|
Advisory
|
Valero Refinery in Benicia notified the Air District of continued refinery equipment shutdowns beginning 2/5. Odors and/or flaring may occur. Air District inspectors will be closely monitoring. Report air quality complaints: 800-334-ODOR or online.
|
|
245 results for 'reg pnu'
Search: 'reg pnu'
245 Search:
Jun 17, 2015 ... REGULATION 3 FEES INDEX 3-100 GENERAL 3-101 Description 3-102 Deleted July 12, 1989 3-103 Exemption, Abatement Devices 3-104 Deleted August 2, 1995 3-105 Exemption, Excavation of Contaminated ...
Read MoreJun 17, 2015 ... REGULATION 3 FEES INDEX 3-100 GENERAL 3-101 Description 3-102 Deleted July 12, 1989 3-103 Exemption, Abatement Devices 3-104 Deleted August 2, 1995 3-105 Exemption, Excavation of Contaminated ...
abr. 30, 2015 ... Proposed Rule Amendments Tracy Lee Air Quality Specialist ...
Read Moreabr. 30, 2015 ... Proposed Rule Amendments Tracy Lee Air Quality Specialist ...
nov. 13, 2015 ... Draft 11-12-2015 REGULATION 6 PARTICULATE MATTER RULE 5 PARTICULATE EMISSIONS FROM REFINERY FLUIDIZED CATALYTIC CRACKING UNITS INDEX 6-5-100 GENERAL 6-5-101 Description 6-5-110 EXEMPTIONS ...
Read Morenov. 13, 2015 ... Draft 11-12-2015 REGULATION 6 PARTICULATE MATTER RULE 5 PARTICULATE EMISSIONS FROM REFINERY FLUIDIZED CATALYTIC CRACKING UNITS INDEX 6-5-100 GENERAL 6-5-101 Description 6-5-110 EXEMPTIONS ...
oct. 21, 2009 ... REGULATION 8, RULE 45 MONTHLY SOLVENT LOG COMPANY NAME ______________________________________Site #________ ADDRESS _________________________________________________________ ...
Read Moreoct. 21, 2009 ... REGULATION 8, RULE 45 MONTHLY SOLVENT LOG COMPANY NAME ______________________________________Site #________ ADDRESS _________________________________________________________ ...
ene. 13, 2016 ... DRAFT January 2016 REGULATION 2 PERMITS RULE 5 NEW SOURCE REVIEW OF TOXIC AIR CONTAMINANTS INDEX 2-5-100 GENERAL 2-5-101 Description 2-5-110 Exemption, Low Emission Levels 2-5-111 Limited ...
Read Moreene. 13, 2016 ... DRAFT January 2016 REGULATION 2 PERMITS RULE 5 NEW SOURCE REVIEW OF TOXIC AIR CONTAMINANTS INDEX 2-5-100 GENERAL 2-5-101 Description 2-5-110 Exemption, Low Emission Levels 2-5-111 Limited ...
oct. 1, 1996 ... Source Test Procedure ST-31 PERCHLOROETHYLENE REF: Regulation 8-27-302 1. APPLICABILITY 1.1 This procedure is used to quantify emissions of perchloroethylene. It is applicable to the determination ...
Read Moreoct. 1, 1996 ... Source Test Procedure ST-31 PERCHLOROETHYLENE REF: Regulation 8-27-302 1. APPLICABILITY 1.1 This procedure is used to quantify emissions of perchloroethylene. It is applicable to the determination ...
oct. 28, 2015 ... October 28, 2015 Socioeconomic Impact Analysis of Proposed Regulation 9, Rule 14: Petroleum Coke Calcining Operations Prepared for: Bay Area Air Quality Management District ...
Read Moreoct. 28, 2015 ... October 28, 2015 Socioeconomic Impact Analysis of Proposed Regulation 9, Rule 14: Petroleum Coke Calcining Operations Prepared for: Bay Area Air Quality Management District ...
nov. 13, 2015 ... REGULATION 9 INORGANIC GASEOUS POLLUTANTS RULE 14 PETROLEUM COKE CALCINING OPERATIONS INDEX 9-14-100 GENERAL 9-14-101 Description 9-14-200 DEFINITIONS 9-14-201 Petroleum Coke Calcining Kiln ...
