搜尋

  • 2/04/2009 - Dib, Fadi
    2/04/2009 - Dib, Fadi

    Feb 24, 2009 ... Page 1 of 1 From: Weyman Lee Sent: Monday, February 23, 2009 10:54 AM Vanessa Hodgson To: Subject: FW: Permit for the Russell City Energy Center -----Original Message----- From: Fadi Dib ...

    Read More
    (9 Kb PDF, 1 pg)

    Feb 24, 2009 ... Page 1 of 1 From: Weyman Lee Sent: Monday, February 23, 2009 10:54 AM Vanessa Hodgson To: Subject: FW: Permit for the Russell City Energy Center -----Original Message----- From: Fadi Dib ...

  • Proposed amendments to Regulation 2, Rule 5
    Proposed amendments to Regulation 2, Rule 5

    Oct 27, 2009 ... DRAFT – DO NOT CITE OR QUOTE – DRAFT October 20, 2009 REGULATION 2 PERMITS RULE 5 NEW SOURCE REVIEW OF TOXIC AIR CONTAMINANTS INDEX 2-5-100 GENERAL 2-5-101 Description 2-5-110 Exemption, Low ...

    Read More
    (1 Mb PDF, 26 pgs)

    Oct 27, 2009 ... DRAFT – DO NOT CITE OR QUOTE – DRAFT October 20, 2009 REGULATION 2 PERMITS RULE 5 NEW SOURCE REVIEW OF TOXIC AIR CONTAMINANTS INDEX 2-5-100 GENERAL 2-5-101 Description 2-5-110 Exemption, Low ...

  • Appendix A
    Appendix A

    Feb 16, 2012 ... APPENDIX A EMISSIONS INVENTORY The development of an emissions inventory requires information on the emission rates for an activity (i.e., the expected emissions for a given unit or volume of ...

    Read More
    (57 Kb PDF, 9 pgs)

    Feb 16, 2012 ... APPENDIX A EMISSIONS INVENTORY The development of an emissions inventory requires information on the emission rates for an activity (i.e., the expected emissions for a given unit or volume of ...

  • Staff Report including Appendices Posted December 11, 2009
    Staff Report including Appendices Posted December 11, 2009

    Nov 30, 2009 ... RULE DEVELOPMENT STAFF REPORT DECEMBER 2009 Proposed Amendments to: Regulation 2: Permits, Rule 5: New Source Review of Toxic Air Contaminants Carol Allen, ...

    Read More
    (7 Mb PDF, 204 pgs)

    Nov 30, 2009 ... RULE DEVELOPMENT STAFF REPORT DECEMBER 2009 Proposed Amendments to: Regulation 2: Permits, Rule 5: New Source Review of Toxic Air Contaminants Carol Allen, ...

  • Engineering Evaluation
    Engineering Evaluation

    Dec 11, 2012 ... SYNTHETIC MINOR OPERATING PERMIT EVALUATION REPORT Genentech, Inc. Plant Number: A1257 Application Number: 24594 BACKGROUND Genentech, Inc. (Genentech) is subject to the ...

    Read More
    (1 Mb PDF, 30 pgs)

    Dec 11, 2012 ... SYNTHETIC MINOR OPERATING PERMIT EVALUATION REPORT Genentech, Inc. Plant Number: A1257 Application Number: 24594 BACKGROUND Genentech, Inc. (Genentech) is subject to the ...

  • Engineering Evaluation
    Engineering Evaluation

    May 14, 2012 ... SYNTHETIC MINOR OPERATING PERMIT EVALUATION REPORT Hitachi Global Storage Technologies Inc. Plant Number: A0085 Application Number: 24185 BACKGROUND Hitachi Global Storage ...

    Read More
    (670 Kb PDF, 21 pgs)

    May 14, 2012 ... SYNTHETIC MINOR OPERATING PERMIT EVALUATION REPORT Hitachi Global Storage Technologies Inc. Plant Number: A0085 Application Number: 24185 BACKGROUND Hitachi Global Storage ...

  • 30768 Permit Evaluation Appendix A-G
    30768 Permit Evaluation Appendix A-G

    Jul 20, 2022 ... Appendix A – Marathon Martinez Fuel Gas System Fuel Gas System – Overview The existing Fuel Gas system includes gases produced in the No. 5 Gas Plant (S-1526) and No. 4 Gas Plant (S-955 through ...

