|
209 results for '198857 7'
Search: '198857 7'
209 Search:
Jul 19, 2022 ... July 21, 2022 Mr. Gerardo Rios Permits Office Chief United States Environmental Protection Agency Region 9 Air-3-1 75 Hawthorne Street San Francisco, CA 94105 Dear Mr. Rios: ...
Read MoreJul 19, 2022 ... July 21, 2022 Mr. Gerardo Rios Permits Office Chief United States Environmental Protection Agency Region 9 Air-3-1 75 Hawthorne Street San Francisco, CA 94105 Dear Mr. Rios: ...
Oct 1, 1996 ... Source Test Procedure ST-22 TRIMETHYLAMINE (Adopted January 20, 1982) REF: Regulation 7-303 1. APPLICABILITY 1.1 This method is used to quantify emissions of Trimethylamine (TMA). It determines ...
Read MoreOct 1, 1996 ... Source Test Procedure ST-22 TRIMETHYLAMINE (Adopted January 20, 1982) REF: Regulation 7-303 1. APPLICABILITY 1.1 This method is used to quantify emissions of Trimethylamine (TMA). It determines ...
Mar 25, 2008 ... DRAFT 3-18-2008 REGULATION 9 INORGANIC GASEOUS POLLUTANTS RULE 7 NITROGEN OXIDES AND CARBON MONOXIDE FROM INDUSTRIAL, INSTITUTIONAL, AND COMMERCIAL BOILERS, STEAM GENERATORS, AND PROCESS ...
Read MoreMar 25, 2008 ... DRAFT 3-18-2008 REGULATION 9 INORGANIC GASEOUS POLLUTANTS RULE 7 NITROGEN OXIDES AND CARBON MONOXIDE FROM INDUSTRIAL, INSTITUTIONAL, AND COMMERCIAL BOILERS, STEAM GENERATORS, AND PROCESS ...
Jul 5, 2016 ... July 5, 2016 Ms. Deborah Jordan Director, Air Division United States Environmental Protection Agency 75 Hawthorne Street San Francisco, CA 94105 Dear Ms. Jordan: The ...
Read MoreJul 5, 2016 ... July 5, 2016 Ms. Deborah Jordan Director, Air Division United States Environmental Protection Agency 75 Hawthorne Street San Francisco, CA 94105 Dear Ms. Jordan: The ...
Jul 13, 2022 ... July 15, 2022 VIA ELECTRONIC MAIL Shawn Lee HSE Manager, Richmond Refinery Chevron Products Company 841 Chevron Way Richmond, CA 94801 RE: Notification of Deficiency in Regulation 12, ...
Read MoreJul 13, 2022 ... July 15, 2022 VIA ELECTRONIC MAIL Shawn Lee HSE Manager, Richmond Refinery Chevron Products Company 841 Chevron Way Richmond, CA 94801 RE: Notification of Deficiency in Regulation 12, ...
Jul 13, 2022 ... July 15, 2022 VIA ELECTRONIC MAIL Michael Marlowe Manager, Environmental Affairs Martinez Refining Company, LLC 3485 Pacheco Boulevard Martinez, CA 94553 RE: Notification of ...
Read MoreJul 13, 2022 ... July 15, 2022 VIA ELECTRONIC MAIL Michael Marlowe Manager, Environmental Affairs Martinez Refining Company, LLC 3485 Pacheco Boulevard Martinez, CA 94553 RE: Notification of ...
Jul 13, 2022 ... July 15, 2022 VIA ELECTRONIC MAIL Anne Partmann Environmental Supervisor – Martinez Refinery Tesoro Refining & Marketing Company LLC 150 Solano Way Martinez, CA 94553 RE: Notification ...
Read MoreJul 13, 2022 ... July 15, 2022 VIA ELECTRONIC MAIL Anne Partmann Environmental Supervisor – Martinez Refinery Tesoro Refining & Marketing Company LLC 150 Solano Way Martinez, CA 94553 RE: Notification ...
Mar 16, 2011 ... DRAFT 3-17-2011 REGULATION 9 INORGANIC GASEOUS POLLUTANTS RULE 7 NITROGEN OXIDES AND CARBON MONOXIDE FROM INDUSTRIAL, INSTITUTIONAL, AND COMMERCIAL BOILERS, STEAM GENERATORS, AND PROCESS ...
Read MoreMar 16, 2011 ... DRAFT 3-17-2011 REGULATION 9 INORGANIC GASEOUS POLLUTANTS RULE 7 NITROGEN OXIDES AND CARBON MONOXIDE FROM INDUSTRIAL, INSTITUTIONAL, AND COMMERCIAL BOILERS, STEAM GENERATORS, AND PROCESS ...
Apr 4, 2011 ... DRAFT 4-4-2011 REGULATION 9 INORGANIC GASEOUS POLLUTANTS RULE 7 NITROGEN OXIDES AND CARBON MONOXIDE FROM INDUSTRIAL, INSTITUTIONAL, AND COMMERCIAL BOILERS, STEAM GENERATORS, AND PROCESS HEATERS ...
