Hanapin

  • Approved Chevron TDLAS SOP
    Approved Chevron TDLAS SOP

    Jun 5, 2025 ... Unisearch LasIR TDLAS Maintenance and Test Procedures; STI-7801 May 30, 2025 Version 4 Page 1 of 26 Unisearch LasIR Tunable Diode Laser System (TDLAS) Maintenance and Test Procedure ...

    Read More
    (832 Kb PDF, 26 pgs)

    Jun 5, 2025 ... Unisearch LasIR TDLAS Maintenance and Test Procedures; STI-7801 May 30, 2025 Version 4 Page 1 of 26 Unisearch LasIR Tunable Diode Laser System (TDLAS) Maintenance and Test Procedure ...

  • Boiler, Steam Generator, and Process Heater Tuning Procedure
    Boiler, Steam Generator, and Process Heater Tuning Procedure

    Aug 7, 2008 ... 5. BOILER, STEAM GENERATOR AND PROCESS HEATER TUNING PROCEDURE 5.1 Inspection Procedure for Boilers, Steam Generators and Process Heaters 5.1.1 Using a thermometer and probe with a ...

    Read More
    (64 Kb PDF, 6 pgs)

    Aug 7, 2008 ... 5. BOILER, STEAM GENERATOR AND PROCESS HEATER TUNING PROCEDURE 5.1 Inspection Procedure for Boilers, Steam Generators and Process Heaters 5.1.1 Using a thermometer and probe with a ...

  • P66 Revised AMP and QAPP
    P66 Revised AMP and QAPP

    Sep 5, 2023 ... Air Monitoring Plan for the Phillips 66 Refinery in Rodeo, California Prepared for Phillips 66 San Francisco Refinery Rodeo, CA Updated: September 5, 2023 Original: July 9, 2021 ...

    Read More
    (5 Mb PDF, 186 pgs)

    Sep 5, 2023 ... Air Monitoring Plan for the Phillips 66 Refinery in Rodeo, California Prepared for Phillips 66 San Francisco Refinery Rodeo, CA Updated: September 5, 2023 Original: July 9, 2021 ...

  • Air Monitoring Van – Quality Assurance Project Plan
    Air Monitoring Van – Quality Assurance Project Plan

    Jan 29, 2025 ... Docusign Envelope ID: 45F078F8-5BB4-471D-AF20-16B187D47AA6 Group A: Project Management and Data Quality Objectives QUALITY ASSURANCE PROJECT PLAN (QAPP) A1. Title Page Local-Scale ...

    Read More
    (13 Mb PDF, 750 pgs)

    Jan 29, 2025 ... Docusign Envelope ID: 45F078F8-5BB4-471D-AF20-16B187D47AA6 Group A: Project Management and Data Quality Objectives QUALITY ASSURANCE PROJECT PLAN (QAPP) A1. Title Page Local-Scale ...

  • Chevron Revised AMP and QAPP
    Chevron Revised AMP and QAPP

    Sep 1, 2023 ... Fenceline Air Monitoring Plan For BAAQMD Rule 12-15 Chevron Richmond Refinery Revision 3 September 5, 2023 ...

    Read More
    (6 Mb PDF, 179 pgs)

    Sep 1, 2023 ... Fenceline Air Monitoring Plan For BAAQMD Rule 12-15 Chevron Richmond Refinery Revision 3 September 5, 2023 ...

  • Agreement
    Agreement

    Apr 17, 2026 ... Docusign Envelope ID: 7B3AC1C1-18F4-415F-A48F-534B59CD80E1 SETTLEMENT AGREEMENT BY AND BETWEEN THE BAY AREA AIR QUALITY MANAGEMENT DISTRICT AND VALERO REFINING COMPANY – CALIFORNIA (Notices of ...

    Read More
    (7 Mb PDF, 201 pgs)

    Apr 17, 2026 ... Docusign Envelope ID: 7B3AC1C1-18F4-415F-A48F-534B59CD80E1 SETTLEMENT AGREEMENT BY AND BETWEEN THE BAY AREA AIR QUALITY MANAGEMENT DISTRICT AND VALERO REFINING COMPANY – CALIFORNIA (Notices of ...

  • Valero AMP and QAPP
    Valero AMP and QAPP

    Sep 5, 2023 ... Air Monitoring Plan for the Valero Refinery in Benicia, California Prepared for Valero Refining Company - CA Benicia Refinery Benicia, CA Updated: September 5, 2023 Original: September ...