    Read More
    (3 Mb PDF, 107 pgs)

    Jul 20, 2022 ... Appendix A – Marathon Martinez Fuel Gas System Fuel Gas System – Overview The existing Fuel Gas system includes gases produced in the No. 5 Gas Plant (S-1526) and No. 4 Gas Plant (S-955 through ...

  • 421921 Permit Evaluation
    421921 Permit Evaluation

    Sep 13, 2017 ... DRAFT ENGINEERING EVALUATION Facility ID No. 1148 Coit Services Incorporated 897 Hinckley Road, Burlingame, CA 94010 Application No. 421921 Background Coit Services Incorporated is ...

    Read More
    (273 Kb PDF, 8 pgs)

    Sep 13, 2017 ... DRAFT ENGINEERING EVALUATION Facility ID No. 1148 Coit Services Incorporated 897 Hinckley Road, Burlingame, CA 94010 Application No. 421921 Background Coit Services Incorporated is ...

  • 27278 Permit Evaluation
    27278 Permit Evaluation

    Jul 31, 2015 ... DRAFT ENGINEERING EVALUATION Linden Residence Application No. 27278 Plant No. 23128 BACKGROUND Linden Residence has applied for an Authority to Construct (AC) and/or Permit to Operate for ...

    Read More
    (335 Kb PDF, 8 pgs)

    Jul 31, 2015 ... DRAFT ENGINEERING EVALUATION Linden Residence Application No. 27278 Plant No. 23128 BACKGROUND Linden Residence has applied for an Authority to Construct (AC) and/or Permit to Operate for ...

  • 30580 Permit Evaluation
    30580 Permit Evaluation

    Sep 9, 2020 ... Draft ENGINEERING EVALUATION Alameda County GSA Plant 13908 | Application 30580 1401 Lakeside Dr, Oakland, CA 94612 BACKGROUND Alameda County has applied for an Authority to Construct and a ...

    Read More
    (240 Kb PDF, 6 pgs)

    Sep 9, 2020 ... Draft ENGINEERING EVALUATION Alameda County GSA Plant 13908 | Application 30580 1401 Lakeside Dr, Oakland, CA 94612 BACKGROUND Alameda County has applied for an Authority to Construct and a ...

  • 28064 Permit Evaluation
    28064 Permit Evaluation

    Oct 7, 2016 ... Engineering Evaluation Andronico’s Community Markets Application No. 28064 Plant No. 23618 690 Fremont Avenue, Los Altos, CA 94024 BACKGROUND Andronico’s Community Markets has applied ...

    Read More
    (634 Kb PDF, 6 pgs)

    Oct 7, 2016 ... Engineering Evaluation Andronico’s Community Markets Application No. 28064 Plant No. 23618 690 Fremont Avenue, Los Altos, CA 94024 BACKGROUND Andronico’s Community Markets has applied ...

  • 31181 Permit Evaluation
    31181 Permit Evaluation

    Dec 8, 2021 ... Engineering Evaluation PG&E Generator Enhancement Daly City 3004 Geneva Ave, Daly City, CA 94014 Application No. 31181 Plant No. 14159 BACKGROUND Pacific Gas and Electric has applied for ...

    Read More
    (449 Kb PDF, 10 pgs)

    Dec 8, 2021 ... Engineering Evaluation PG&E Generator Enhancement Daly City 3004 Geneva Ave, Daly City, CA 94014 Application No. 31181 Plant No. 14159 BACKGROUND Pacific Gas and Electric has applied for ...

  • 712408 Permit Evaluation
    712408 Permit Evaluation

    Mar 4, 2025 ... ENGINEERING EVALUATION Facility ID No. 20829 Ensign Sonoma Healthcare Center 1250 Broadway Avenue, Sonoma, CA 95476 Application No. 712408 Background Ensign Sonoma Healthcare Center ...

    Read More
    (273 Kb PDF, 11 pgs)

    Mar 4, 2025 ... ENGINEERING EVALUATION Facility ID No. 20829 Ensign Sonoma Healthcare Center 1250 Broadway Avenue, Sonoma, CA 95476 Application No. 712408 Background Ensign Sonoma Healthcare Center ...

  • Permit Evaluation
    Permit Evaluation

    Jul 3, 2014 ... DRAFT ENGINEERING EVALUATION 32 Shady Lane Application No. 26281 Plant No. 22443 BACKGROUND 32 Shady Lane has applied for an Authority to Construct (AC) and/or Permit to Operate for the ...

