Búsqueda

  • Board Agenda
    Board Agenda

    jul. 26, 2012 ... SPECIAL MEETING OF THE BOARD OF DIRECTORS JULY 30, 2012 A Special Meeting of the Bay Area Air Quality Management District Board of Directors will be held th at 1:30 p.m.

    Read More
    (3 Mb PDF, 104 pgs)

    jul. 26, 2012 ... SPECIAL MEETING OF THE BOARD OF DIRECTORS JULY 30, 2012 A Special Meeting of the Bay Area Air Quality Management District Board of Directors will be held th at 1:30 p.m.

  • 22630 Permit Evaluation
    22630 Permit Evaluation

    Jan 27, 2011 ... ENGINEERING EVALUATION Coca-Cola Bottling Company of California Plant: 20430 Application: 22630 14655 Wicks Blvd San Leandro, CA 94577 BACKGROUND Coca-Cola Bottling Company of California ...

    Read More
    (127 Kb PDF, 4 pgs)

    Jan 27, 2011 ... ENGINEERING EVALUATION Coca-Cola Bottling Company of California Plant: 20430 Application: 22630 14655 Wicks Blvd San Leandro, CA 94577 BACKGROUND Coca-Cola Bottling Company of California ...

  • Webcast Archive Transcript
    Webcast Archive Transcript

    oct. 26, 2022 ... 18:08:25 hey! both of us 18:08:31 How are you doing this, Margaret? i'm fine thank you Hello! 18:08:36 Everyone, 18:08:48 What is it talking? Okay, I'll i'll put it in a chat, Randolph 18:09:04 ...

    Read More
    (158 Kb PDF, 31 pgs)

    oct. 26, 2022 ... 18:08:25 hey! both of us 18:08:31 How are you doing this, Margaret? i'm fine thank you Hello! 18:08:36 Everyone, 18:08:48 What is it talking? Okay, I'll i'll put it in a chat, Randolph 18:09:04 ...

  • AMP public comments 2023
    AMP public comments 2023

    Jul 18, 2023 ... BCAMP Benicia Community Air Monitoring Program April 11, 2023 Bay Area Air Quality Management District Monitoring, Meteorology and ...

    Read More
    (2 Mb PDF, 180 pgs)

    Jul 18, 2023 ... BCAMP Benicia Community Air Monitoring Program April 11, 2023 Bay Area Air Quality Management District Monitoring, Meteorology and ...

  • 31977 Permit Evaluation
    31977 Permit Evaluation

    May 8, 2023 ... Engineering Evaluation Equator Coffees, LLC 115 Jordan Street San Rafael, CA 94901 Plant No. 15081 Application No. 31977 BACKGROUND Equator Coffees, LLC has applied for an Authority to ...

    Read More
    (262 Kb PDF, 12 pgs)

    May 8, 2023 ... Engineering Evaluation Equator Coffees, LLC 115 Jordan Street San Rafael, CA 94901 Plant No. 15081 Application No. 31977 BACKGROUND Equator Coffees, LLC has applied for an Authority to ...

  • 25268 Permit Evaluation
    25268 Permit Evaluation

    Jul 23, 2013 ... DRAFT ENGINEERING EVALUATION Raintree Partners LLC. PLANT 21841 APPLICATION 25268 BACKGROUND Summit Electric, Inc., a consultant, is applying for an Authority to Consult for ...

    Read More
    (338 Kb PDF, 10 pgs)

    Jul 23, 2013 ... DRAFT ENGINEERING EVALUATION Raintree Partners LLC. PLANT 21841 APPLICATION 25268 BACKGROUND Summit Electric, Inc., a consultant, is applying for an Authority to Consult for ...

  • 28371 Permit Evaluation
    28371 Permit Evaluation

    feb. 14, 2017 ... Application #28371 Page 1 of 6 Engineering Evaluation St. Helena Unified School District Application No. 28371 Plant No. 23763 1433 Grayson Avenue, St. Helena, CA 84575 BACKGROUND ...

