Advisory
|
The public comment period for Permit Application #704470 (CA-002 Somo Village) has been extended and will now end on October 3, 2025. Please visit our Public Notices page for more information.
The public comment period for Permit Application #704470 (CA-002 Somo Village) has been extended and will now end on October 3, 2025. Please visit our Public Notices page for more information.
|
130 results for 'sampling sampling'
Search: 'sampling sampling'
130 Search:
Sep 27, 1996 ... Source Test Procedure ST-13A OXIDES OF NITROGEN, CONTINUOUS SAMPLING REF: Regulations 9-3-301, 9-3-302, 10-1-301 1. APPLICABILITY 1.1 This method is used to quantify emissions of oxides of nitrogen.
Read MoreSep 27, 1996 ... Source Test Procedure ST-13A OXIDES OF NITROGEN, CONTINUOUS SAMPLING REF: Regulations 9-3-301, 9-3-302, 10-1-301 1. APPLICABILITY 1.1 This method is used to quantify emissions of oxides of nitrogen.
Sep 27, 1996 ... Source Test Procedure ST-19B TOTAL SULFUR OXIDES, INTEGRATED SAMPLE REF: Regulations 9-1-302, 9-1-304 through 310, 10-1-301 1. APPLICABILITY 1.1 This method is used to quantify emissions of total ...
Read MoreSep 27, 1996 ... Source Test Procedure ST-19B TOTAL SULFUR OXIDES, INTEGRATED SAMPLE REF: Regulations 9-1-302, 9-1-304 through 310, 10-1-301 1. APPLICABILITY 1.1 This method is used to quantify emissions of total ...
Oct 1, 1996 ... Source Test Procedure ST-24 TANK SAMPLING FOR ORSAT ANALYSIS (CO, CO , O ) 2 2 REF: Regulations 6-310.1, 8-1-110.3, 10-3-301, 9-3-301 through 9-3-304 1. APPLICABILITY 1.1 This procedure is used to ...
Read MoreOct 1, 1996 ... Source Test Procedure ST-24 TANK SAMPLING FOR ORSAT ANALYSIS (CO, CO , O ) 2 2 REF: Regulations 6-310.1, 8-1-110.3, 10-3-301, 9-3-301 through 9-3-304 1. APPLICABILITY 1.1 This procedure is used to ...
Aug 27, 2013 ... Guidelines for Construction of Particulate Sampling and Testing Facilities Introduction Selection of a proper sampling site is vital to assure representative measurement of pollutant ...
Read MoreAug 27, 2013 ... Guidelines for Construction of Particulate Sampling and Testing Facilities Introduction Selection of a proper sampling site is vital to assure representative measurement of pollutant ...
Oct 1, 1996 ... BAY AREA AIR QUALITY MANAGEMENT DISTRICT Manual of Procedures Volume IV Source Test Policy and ...
Read MoreOct 1, 1996 ... BAY AREA AIR QUALITY MANAGEMENT DISTRICT Manual of Procedures Volume IV Source Test Policy and ...
jun. 1, 2022 ... Compliance Advisory June 9, 2022 Source Testing and Emissions Monitoring Advisory This Compliance Advisory is provided to inform you about activities of the Air District which may affect your ...
Read Morejun. 1, 2022 ... Compliance Advisory June 9, 2022 Source Testing and Emissions Monitoring Advisory This Compliance Advisory is provided to inform you about activities of the Air District which may affect your ...
May 21, 2012 ... Facility Name: SFPP. L.P. San Jose Terminal #: A4020 Permit for Facility Page #l through April 30,2012 Report for Period November 1,201l Title V Monitoring Verifìcation Semi-Annual Table VII - ...
Read MoreMay 21, 2012 ... Facility Name: SFPP. L.P. San Jose Terminal #: A4020 Permit for Facility Page #l through April 30,2012 Report for Period November 1,201l Title V Monitoring Verifìcation Semi-Annual Table VII - ...
May 21, 2012 ... Facility Name: SFPP, L.P. Concord Station Permit for Facility #: A4022 Page #l for Period ll/0llll through 4/30/12 Title V Semi-Annual Monitoring Verification Report Appricabre Limirs ...
Read MoreMay 21, 2012 ... Facility Name: SFPP, L.P. Concord Station Permit for Facility #: A4022 Page #l for Period ll/0llll through 4/30/12 Title V Semi-Annual Monitoring Verification Report Appricabre Limirs ...
Jan 24, 2022 ... PUBLIC VERSION 1 -WITHOUT TRADE SECRETS 2 3 FILED 4 I JAl'l2 4 2022 5 HEARING BOARD BEFORE IBE HEARING BOARD OF THE BAY AREA AIR OUAU1Y 6 MANAOEMENT DISTRICT BAY AREA AIR QUALITY ...