    Read More
    (668 Kb PDF, 8 pgs)

    Jul 3, 2014 ... DRAFT ENGINEERING EVALUATION 32 Shady Lane Application No. 26281 Plant No. 22443 BACKGROUND 32 Shady Lane has applied for an Authority to Construct (AC) and/or Permit to Operate for the ...

  • 28260 Permit Evaluation
    28260 Permit Evaluation

    Feb 28, 2017 ... Application #28260 Page 1 of 7 Engineering Evaluation Thompson Suskind, L.P. Application No. 28260 Plant No. 23714 38 Fernhill Avenue, Ross, CA 94957 BACKGROUND Thompson Suskind, ...

    Read More
    (477 Kb PDF, 7 pgs)

    Feb 28, 2017 ... Application #28260 Page 1 of 7 Engineering Evaluation Thompson Suskind, L.P. Application No. 28260 Plant No. 23714 38 Fernhill Avenue, Ross, CA 94957 BACKGROUND Thompson Suskind, ...

  • 23788 Permit Evaluation
    23788 Permit Evaluation

    May 24, 2012 ... Application #23788 Page 1 of 5 DRAFT Engineering Evaluation Leisure Home Mobile Home Application No. 23788 Plant No. 20958 2185 Occidental Road, Santa Rosa, CA 95401 BACKGROUND ...

    Read More
    (199 Kb PDF, 5 pgs)

    May 24, 2012 ... Application #23788 Page 1 of 5 DRAFT Engineering Evaluation Leisure Home Mobile Home Application No. 23788 Plant No. 20958 2185 Occidental Road, Santa Rosa, CA 95401 BACKGROUND ...

  • 25614 Permit Evaluation
    25614 Permit Evaluation

    Nov 18, 2013 ... Engineering Evaluation New Cingular Wireless PCS, LLC dba AT&T Mobility Application No. 25614 Plant No. 22040 650 East Blithedale Avenue, Mill Valley, CA 94941 BACKGROUND New Cingular ...

    Read More
    (252 Kb PDF, 5 pgs)

    Nov 18, 2013 ... Engineering Evaluation New Cingular Wireless PCS, LLC dba AT&T Mobility Application No. 25614 Plant No. 22040 650 East Blithedale Avenue, Mill Valley, CA 94941 BACKGROUND New Cingular ...

  • 28585 Permit Evaluation
    28585 Permit Evaluation

    Mar 1, 2018 ... DRAFT ENGINEERING EVALUATION Residence Betsy Ellis Chung, Plant No. 23861 Application No. 28585 Residence Betsy Ellis Chung Ave, Hillsborough, CA A. BACKGROUND An application for a ...

    Read More
    (397 Kb PDF, 10 pgs)

    Mar 1, 2018 ... DRAFT ENGINEERING EVALUATION Residence Betsy Ellis Chung, Plant No. 23861 Application No. 28585 Residence Betsy Ellis Chung Ave, Hillsborough, CA A. BACKGROUND An application for a ...

  • 26822 Permit Evaluation
    26822 Permit Evaluation

    Apr 15, 2015 ... Application #26822 Page 1 of 5 Engineering Evaluation Safeway, Inc. Application No. 26822 Plant No. 22814 3970 Rivermark Plaza, Santa Clara, CA 95054 BACKGROUND Safeway, Inc. has ...

    Read More
    (361 Kb PDF, 5 pgs)

    Apr 15, 2015 ... Application #26822 Page 1 of 5 Engineering Evaluation Safeway, Inc. Application No. 26822 Plant No. 22814 3970 Rivermark Plaza, Santa Clara, CA 95054 BACKGROUND Safeway, Inc. has ...

  • 30883 Permit Evaluation
    30883 Permit Evaluation

    Apr 14, 2021 ... Plant # 24847 Application # 30883 Page 1 of 6 Engineering Evaluation Regusci Residence Application No. 30883 / Plant No. 24847 1745 Stockton Street, Saint Helena, CA 94574 BACKGROUND ...

    Read More
    (240 Kb PDF, 6 pgs)

    Apr 14, 2021 ... Plant # 24847 Application # 30883 Page 1 of 6 Engineering Evaluation Regusci Residence Application No. 30883 / Plant No. 24847 1745 Stockton Street, Saint Helena, CA 94574 BACKGROUND ...

Spare the Air Status