    Read More
    (441 Kb PDF, 6 pgs)

    feb. 14, 2017 ... Application #28371 Page 1 of 6 Engineering Evaluation St. Helena Unified School District Application No. 28371 Plant No. 23763 1433 Grayson Avenue, St. Helena, CA 84575 BACKGROUND ...

  • 32022 Permit Evaluation
    32022 Permit Evaluation

    Apr 24, 2024 ... Engineering Evaluation South San Francisco-San Bruno Water Quality Plant Application No. 32022 Plant No. 5876 BACKGROUND South San Francisco-San Bruno Water Quality Plant (WQP) has applied to ...

    Read More
    (188 Kb PDF, 12 pgs)

    Apr 24, 2024 ... Engineering Evaluation South San Francisco-San Bruno Water Quality Plant Application No. 32022 Plant No. 5876 BACKGROUND South San Francisco-San Bruno Water Quality Plant (WQP) has applied to ...

  • Engineering Evaluation App 8514
    Engineering Evaluation App 8514

    ago. 26, 2005 ... ENGINEERING EVALUATION West Contra Costa Sanitary Landfill; PLANT # 1840 APPLICATION # 8514 BACKGROUND The West Contra Costa Sanitary Landfill (WCCSL) includes an active Municipal Solid ...

    Read More
    (317 Kb PDF, 24 pgs)

    ago. 26, 2005 ... ENGINEERING EVALUATION West Contra Costa Sanitary Landfill; PLANT # 1840 APPLICATION # 8514 BACKGROUND The West Contra Costa Sanitary Landfill (WCCSL) includes an active Municipal Solid ...

  • 28913 Permit Evaluation
    28913 Permit Evaluation

    ene. 11, 2018 ... ENGINEERING EVALUATION CAFE SANTANA ROASTING COMPANY PLANT NO. 23973 APPLICATION NO: 28913 BACKGROUND Cafe Santana Roasting Company of Oakland, CA is applying for an Authority to ...

    Read More
    (187 Kb PDF, 6 pgs)

    ene. 11, 2018 ... ENGINEERING EVALUATION CAFE SANTANA ROASTING COMPANY PLANT NO. 23973 APPLICATION NO: 28913 BACKGROUND Cafe Santana Roasting Company of Oakland, CA is applying for an Authority to ...

  • Permit Evaluation
    Permit Evaluation

    jul. 3, 2014 ... DRAFT ENGINEERING EVALUATION 32 Shady Lane Application No. 26281 Plant No. 22443 BACKGROUND 32 Shady Lane has applied for an Authority to Construct (AC) and/or Permit to Operate for the ...

    Read More
    (668 Kb PDF, 8 pgs)

    jul. 3, 2014 ... DRAFT ENGINEERING EVALUATION 32 Shady Lane Application No. 26281 Plant No. 22443 BACKGROUND 32 Shady Lane has applied for an Authority to Construct (AC) and/or Permit to Operate for the ...

  • Permit Evaluation
    Permit Evaluation

    Jul 8, 2014 ... DRAFT ENGINEERING EVALUATION Verizon Wireless (Telegraph & Broadway) Application No. 26215 Plant No. 22412 BACKGROUND Verizon Wireless has applied for an Authority to Construct (AC) ...

    Read More
    (669 Kb PDF, 8 pgs)

    Jul 8, 2014 ... DRAFT ENGINEERING EVALUATION Verizon Wireless (Telegraph & Broadway) Application No. 26215 Plant No. 22412 BACKGROUND Verizon Wireless has applied for an Authority to Construct (AC) ...

  • 27278 Permit Evaluation
    27278 Permit Evaluation

    Jul 31, 2015 ... DRAFT ENGINEERING EVALUATION Linden Residence Application No. 27278 Plant No. 23128 BACKGROUND Linden Residence has applied for an Authority to Construct (AC) and/or Permit to Operate for ...

    Read More
    (335 Kb PDF, 8 pgs)

    Jul 31, 2015 ... DRAFT ENGINEERING EVALUATION Linden Residence Application No. 27278 Plant No. 23128 BACKGROUND Linden Residence has applied for an Authority to Construct (AC) and/or Permit to Operate for ...