Read Morenov. 13, 2015 ... REGULATION 9 INORGANIC GASEOUS POLLUTANTS RULE 14 PETROLEUM COKE CALCINING OPERATIONS INDEX 9-14-100 GENERAL 9-14-101 Description 9-14-200 DEFINITIONS 9-14-201 Petroleum Coke Calcining Kiln ...
oct. 23, 2015 ... DRAFT 10-23-15 REGULATION 8 ORGANIC COMPOUNDS RULE 18 EQUIPMENT LEAKS INDEX 8-18-100 GENERAL 8-18-101 Description 8-18-110 Exemption, Controlled Seal Systems and Pressure Relief Devices ...
Read Moreoct. 23, 2015 ... DRAFT 10-23-15 REGULATION 8 ORGANIC COMPOUNDS RULE 18 EQUIPMENT LEAKS INDEX 8-18-100 GENERAL 8-18-101 Description 8-18-110 Exemption, Controlled Seal Systems and Pressure Relief Devices ...
oct. 23, 2015 ... Bay Area Air Quality Management District 939 Ellis Street San Francisco, CA 94109 Staff Report Proposed Regulation 9, Rule 14: PETROLEUM COKE CALCINING OPERATIONS October 2015 ...
Read Moreoct. 23, 2015 ... Bay Area Air Quality Management District 939 Ellis Street San Francisco, CA 94109 Staff Report Proposed Regulation 9, Rule 14: PETROLEUM COKE CALCINING OPERATIONS October 2015 ...
nov. 13, 2015 ... REGULATION 11 HAZARDOUS POLLUTANTS RULE 10 HEXAVALENT CHROMIUM FROM ALL COOLING TOWERS AND TOTAL HYDROCARBON EMISSIONS FROM PETROLEUM REFINERY COOLING TOWERS 11-10-100 GENERAL 11-10-101 ...
Read Morenov. 13, 2015 ... REGULATION 11 HAZARDOUS POLLUTANTS RULE 10 HEXAVALENT CHROMIUM FROM ALL COOLING TOWERS AND TOTAL HYDROCARBON EMISSIONS FROM PETROLEUM REFINERY COOLING TOWERS 11-10-100 GENERAL 11-10-101 ...
mar. 9, 2015 ... AVISO DE TALLERES PÚBLICOS 26 de febrero de 2015 PARA: LAS PARTES INTERESADAS DEL: FUNCIONARIO DE CONTROL DE CONTAMINACIÓN DEL AIRE TEMA: PROPUESTA DE ...
Read Moremar. 9, 2015 ... AVISO DE TALLERES PÚBLICOS 26 de febrero de 2015 PARA: LAS PARTES INTERESADAS DEL: FUNCIONARIO DE CONTROL DE CONTAMINACIÓN DEL AIRE TEMA: PROPUESTA DE ...
ene. 13, 2016 ... WORKSHOP REPORT PROPOSED AMENDMENTS TO: AIR DISTRICT REGULATION 2, RULE 5: NEW SOURCE REVIEW OF TOXIC AIR CONTAMINANTS Prepared by the staff of the Bay Area Air Quality ...
Read Moreene. 13, 2016 ... WORKSHOP REPORT PROPOSED AMENDMENTS TO: AIR DISTRICT REGULATION 2, RULE 5: NEW SOURCE REVIEW OF TOXIC AIR CONTAMINANTS Prepared by the staff of the Bay Area Air Quality ...
ago. 17, 2015 ... Regulation 6: Particulate Matter and Visible Emissions, Rule 3: Wood Burning Devices Proposed Amendments August 17, 2015 Prepared by: Tracy Lee, Air Quality Specialist ...
Read Moreago. 17, 2015 ... Regulation 6: Particulate Matter and Visible Emissions, Rule 3: Wood Burning Devices Proposed Amendments August 17, 2015 Prepared by: Tracy Lee, Air Quality Specialist ...
Última actualización: 08/11/2016