火炬

BAAQMD Refinery Flare Emission Report
Report Settings
Chevron Richmond - Hydrogen H2
Download CSV
六月 - 2025
Date Vent Gas Flow Methane NMHC Sulfur Dioxide
(mo/day/yr) (volume in scf) See notes 6,7 (lbs) (lbs) (lbs)
6/1/2025 171,469.23 85.81 13.54 0.38
6/2/2025 163,606.89 83.41 12.89 0.36
6/3/2025 171,398.19 86.70 13.27 0.39
6/4/2025 163,141.03 81.32 11.70 0.35
6/5/2025 138,985.29 70.84 9.92 0.31
6/6/2025 931,366.40 188.97 346.52 6.44
6/7/2025 261,030.97 70.13 20.28 0.48
6/8/2025 121,539.92 60.34 9.99 0.30
6/9/2025 110,253.91 54.20 9.70 0.27
6/10/2025 120,978.43 58.44 11.62 0.30
6/11/2025 125,831.53 61.20 11.47 0.30
6/12/2025 172,339.46 79.61 41.77 0.82
6/13/2025 143,910.13 69.44 12.63 0.44
6/14/2025 128,227.84 63.85 10.13 0.34
6/15/2025 221,034.30 85.97 21.72 0.64
6/16/2025 110,487.26 56.82 9.04 0.27
6/17/2025 134,006.91 70.02 11.08 0.32
6/18/2025 137,623.45 71.57 11.75 0.32
6/19/2025 135,984.94 70.07 11.56 0.31
6/20/2025 137,760.75 71.65 12.93 0.32
6/21/2025 113,058.47 57.43 11.09 0.27
6/22/2025 132,589.09 65.15 12.47 0.32
6/23/2025 180,215.03 85.39 18.40 0.46
6/24/2025 168,858.80 81.08 15.76 0.41
6/25/2025 162,739.66 80.31 13.85 0.37
6/26/2025 155,058.49 76.57 12.35 0.35
6/27/2025 159,163.28 80.28 11.97 0.35
6/28/2025 159,053.65 78.81 12.34 0.35
6/29/2025 176,744.27 87.05 13.77 0.39
6/30/2025 174,805.66 86.46 14.02 0.39
六月 Totals 5,383,263.23 2,318.89 749.53 17.32
  • (1) Sample(s) collected during release event used to calculate emissions
    (2) No sample collected during release event. Used another sample from the same day
    (3) No sample collected during release event. Used mass spec composition data.
    (4) No sample collected during release event. Used another representative sample based on engineering judgment.
    (5) No sample collected during release event. Used 12-month rolling emission factor based on the flaring events > 1 MMSCFD
    (6) No sample collected during release event. Used 12-month rolling emission factor
    (7) Negative meter noise overwritten as zero.
    (8) Positive meter noise <0.5 ft/sec="" overwritten="" as="">
    (9) Removed raw readings > 0.5 ft/sec that did NOT represent real flow to flare. Monitoring indicates vent gas pressure was not sufficient to break water seal.
    (10) Vent gas volume based on engineering judgment during periods of monitor inoperation
Chevron Richmond Hydrogen H2 Flare Report 6/1/2025 - 6/30/2025
 
 

Contact Us


一般資訊

415 749-4900


空氣監測

415 749-4985

Contact Us

Spare the Air Status

Last Updated: 2023/8/3