  • Semi-Annual Monitoring Report 2021 B
    Semi-Annual Monitoring Report 2021 B

    May 27, 2022 ... OWENS CORNING INSULATING SYSTEMS, LLC Santa Clara Facility 960 Central Expressway Santa Clara, California 95050 May 27, 2022 Director of Compliance and Enforcement Bay Area Air ...

    Read More
    (1 Mb PDF, 59 pgs)

    May 27, 2022 ... OWENS CORNING INSULATING SYSTEMS, LLC Santa Clara Facility 960 Central Expressway Santa Clara, California 95050 May 27, 2022 Director of Compliance and Enforcement Bay Area Air ...

  • Semi-Annual Monitoring Report 2021 A
    Semi-Annual Monitoring Report 2021 A

    oct. 22, 2021 ... Mailing Address: Pacific Gas & Electric Company Pacific Gas and Gateway Generating Station ® 3225 Wilbur Ave. Electric Company Antioch, CA 94509 _________________________________________ ...

    Read More
    (3 Mb PDF, 64 pgs)

    oct. 22, 2021 ... Mailing Address: Pacific Gas & Electric Company Pacific Gas and Gateway Generating Station ® 3225 Wilbur Ave. Electric Company Antioch, CA 94509 _________________________________________ ...

  • 05/07/2020 Cancellation TV Permit Evaluation
    05/07/2020 Cancellation TV Permit Evaluation

    May 8, 2020 ... Title V Status Evaluation Report Palo Alto Water Quality Control Plant, Site #A0617 Palo Alto Landfill, Site #A2721 April 28, 2020 The potential to emit calculation in this evaluation report ...

    Read More
    (503 Kb PDF, 23 pgs)

    May 8, 2020 ... Title V Status Evaluation Report Palo Alto Water Quality Control Plant, Site #A0617 Palo Alto Landfill, Site #A2721 April 28, 2020 The potential to emit calculation in this evaluation report ...

  • Appendix A
    Appendix A

    feb. 16, 2012 ... APPENDIX A EMISSIONS INVENTORY The development of an emissions inventory requires information on the emission rates for an activity (i.e., the expected emissions for a given unit or volume of ...

    Read More
    (57 Kb PDF, 9 pgs)

    feb. 16, 2012 ... APPENDIX A EMISSIONS INVENTORY The development of an emissions inventory requires information on the emission rates for an activity (i.e., the expected emissions for a given unit or volume of ...

  • 31805 Permit Evaluation
    31805 Permit Evaluation

    abr. 12, 2023 ... DRAFT ENGINEERING EVALUATION Plant No. 9029 Kie-Con Inc. 3551 Wilbur Avenue, Antioch, CA, 94509 Application No. 31805 Background Kie-Con is applying for an Authority to Construct (A/C) ...

    Read More
    (423 Kb PDF, 10 pgs)

    abr. 12, 2023 ... DRAFT ENGINEERING EVALUATION Plant No. 9029 Kie-Con Inc. 3551 Wilbur Avenue, Antioch, CA, 94509 Application No. 31805 Background Kie-Con is applying for an Authority to Construct (A/C) ...

  • Semi-Annual Monitoring Report 2019 A
    Semi-Annual Monitoring Report 2019 A

    Sep 25, 2019 ... SIGNED BY BAAQMD MAILROOM SEP 2 4 2019 Silicon Valley Power SILICON City of Santa Clara Ur\l•'-'-·''J 375 BEALE ST, S1E 600, SF CA 94105 ,~.J'...,j,, VALLEY 1500 Warburton Ave. Santa Clara, ...

    Read More
    (5 Mb PDF, 11 pgs)

    Sep 25, 2019 ... SIGNED BY BAAQMD MAILROOM SEP 2 4 2019 Silicon Valley Power SILICON City of Santa Clara Ur\l•'-'-·''J 375 BEALE ST, S1E 600, SF CA 94105 ,~.J'...,j,, VALLEY 1500 Warburton Ave. Santa Clara, ...

Spare the Air Status

Última actualización: 08/11/2016