The Air District is convening a community workgroup to inform development and implementation of our new Particle Fallout Sampling Program for refinery communities. We are looking for people who live or work near the Chevron, Marathon, MRC, Phillips 66, and Valero refineries, or who represent organizations and environmental groups that serve these communities.
Read MoreThe Air District is convening a community workgroup to inform development and implementation of our new Particle Fallout Sampling Program for refinery communities. We are looking for people who live or work near the Chevron, Marathon, MRC, Phillips 66, and Valero refineries, or who represent organizations and environmental groups that serve these communities.
Oct 1, 1996 ... Source Test Procedure ST-23 WATER VAPOR (Adopted January 20, 1982) 1. APPLICABILITY 1.1 This method is used to quantify the water vapor content of stack gases. It is applicable in all cases in which ...
Read MoreOct 1, 1996 ... Source Test Procedure ST-23 WATER VAPOR (Adopted January 20, 1982) 1. APPLICABILITY 1.1 This method is used to quantify the water vapor content of stack gases. It is applicable in all cases in which ...
Oct 1, 1996 ... Source Test Procedure ST-22 TRIMETHYLAMINE (Adopted January 20, 1982) REF: Regulation 7-303 1. APPLICABILITY 1.1 This method is used to quantify emissions of Trimethylamine (TMA). It determines ...
Read MoreOct 1, 1996 ... Source Test Procedure ST-22 TRIMETHYLAMINE (Adopted January 20, 1982) REF: Regulation 7-303 1. APPLICABILITY 1.1 This method is used to quantify emissions of Trimethylamine (TMA). It determines ...
Jan 18, 2018 ... Sampling Study Protocol Specifications for Third-Party Verifiers Fugitive Emissions from Petroleum Refinery Equipment in Heavy Liquid Service Joint Study between the Bay Area Air ...
Read MoreJan 18, 2018 ... Sampling Study Protocol Specifications for Third-Party Verifiers Fugitive Emissions from Petroleum Refinery Equipment in Heavy Liquid Service Joint Study between the Bay Area Air ...
Sep 26, 1996 ... Source Test Procedure ST-2 BERYLLIUM (Adopted January 20, 1982) REF: Regulation 11-3-301 1. APPLICABILITY 1.1 This procedure is used to quantify emissions of Beryllium. It determines compliance with ...
Read MoreSep 26, 1996 ... Source Test Procedure ST-2 BERYLLIUM (Adopted January 20, 1982) REF: Regulation 11-3-301 1. APPLICABILITY 1.1 This procedure is used to quantify emissions of Beryllium. It determines compliance with ...
十月 1, 1996 ... Source Test Procedure ST-32 ETHANOL, INTEGRATED SAMPLING (Adopted December 21, 1988) REF: Regulation 8, Rule 42 1. APPLICABILITY 1.1 This procedure is used to quantify emissions of ethanol. It ...
Read More十月 1, 1996 ... Source Test Procedure ST-32 ETHANOL, INTEGRATED SAMPLING (Adopted December 21, 1988) REF: Regulation 8, Rule 42 1. APPLICABILITY 1.1 This procedure is used to quantify emissions of ethanol. It ...
May 6, 2016 ... MOP Vol. IX Procedure – P‐1 Volatile Organic Compounds Water Sampling PROCEDURE - 1 ORGANIC COMPOUNDS WATER SAMPLING REF: Regulation 11-10 1. APPLICABILITY 1.1 This procedure is used to ...
Read MoreMay 6, 2016 ... MOP Vol. IX Procedure – P‐1 Volatile Organic Compounds Water Sampling PROCEDURE - 1 ORGANIC COMPOUNDS WATER SAMPLING REF: Regulation 11-10 1. APPLICABILITY 1.1 This procedure is used to ...
Sep 27, 1996 ... Source Test Procedure ST-14 OXYGEN, CONTINUOUS SAMPLING Adopted January 20, 1982 REF: Regulations 9-3-301, 9-3-302 1. APPLICABILITY 1.1 This method is used to quantify emissions of oxygen. It ...
Read MoreSep 27, 1996 ... Source Test Procedure ST-14 OXYGEN, CONTINUOUS SAMPLING Adopted January 20, 1982 REF: Regulations 9-3-301, 9-3-302 1. APPLICABILITY 1.1 This method is used to quantify emissions of oxygen. It ...
Oct 7, 1996 ... Source Test Method ST-16 PHENOLIC COMPOUNDS (Adopted January 20, 1982) REF: Regulation 7-303 1. APPLICABILITY 1.1 This method is used to quantify emissions of phenolic compounds as phenol. It is ...
Read MoreOct 7, 1996 ... Source Test Method ST-16 PHENOLIC COMPOUNDS (Adopted January 20, 1982) REF: Regulation 7-303 1. APPLICABILITY 1.1 This method is used to quantify emissions of phenolic compounds as phenol. It is ...
