ... Tri-Cities Recycling and Recovery Facility 7010 Auto Mall Parkway, Fremont, CA 94538 May 28, 2021 Director of Compliance and Enforcement Director of the Air Division Bay Area Air ...
Feb 9, 2024 ... SETTLEMENT AGREEMENT This Settlement Agreement (“Agreement”) is entered into as of February 12, 2024 (the “Effective Date”), by and between CHEVRON U.S.A. INC. (“Chevron”), a Pennsylvania ...
Read MoreFeb 9, 2024 ... SETTLEMENT AGREEMENT This Settlement Agreement (“Agreement”) is entered into as of February 12, 2024 (the “Effective Date”), by and between CHEVRON U.S.A. INC. (“Chevron”), a Pennsylvania ...
Jun 23, 2021 ... Corteva Agriscience 901 Loveridge Road Pittsburg, CA 94565 June 23, 2021 DELIVERED BY EMAIL: Compliance@BAAQMD.gov Jeff Gove Director of Enforcement Bay Area Air Quality Management District 375 ...
Read MoreJun 23, 2021 ... Corteva Agriscience 901 Loveridge Road Pittsburg, CA 94565 June 23, 2021 DELIVERED BY EMAIL: Compliance@BAAQMD.gov Jeff Gove Director of Enforcement Bay Area Air Quality Management District 375 ...
Jun 9, 2025 ... 1 PROPOSED SETTLEMENT AGREEMENT BY AND BETWEEN 2 THE BAY AREA AIR QUALITY MANAGMENT DISTRICT AND 3 CHEVRON PRODUCTS COMPANY (Notice of Violation 56287) 4 I. Background: Parties and ...
Read MoreJun 9, 2025 ... 1 PROPOSED SETTLEMENT AGREEMENT BY AND BETWEEN 2 THE BAY AREA AIR QUALITY MANAGMENT DISTRICT AND 3 CHEVRON PRODUCTS COMPANY (Notice of Violation 56287) 4 I. Background: Parties and ...
Sep 1, 2023 ... Fenceline Air Monitoring Plan For BAAQMD Rule 12-15 Chevron Richmond Refinery Revision 3 September 5, 2023 ...
Read MoreSep 1, 2023 ... Fenceline Air Monitoring Plan For BAAQMD Rule 12-15 Chevron Richmond Refinery Revision 3 September 5, 2023 ...
Dec 16, 2019 ... SCANNED 1 WZfi1 NOJ 21 AM Il: 2.~ . W"91'"£ MA,NAO.E~NT s I .' i l ! l : ! '( Tri-Cities Recycling and Recovery Facility 1~1 ¡· • , ~ I \ f \ t \ i ,, i: ' - I . 1.) - • I . -- ¡r. I 1 r A -.
Read MoreDec 16, 2019 ... SCANNED 1 WZfi1 NOJ 21 AM Il: 2.~ . W"91'"£ MA,NAO.E~NT s I .' i l ! l : ! '( Tri-Cities Recycling and Recovery Facility 1~1 ¡· • , ~ I \ f \ t \ i ,, i: ' - I . 1.) - • I . -- ¡r. I 1 r A -.
Huling Isinapanahon: 11/8/2016