搜尋

  • 96 3 3
    96 3 3

    三月 19, 2014 ... Source Category Revision: 1 IC Engine – Spark Ignition, Natural Gas Fired Source: Document Lean Burn Engine 96.3.3 #: Class: >= 50 HP Date: 5/7/03 Determination POLLUTANT BACT ...

    Read More
    (190 Kb PDF, 1 pg)

    三月 19, 2014 ... Source Category Revision: 1 IC Engine – Spark Ignition, Natural Gas Fired Source: Document Lean Burn Engine 96.3.3 #: Class: >= 50 HP Date: 5/7/03 Determination POLLUTANT BACT ...

  • 89 1 2
    89 1 2

    三月 19, 2014 ... BAY AREA AIR QUALITY MANAGEMENT DISTRICT Best Available Control Technology (BACT) Guideline Source Category Revision: 1 Source: Gas Turbine Document #: 89.1.2 Class: Simple Cycle (> = 2 .0 MW ...

    Read More
    (95 Kb PDF, 1 pg)

    三月 19, 2014 ... BAY AREA AIR QUALITY MANAGEMENT DISTRICT Best Available Control Technology (BACT) Guideline Source Category Revision: 1 Source: Gas Turbine Document #: 89.1.2 Class: Simple Cycle (> = 2 .0 MW ...

  • 151 1
    151 1

    四月 16, 2014 ... BAY AREA AIR QUALITY MANAGEMENT DISTRICT Best Available Control Technology (BACT) Guideline Source Category Revision: 1 Source: Smokehouse Document 151.1 #: Class: All Date: 09/13/91 ...

    Read More
    (88 Kb PDF, 1 pg)

    四月 16, 2014 ... BAY AREA AIR QUALITY MANAGEMENT DISTRICT Best Available Control Technology (BACT) Guideline Source Category Revision: 1 Source: Smokehouse Document 151.1 #: Class: All Date: 09/13/91 ...

  • 89 1 5
    89 1 5

    三月 19, 2014 ... BAY AREA AIR QUALITY MANAGEMENT DISTRICT Best Available Control Technology (BACT) Guideline Source Category Revision: 1 Source: Gas Turbine Document #: 89.1.5 Class: Combined Cycle (> = 2.0 MW ...

    Read More
    (95 Kb PDF, 1 pg)

    三月 19, 2014 ... BAY AREA AIR QUALITY MANAGEMENT DISTRICT Best Available Control Technology (BACT) Guideline Source Category Revision: 1 Source: Gas Turbine Document #: 89.1.5 Class: Combined Cycle (> = 2.0 MW ...

  • 89 3 1
    89 3 1

    四月 15, 2014 ... BAY AREA AIR QUALITY MANAGEMENT DISTRICT Best Available Control Technology (BACT) Guideline Source Category Revision: 1 Source: Gas Turbine - Landfill Gas-Fired Document 89.3.1 #: Class: All ...

    Read More
    (94 Kb PDF, 1 pg)

    四月 15, 2014 ... BAY AREA AIR QUALITY MANAGEMENT DISTRICT Best Available Control Technology (BACT) Guideline Source Category Revision: 1 Source: Gas Turbine - Landfill Gas-Fired Document 89.3.1 #: Class: All ...

  • 89 3 1
    89 3 1

    三月 19, 2014 ... BAY AREA AIR QUALITY MANAGEMENT DISTRICT Best Available Control Technology (BACT) Guideline Source Category Revision: 1 Source: Gas Turbine - Landfill Gas-Fired Document 89.3.1 #: Class: All ...

    Read More
    (95 Kb PDF, 1 pg)

    三月 19, 2014 ... BAY AREA AIR QUALITY MANAGEMENT DISTRICT Best Available Control Technology (BACT) Guideline Source Category Revision: 1 Source: Gas Turbine - Landfill Gas-Fired Document 89.3.1 #: Class: All ...

  • Committee Presentations
    Committee Presentations

    三月 23, 2017 ... AGENDA: 4 Bay Area Air Quality Management District Mobile Source Committee Projects with proposed awards over $100,000 March 23, 2017 Damian Breen Deputy Air Pollution Control ...