Read MoreApr 4, 2011 ... DRAFT 4-4-2011 REGULATION 9 INORGANIC GASEOUS POLLUTANTS RULE 7 NITROGEN OXIDES AND CARBON MONOXIDE FROM INDUSTRIAL, INSTITUTIONAL, AND COMMERCIAL BOILERS, STEAM GENERATORS, AND PROCESS HEATERS ...
Jul 5, 2016 ... Bay Area Air Quality Management District 375 Beale Street, Suite 600 San Francisco, CA 94105 (415) 771-6000 Permit Evaluation and Statement of Basis for MAJOR FACILITY REVIEW ...
Read MoreJul 5, 2016 ... Bay Area Air Quality Management District 375 Beale Street, Suite 600 San Francisco, CA 94105 (415) 771-6000 Permit Evaluation and Statement of Basis for MAJOR FACILITY REVIEW ...
Mar 25, 2008 ... Manual of Procedures, Volume 1, Chapter 5 DRAFT 5. BOILER, STEAM GENERATOR AND PROCESS HEATER TUNING PROCEDURE 5.1 Inspection Procedure for Boilers, Steam Generators and Process Heaters ...
Read MoreMar 25, 2008 ... Manual of Procedures, Volume 1, Chapter 5 DRAFT 5. BOILER, STEAM GENERATOR AND PROCESS HEATER TUNING PROCEDURE 5.1 Inspection Procedure for Boilers, Steam Generators and Process Heaters ...
Jul 14, 2015 ... July 6, 2015 Ms. Deborah Jordan Director, Air Division United States Environmental Protection Agency 75 Hawthorne Street San Francisco, CA 94105 Dear Ms. Jordan: ...
Read MoreJul 14, 2015 ... July 6, 2015 Ms. Deborah Jordan Director, Air Division United States Environmental Protection Agency 75 Hawthorne Street San Francisco, CA 94105 Dear Ms. Jordan: ...
Jul 20, 2023 ... Bay Area Air Quality Management District 939 Ellis Street375 Beale Street San Francisco, CA 9410994105 (415) 771-6000749-5000 Final Proposed Renewal “Revision 65” Minor Revision MAJOR ...
Read MoreJul 20, 2023 ... Bay Area Air Quality Management District 939 Ellis Street375 Beale Street San Francisco, CA 9410994105 (415) 771-6000749-5000 Final Proposed Renewal “Revision 65” Minor Revision MAJOR ...
Sep 26, 1996 ... Source Test Procedure ST-1B AMMONIA INTEGRATED SAMPLING (Adopted January 20, 1982) REF: Regulation 7-303 1. APPLICABILITY 1.1 This method is used to quantify emissions of ammonia. It ...
Read MoreSep 26, 1996 ... Source Test Procedure ST-1B AMMONIA INTEGRATED SAMPLING (Adopted January 20, 1982) REF: Regulation 7-303 1. APPLICABILITY 1.1 This method is used to quantify emissions of ammonia. It ...
Sep 27, 1996 ... Source Test Method ST-11 MERCAPTANS Adopted (January 20, 1982) REF: Regulation 7-303 1. APPLICABILITY 1.1 This method is used to determine emissions of mercaptans. It is applicable to the ...
Read MoreSep 27, 1996 ... Source Test Method ST-11 MERCAPTANS Adopted (January 20, 1982) REF: Regulation 7-303 1. APPLICABILITY 1.1 This method is used to determine emissions of mercaptans. It is applicable to the ...
Mar 16, 2011 ... REQUEST FOR COMMENTS March 17, 2011 TO: INTERESTED PARTIES FROM: EXECUTIVE OFFICER / APCO SUBJECT: REQUEST FOR PUBLIC COMMENTS: PROPOSED AMENDMENTS TO REGULATION 9, RULE 7: NOx AND CO ...
Read MoreMar 16, 2011 ... REQUEST FOR COMMENTS March 17, 2011 TO: INTERESTED PARTIES FROM: EXECUTIVE OFFICER / APCO SUBJECT: REQUEST FOR PUBLIC COMMENTS: PROPOSED AMENDMENTS TO REGULATION 9, RULE 7: NOx AND CO ...
Apr 4, 2011 ... MEMO TO: Dan Belik, Rule Development Manager, BAAQMD FROM: Doug Svensson and Tony Daysog, ADE DATE: March 17, 2011 RE: Proposed Amendments to Regulation 9, Rule 7: Socioeconomic Impacts ...
Read MoreApr 4, 2011 ... MEMO TO: Dan Belik, Rule Development Manager, BAAQMD FROM: Doug Svensson and Tony Daysog, ADE DATE: March 17, 2011 RE: Proposed Amendments to Regulation 9, Rule 7: Socioeconomic Impacts ...
Última actualización: 08/11/2016