Sep 27, 1996 ... Source Test Method ST-11 MERCAPTANS Adopted (January 20, 1982) REF: Regulation 7-303 1. APPLICABILITY 1.1 This method is used to determine emissions of mercaptans. It is applicable to the ...
Read MoreSep 27, 1996 ... Source Test Method ST-11 MERCAPTANS Adopted (January 20, 1982) REF: Regulation 7-303 1. APPLICABILITY 1.1 This method is used to determine emissions of mercaptans. It is applicable to the ...
Sep 27, 1996 ... Source Test Method ST-15 PARTICULATE (Adopted January 20, 1982) REF: Regulations 6-310, 6-311, 10-1-301 1. APPLICABILITY 1.1 This method is used to quantify particulate emissions. It ...
Read MoreSep 27, 1996 ... Source Test Method ST-15 PARTICULATE (Adopted January 20, 1982) REF: Regulations 6-310, 6-311, 10-1-301 1. APPLICABILITY 1.1 This method is used to quantify particulate emissions. It ...
Oct 1, 1996 ... Source Test Procedure ST-28 HYDROGEN SULFIDE, INTEGRATED SAMPLING (Adopted January 20, 1982) REF. Regulation 10-8-303 1. APPLICABILITY 1.1 This method is applicable for the determination of hydrogen ...
Read MoreOct 1, 1996 ... Source Test Procedure ST-28 HYDROGEN SULFIDE, INTEGRATED SAMPLING (Adopted January 20, 1982) REF. Regulation 10-8-303 1. APPLICABILITY 1.1 This method is applicable for the determination of hydrogen ...
Sep 27, 1996 ... Source Test Procedure ST-5 CARBON DIOXIDE, CONTINUOUS SAMPLING REF: Regulation 6-310.1 1. APPLICABILITY 1.1 This method is used to quantify emissions of carbon dioxide. It determines compliance ...
Read MoreSep 27, 1996 ... Source Test Procedure ST-5 CARBON DIOXIDE, CONTINUOUS SAMPLING REF: Regulation 6-310.1 1. APPLICABILITY 1.1 This method is used to quantify emissions of carbon dioxide. It determines compliance ...
Oct 1, 1996 ... Source Test Procedure ST-21 TOTAL REDUCED SULFUR REF: Regulations 12-1-301 thru 303 1. APPLICABILITY 1.1 This method is used to quantify emissions of total reduced sulfur compounds (TRS) as H S, in ...
Read MoreOct 1, 1996 ... Source Test Procedure ST-21 TOTAL REDUCED SULFUR REF: Regulations 12-1-301 thru 303 1. APPLICABILITY 1.1 This method is used to quantify emissions of total reduced sulfur compounds (TRS) as H S, in ...
Oct 10, 2017 ... October 10, 2017 Request for Qualifications #2017-015 Air Sampling Network Maintenance and Operations SECTION I – SUMMARY ...
Read MoreOct 10, 2017 ... October 10, 2017 Request for Qualifications #2017-015 Air Sampling Network Maintenance and Operations SECTION I – SUMMARY ...
Sep 27, 1996 ... Source Test Procedure ST-6 CARBON MONOXIDE, CONTINUOUS SAMPLING REF: Regulation 8-1-110.3, 10-8-301 1. APPLICABILITY 1.1 This method is used to quantify emissions of carbon monoxide (CO).
Read MoreSep 27, 1996 ... Source Test Procedure ST-6 CARBON MONOXIDE, CONTINUOUS SAMPLING REF: Regulation 8-1-110.3, 10-8-301 1. APPLICABILITY 1.1 This method is used to quantify emissions of carbon monoxide (CO).
Oct 1, 1996 ... Source Test Procedure ST-24 TANK SAMPLING FOR ORSAT ANALYSIS (CO, CO , O ) 2 2 REF: Regulations 6-310.1, 8-1-110.3, 10-3-301, 9-3-301 through 9-3-304 1. APPLICABILITY 1.1 This procedure is used to ...
Read MoreOct 1, 1996 ... Source Test Procedure ST-24 TANK SAMPLING FOR ORSAT ANALYSIS (CO, CO , O ) 2 2 REF: Regulations 6-310.1, 8-1-110.3, 10-3-301, 9-3-301 through 9-3-304 1. APPLICABILITY 1.1 This procedure is used to ...
Aug 27, 2013 ... Guidelines for Construction of Particulate Sampling and Testing Facilities Introduction Selection of a proper sampling site is vital to assure representative measurement of pollutant ...
Read MoreAug 27, 2013 ... Guidelines for Construction of Particulate Sampling and Testing Facilities Introduction Selection of a proper sampling site is vital to assure representative measurement of pollutant ...
Oct 1, 1996 ... BAY AREA AIR QUALITY MANAGEMENT DISTRICT Manual of Procedures Volume IV Source Test Policy and ...