    Read More
    (1 Mb PDF, 25 pgs)

    三月 23, 2017 ... AGENDA: 4 Bay Area Air Quality Management District Mobile Source Committee Projects with proposed awards over $100,000 March 23, 2017 Damian Breen Deputy Air Pollution Control ...

  • 109 2
    109 2

    三月 20, 2014 ... BAY AREA AIR QUALITY MANAGEMENT DISTRICT Best Available Control Technology (BACT) Guideline Source Category Revision: 1 Liquid Transfer & Handling - Tank Truck & Rail Car Source: Document Bulk ...

    Read More
    (93 Kb PDF, 1 pg)

    三月 20, 2014 ... BAY AREA AIR QUALITY MANAGEMENT DISTRICT Best Available Control Technology (BACT) Guideline Source Category Revision: 1 Liquid Transfer & Handling - Tank Truck & Rail Car Source: Document Bulk ...

  • 17 5 1
    17 5 1

    Mar 12, 2014 ... BAY AREA AIR QUALITY MANAGEMENT DISTRICT Best Available Control Technology (BACT) Guideline Source Category Revision: 2 Source: Boiler or Water Heater - Landfill or Digester Gas Document 17.5.1 ...

    Read More
    (95 Kb PDF, 1 pg)

    Mar 12, 2014 ... BAY AREA AIR QUALITY MANAGEMENT DISTRICT Best Available Control Technology (BACT) Guideline Source Category Revision: 2 Source: Boiler or Water Heater - Landfill or Digester Gas Document 17.5.1 ...

  • 29954 Permit Evaluation
    29954 Permit Evaluation

    Dec 4, 2019 ... DRAFT ENGINEERING EVALUATION 130 Britton, Plant No. 23862 Application No. 29954 130 Britton Ave, Atherton, CA A. BACKGROUND An application for a Permit to Operate for the following ...

    Read More
    (249 Kb PDF, 10 pgs)

    Dec 4, 2019 ... DRAFT ENGINEERING EVALUATION 130 Britton, Plant No. 23862 Application No. 29954 130 Britton Ave, Atherton, CA A. BACKGROUND An application for a Permit to Operate for the following ...

  • 80 1
    80 1

    四月 15, 2014 ... BAY AREA AIR QUALITY MANAGEMENT DISTRICT Best Available Control Technology (BACT) Guideline Source Category Revision: 1 Flare - Digester Gas or Landfill Gas from Non- Source: Hazardous Waste ...

    Read More
    (94 Kb PDF, 1 pg)

    四月 15, 2014 ... BAY AREA AIR QUALITY MANAGEMENT DISTRICT Best Available Control Technology (BACT) Guideline Source Category Revision: 1 Flare - Digester Gas or Landfill Gas from Non- Source: Hazardous Waste ...

  • 156 1
    156 1

    四月 16, 2014 ... BAY AREA AIR QUALITY MANAGEMENT DISTRICT Best Available Control Technology (BACT) Guideline Source Category Revision: 1 Solid Material Handling (Conveying, Size Reduction, Source: ...

    Read More
    (93 Kb PDF, 1 pg)

    四月 16, 2014 ... BAY AREA AIR QUALITY MANAGEMENT DISTRICT Best Available Control Technology (BACT) Guideline Source Category Revision: 1 Solid Material Handling (Conveying, Size Reduction, Source: ...

  • 160 1
    160 1

    四月 8, 2014 ... BAY AREA AIR QUALITY MANAGEMENT DISTRICT Best Available Control Technology (BACT) Guideline Source Category Revision: 1 Source: Solvent Reclamation Document #: 160.1 Class: All Date: 10/28/91 ...

    Read More
    (94 Kb PDF, 1 pg)

    四月 8, 2014 ... BAY AREA AIR QUALITY MANAGEMENT DISTRICT Best Available Control Technology (BACT) Guideline Source Category Revision: 1 Source: Solvent Reclamation Document #: 160.1 Class: All Date: 10/28/91 ...

  • 53 1
    53 1

    八月 21, 2012 ... BAY AREA AIR QUALITY MANAGEMENT DISTRICT Best Available Control Technology (BACT) Guideline Source Category Revision: 1 Source: Crematory Document #: 53.1 Class: Date: All 9/12/2007 ...

