125 results for '250003 REF'
Search: '250003 REF'
125 Search:
Jun 29, 2011 ... June 28, 2011 Ms. Deborah Jordan Director, Air Division United States Environmental Protection Agency 75 Hawthorne Street San Francisco, CA 94105 Dear Ms. Jordan: ...
Read MoreJun 29, 2011 ... June 28, 2011 Ms. Deborah Jordan Director, Air Division United States Environmental Protection Agency 75 Hawthorne Street San Francisco, CA 94105 Dear Ms. Jordan: ...
May 18, 2007 ... Bay Area Air Quality Management District 939 Ellis Street San Francisco, CA 94109 (415) 771-6000 March 19 2007 Permit Evaluation and Statement of Basis for MAJOR FACILITY REVIEW PERMIT ...
Read MoreMay 18, 2007 ... Bay Area Air Quality Management District 939 Ellis Street San Francisco, CA 94109 (415) 771-6000 March 19 2007 Permit Evaluation and Statement of Basis for MAJOR FACILITY REVIEW PERMIT ...
Sep 17, 2013 ... From: Floyd Smith
Sep 17, 2013 ... From: Floyd Smith
Sep 27, 1996 ... Source Test Method ST-8 DIMETHYLSULFIDE (Adopted January 20, 1982) REF: Regulation 7-303 1. APPLICABILITY 1.1 This method is used to determine emissions of dimethylsulfide (DMS). It is applicable ...
Read MoreSep 27, 1996 ... Source Test Method ST-8 DIMETHYLSULFIDE (Adopted January 20, 1982) REF: Regulation 7-303 1. APPLICABILITY 1.1 This method is used to determine emissions of dimethylsulfide (DMS). It is applicable ...
Sep 27, 1996 ... Source Test Method ST-11 MERCAPTANS Adopted (January 20, 1982) REF: Regulation 7-303 1. APPLICABILITY 1.1 This method is used to determine emissions of mercaptans. It is applicable to the ...
Read MoreSep 27, 1996 ... Source Test Method ST-11 MERCAPTANS Adopted (January 20, 1982) REF: Regulation 7-303 1. APPLICABILITY 1.1 This method is used to determine emissions of mercaptans. It is applicable to the ...
Aug 26, 2019 ... PUBLIC NOTICE September 4, 2019 TO: Parents or guardians of children enrolled at the following school(s): Santa Rosa French-American Charter School All residential and business ...
Read MoreAug 26, 2019 ... PUBLIC NOTICE September 4, 2019 TO: Parents or guardians of children enrolled at the following school(s): Santa Rosa French-American Charter School All residential and business ...
Jun 14, 2023 ... PUBLIC NOTICE th June 16 , 2023 TO: All residential and business neighbors located within 1,000 feet of the proposed new or modified source(s) of air pollution listed below. FROM: Bay ...
Read MoreJun 14, 2023 ... PUBLIC NOTICE th June 16 , 2023 TO: All residential and business neighbors located within 1,000 feet of the proposed new or modified source(s) of air pollution listed below. FROM: Bay ...
Mar 7, 2023 ... PUBLIC NOTICE th March 10 , 2023 TO: All residential and business neighbors located within 1,000 feet of the proposed new or modified source(s) of air pollution listed below. FROM: Bay ...
Read MoreMar 7, 2023 ... PUBLIC NOTICE th March 10 , 2023 TO: All residential and business neighbors located within 1,000 feet of the proposed new or modified source(s) of air pollution listed below. FROM: Bay ...
Apr 11, 2023 ... PUBLIC NOTICE April 13, 2023 TO: All residential and business neighbors located within 1,000 feet of the proposed new or modified source(s) of air pollution listed below. FROM: Bay ...
Read MoreApr 11, 2023 ... PUBLIC NOTICE April 13, 2023 TO: All residential and business neighbors located within 1,000 feet of the proposed new or modified source(s) of air pollution listed below. FROM: Bay ...
May 13, 2009 ... METHOD 2 REF: Regs: 11-3-301 to 11-3-303 DETERMINATION OF BERYLLIUM IN EFFLUENT AND ATMOSPHERIC PARTICULATE MATTER 1) PRINCIPLE Samples are collected by passing a ...
Read MoreMay 13, 2009 ... METHOD 2 REF: Regs: 11-3-301 to 11-3-303 DETERMINATION OF BERYLLIUM IN EFFLUENT AND ATMOSPHERIC PARTICULATE MATTER 1) PRINCIPLE Samples are collected by passing a ...
Oct 7, 1996 ... Source Test Method ST-12 COLLECTION OF ODOROUS SAMPLES (Adopted January 20, 1982) REF: Regulation 7-401 1. APPLICABILITY 1.1 This method is used for the collection of odorous samples to be ...