Read MoreJan 24, 2022 ... PUBLIC VERSION 1 -WITHOUT TRADE SECRETS 2 3 FILED 4 I JAl'l2 4 2022 5 HEARING BOARD BEFORE IBE HEARING BOARD OF THE BAY AREA AIR OUAU1Y 6 MANAOEMENT DISTRICT BAY AREA AIR QUALITY ...
oct. 1, 1996 ... Source Test Method ST-35 TOTAL AND HEXAVALENT CHROME (Adopted January 18, 1989) REF: Regulations 11-8-301, 310, 330 1. APPLICABILITY 1.1 This method is used to quantify total and hexavalent chromium ...
Read Moreoct. 1, 1996 ... Source Test Method ST-35 TOTAL AND HEXAVALENT CHROME (Adopted January 18, 1989) REF: Regulations 11-8-301, 310, 330 1. APPLICABILITY 1.1 This method is used to quantify total and hexavalent chromium ...
Jul 9, 2013 ... Review of Current Air Monitoring Capabilities near Refineries in the San Francisco Bay Area Final Report Prepared for: Bay Area Air Quality Management District ...
Read MoreJul 9, 2013 ... Review of Current Air Monitoring Capabilities near Refineries in the San Francisco Bay Area Final Report Prepared for: Bay Area Air Quality Management District ...
May 26, 2021 ... REDWOOD LANDFILL, INC. P.O. Box 793 8950 Redwood Highway Novato, CA 94948 (415) 892-2851 (415) 898-1354 Fax May 27, 2021 Director of Compliance and Enforcement Director of the Air ...
Read MoreMay 26, 2021 ... REDWOOD LANDFILL, INC. P.O. Box 793 8950 Redwood Highway Novato, CA 94948 (415) 892-2851 (415) 898-1354 Fax May 27, 2021 Director of Compliance and Enforcement Director of the Air ...
Nov 16, 2004 ... Bay Area Air Quality Management District 939 Ellis Street San Francisco, CA 94109 (415) 771-6000 Final MAJOR FACILITY REVIEW PERMIT Issued To: Central Contra Costa Sanitary ...
Read MoreNov 16, 2004 ... Bay Area Air Quality Management District 939 Ellis Street San Francisco, CA 94109 (415) 771-6000 Final MAJOR FACILITY REVIEW PERMIT Issued To: Central Contra Costa Sanitary ...
Jul 14, 1999 ... Bay Area Air Quality Management District 939 Ellis Street San Francisco, CA 94109 (415) 771-6000 Final MAJOR FACILITY REVIEW PERMIT Issued To: Cardinal Cogen Facility #A1629 Facility Address: Campus ...
Read MoreJul 14, 1999 ... Bay Area Air Quality Management District 939 Ellis Street San Francisco, CA 94109 (415) 771-6000 Final MAJOR FACILITY REVIEW PERMIT Issued To: Cardinal Cogen Facility #A1629 Facility Address: Campus ...
May 2, 2025 ... May 12, 2025 Director of Compliance and Enforcement Bay Area Air Quality Management District 375 Beale St, Suite 600 San Francisco, CA 94105 Attn: Title V Reports Electronic Submittal Subject: ...
Read MoreMay 2, 2025 ... May 12, 2025 Director of Compliance and Enforcement Bay Area Air Quality Management District 375 Beale St, Suite 600 San Francisco, CA 94105 Attn: Title V Reports Electronic Submittal Subject: ...
Jul 10, 2001 ... Bay Area Air Quality Management District 939 Ellis Street San Francisco, CA 94109 (415) 771-6000 Final MAJOR FACILITY REVIEW PERMIT Issued To: Jefferson Smurfit Corporation Facility #A0732 Facility ...
Read MoreJul 10, 2001 ... Bay Area Air Quality Management District 939 Ellis Street San Francisco, CA 94109 (415) 771-6000 Final MAJOR FACILITY REVIEW PERMIT Issued To: Jefferson Smurfit Corporation Facility #A0732 Facility ...
May 23, 2016 ... METEOROLOGY, MEASUREMENT AND RULES DIVISION 2015 AIR MONITORING NETWORK PLAN July 1, 2016 Charles Knoderer Duc Nguyen Dan Alrick and Katherine Hoag Meteorology, Measurements and ...
Read MoreMay 23, 2016 ... METEOROLOGY, MEASUREMENT AND RULES DIVISION 2015 AIR MONITORING NETWORK PLAN July 1, 2016 Charles Knoderer Duc Nguyen Dan Alrick and Katherine Hoag Meteorology, Measurements and ...
Sep 22, 2006 ... Bay Area Air Quality Management District 939 Ellis Street San Francisco, CA 94109 (415) 771-6000 D D D Proposed r MAJOR FACILITY REVIEW PERMIT r r Issued To: Central Contra Costa ...
Read MoreSep 22, 2006 ... Bay Area Air Quality Management District 939 Ellis Street San Francisco, CA 94109 (415) 771-6000 D D D Proposed r MAJOR FACILITY REVIEW PERMIT r r Issued To: Central Contra Costa ...
Última actualización: 08/11/2016