    Read More
    (76 Kb PDF, 1 pg)

    八月 21, 2012 ... BAY AREA AIR QUALITY MANAGEMENT DISTRICT Best Available Control Technology (BACT) Guideline Source Category Revision: 1 Source: Crematory Document #: 53.1 Class: Date: All 9/12/2007 ...

  • 41 1
    41 1

    三月 20, 2014 ... BAY AREA AIR QUALITY MANAGEMENT DISTRICT Best Available Control Technology (BACT) Guideline Source Category Revision: 1 Source: Cement Kiln Document #: 41.1 Class: All Date: 01/17/92 ...

    Read More
    (94 Kb PDF, 1 pg)

    三月 20, 2014 ... BAY AREA AIR QUALITY MANAGEMENT DISTRICT Best Available Control Technology (BACT) Guideline Source Category Revision: 1 Source: Cement Kiln Document #: 41.1 Class: All Date: 01/17/92 ...

  • 146 1
    146 1

    四月 7, 2014 ... BAY AREA AIR QUALITY MANAGEMENT DISTRICT Best Available Control Technology (BACT) Guideline Source Category Revision: 1 Source: Rotogravure Printing - Publication and Packaging Document #: 146.1 ...

    Read More
    (95 Kb PDF, 1 pg)

    四月 7, 2014 ... BAY AREA AIR QUALITY MANAGEMENT DISTRICT Best Available Control Technology (BACT) Guideline Source Category Revision: 1 Source: Rotogravure Printing - Publication and Packaging Document #: 146.1 ...

  • 161 8 1
    161 8 1

    四月 7, 2014 ... BAY AREA AIR QUALITY MANAGEMENT DISTRICT Best Available Control Technology (BACT) Guideline Source Category Revision: 2 Source: Spray Booth - Coating of Wood Products Document #: 161.8.1 Class: ...

    Read More
    (97 Kb PDF, 2 pgs)

    四月 7, 2014 ... BAY AREA AIR QUALITY MANAGEMENT DISTRICT Best Available Control Technology (BACT) Guideline Source Category Revision: 2 Source: Spray Booth - Coating of Wood Products Document #: 161.8.1 Class: ...

  • 84 2 1
    84 2 1

    四月 7, 2014 ... BAY AREA AIR QUALITY MANAGEMENT DISTRICT Best Available Control Technology (BACT) Guideline Source Category Revision: 1 Source: Flow Coater, Dip Tank and Roller Coater Document #: 84.2.1 Class: ...

    Read More
    (97 Kb PDF, 2 pgs)

    四月 7, 2014 ... BAY AREA AIR QUALITY MANAGEMENT DISTRICT Best Available Control Technology (BACT) Guideline Source Category Revision: 1 Source: Flow Coater, Dip Tank and Roller Coater Document #: 84.2.1 Class: ...

  • 129 4 1
    129 4 1

    Apr 16, 2014 ... BAY AREA AIR QUALITY MANAGEMENT DISTRICT Best Available Control Technology (BACT) Guideline Source Category Revision: 1 Source: Polyester Resin Operations - Pultrusion Document #: 129.4.1 ...

    Read More
    (88 Kb PDF, 1 pg)

    Apr 16, 2014 ... BAY AREA AIR QUALITY MANAGEMENT DISTRICT Best Available Control Technology (BACT) Guideline Source Category Revision: 1 Source: Polyester Resin Operations - Pultrusion Document #: 129.4.1 ...

  • 129 2 1
    129 2 1

    四月 16, 2014 ... BAY AREA AIR QUALITY MANAGEMENT DISTRICT Best Available Control Technology (BACT) Guideline Source Category Revision: 2 Source: Polyester Resin Operations - Hand and Spray Layup Document #: ...

    Read More
    (88 Kb PDF, 1 pg)

    四月 16, 2014 ... BAY AREA AIR QUALITY MANAGEMENT DISTRICT Best Available Control Technology (BACT) Guideline Source Category Revision: 2 Source: Polyester Resin Operations - Hand and Spray Layup Document #: ...

Spare the Air Status

上次更新: 2016/11/8