Read MoreOct 7, 1996 ... Source Test Method ST-12 COLLECTION OF ODOROUS SAMPLES (Adopted January 20, 1982) REF: Regulation 7-401 1. APPLICABILITY 1.1 This method is used for the collection of odorous samples to be ...
Mar 19, 2014 ... EXAMPLE COST-EFFECTIVENESS CALCULATIONS FOR NO CONTROLS x The following pages provide example calculations for determining the cost-effectiveness of NO x control options for steam generating ...
Read MoreMar 19, 2014 ... EXAMPLE COST-EFFECTIVENESS CALCULATIONS FOR NO CONTROLS x The following pages provide example calculations for determining the cost-effectiveness of NO x control options for steam generating ...
Aug 15, 2019 ... Benicia Refinery • Valero Refining Company - California 3400 East Second Street- Benicia, California 94510-1097 • Telephone (707) 745-7011 • Facsimile (707) 745-7339 Certified Mail# 7011 0470 0003 ...
Read MoreAug 15, 2019 ... Benicia Refinery • Valero Refining Company - California 3400 East Second Street- Benicia, California 94510-1097 • Telephone (707) 745-7011 • Facsimile (707) 745-7339 Certified Mail# 7011 0470 0003 ...
May 15, 2009 ... Method 23 (Amended 4/15/92) METHOD 23 REF: Reg 8-50 DETERMINATION OF VOLATILE EMISSIONS FROM POLYESTER RESINS 1) PRINCIPLE 1.1 A pour pan method is used, where a weighed ...
Read MoreMay 15, 2009 ... Method 23 (Amended 4/15/92) METHOD 23 REF: Reg 8-50 DETERMINATION OF VOLATILE EMISSIONS FROM POLYESTER RESINS 1) PRINCIPLE 1.1 A pour pan method is used, where a weighed ...
Apr 4, 2016 ... Plant 23196 1 Application 27391 DRAFT ENGINEERING EVALUATION REPORT FORMER RICHARD’S AUTO SERVICE PLANT NUMBER 23196 APPLICATION NUMBER 27391 1495 Hays Street San Leandro, CA 94577 ...
Read MoreApr 4, 2016 ... Plant 23196 1 Application 27391 DRAFT ENGINEERING EVALUATION REPORT FORMER RICHARD’S AUTO SERVICE PLANT NUMBER 23196 APPLICATION NUMBER 27391 1495 Hays Street San Leandro, CA 94577 ...
Mar 2, 2009 ... Bay Area Air Quality Management District 939 Ellis Street San Francisco, CA 94109 (415) 771-6000 Permit Evaluation and Statement of Basis for RENEWAL of MAJOR FACILITY REVIEW ...
Read MoreMar 2, 2009 ... Bay Area Air Quality Management District 939 Ellis Street San Francisco, CA 94109 (415) 771-6000 Permit Evaluation and Statement of Basis for RENEWAL of MAJOR FACILITY REVIEW ...
May 10, 2019 ... Air Quality and Health Outcomes: What we Know, What to Do Rohan Radhakrishna MD, MPH, MS Chair – Family and Adult Medicine Deputy Health Officer, Contra Costa ...
Read MoreMay 10, 2019 ... Air Quality and Health Outcomes: What we Know, What to Do Rohan Radhakrishna MD, MPH, MS Chair – Family and Adult Medicine Deputy Health Officer, Contra Costa ...
Oct 1, 1996 ... Source Test Procedure ST-32 ETHANOL, INTEGRATED SAMPLING (Adopted December 21, 1988) REF: Regulation 8, Rule 42 1. APPLICABILITY 1.1 This procedure is used to quantify emissions of ethanol. It ...
Read MoreOct 1, 1996 ... Source Test Procedure ST-32 ETHANOL, INTEGRATED SAMPLING (Adopted December 21, 1988) REF: Regulation 8, Rule 42 1. APPLICABILITY 1.1 This procedure is used to quantify emissions of ethanol. It ...
Feb 26, 2024 ... BAAQMD received 02/27/24 FLARE CAUSAL ANALYSIS REPORT - PUBLIC 1. Date on which the report was drafted: February 21, 2024 2. The refinery name and site number. Martinez Refinery, Plant # B2758 3.
Read MoreFeb 26, 2024 ... BAAQMD received 02/27/24 FLARE CAUSAL ANALYSIS REPORT - PUBLIC 1. Date on which the report was drafted: February 21, 2024 2. The refinery name and site number. Martinez Refinery, Plant # B2758 3.