    Read More
    (5 Mb PDF, 167 pgs)

    Sep 5, 2023 ... Air Monitoring Plan for the Valero Refinery in Benicia, California Prepared for Valero Refining Company - CA Benicia Refinery Benicia, CA Updated: September 5, 2023 Original: September ...

  • Natural and Working Land Sector
    Natural and Working Land Sector

    Jan 9, 2017 ... 2017 Plan Volume 2 — Natural and Working Lands Sector NW1: Carbon Sequestration in Rangelands Brief Summary: This control measure would increase carbon sequestration in rangelands across the ...

    Read More
    (298 Kb PDF, 15 pgs)

    Jan 9, 2017 ... 2017 Plan Volume 2 — Natural and Working Lands Sector NW1: Carbon Sequestration in Rangelands Brief Summary: This control measure would increase carbon sequestration in rangelands across the ...

  • MRC NOD attachment
    MRC NOD attachment

    Jul 18, 2023 ... Attachment 1 – Basis for Determination That Martinez Refining Company’s Revised Fenceline Air Monitoring Plan and Quality Assurance Project Plan (Submitted February 15, 2023) Do Not Meet District ...

    Read More
    (195 Kb PDF, 5 pgs)

    Jul 18, 2023 ... Attachment 1 – Basis for Determination That Martinez Refining Company’s Revised Fenceline Air Monitoring Plan and Quality Assurance Project Plan (Submitted February 15, 2023) Do Not Meet District ...

  • AB&I Foundry (5-Year Update)
    AB&I Foundry (5-Year Update)

    Jun 1, 2021 ... Emissions Minimization Plan Regulation 12, Miscellaneous Standards of Performance, Rule 13 Foundry and Forging Operations AB&I Foundry District Site #62 7825 San Leandro Street Oakland, ...

    Read More
    (3 Mb PDF, 74 pgs)

    Jun 1, 2021 ... Emissions Minimization Plan Regulation 12, Miscellaneous Standards of Performance, Rule 13 Foundry and Forging Operations AB&I Foundry District Site #62 7825 San Leandro Street Oakland, ...

  • Resolution and Governing Structure pdf
    Resolution and Governing Structure pdf

    Okt 3, 2023 ... DocuSign Envelope ID: F54C0746-53B3-4085-A1E8-842CFAB18F9F BAY AREA AIR QUALITY MANAGEMENT DISTRICT RESOLUTION No. 2023 – 14 A Resolution of the Board of Directors of the Bay Area Air Quality ...

    Read More
    (297 Kb PDF, 5 pgs)

    Okt 3, 2023 ... DocuSign Envelope ID: F54C0746-53B3-4085-A1E8-842CFAB18F9F BAY AREA AIR QUALITY MANAGEMENT DISTRICT RESOLUTION No. 2023 – 14 A Resolution of the Board of Directors of the Bay Area Air Quality ...

  • Supporting Evaluations
    Supporting Evaluations

    Feb 18, 2005 ... ENGINEERING EVALUATION CONOCOPHILLIPS SAN FRANCISCO REFINERY; PLANT 16 APPLICATION 10332 1.0 BACKGROUND ConocoPhillips has applied to increase the permitted throughput at the S-305 Naphtha ...

    Read More
    (23 Kb PDF, 5 pgs)

    Feb 18, 2005 ... ENGINEERING EVALUATION CONOCOPHILLIPS SAN FRANCISCO REFINERY; PLANT 16 APPLICATION 10332 1.0 BACKGROUND ConocoPhillips has applied to increase the permitted throughput at the S-305 Naphtha ...

  • Approved Tesoro Visibility Sensor
    Approved Tesoro Visibility Sensor

    Oct 25, 2024 ... Belfort Model 6400 Visibility Sensor SOP, STI-6991 October 31, 2024 Version 3 Page 1 of 8 Standard Operating Procedures for the Belfort Model 6400 Visibility Sensor October 31, 2024 ...

    Read More
    (348 Kb PDF, 8 pgs)

    Oct 25, 2024 ... Belfort Model 6400 Visibility Sensor SOP, STI-6991 October 31, 2024 Version 3 Page 1 of 8 Standard Operating Procedures for the Belfort Model 6400 Visibility Sensor October 31, 2024 ...

  • Draft HRA Report
    Draft HRA Report

    Jul 15, 2020 ... BAAQMD Draft Facility-Wide Health Risk Assessment Facility # A0621 City of Santa Clara July 15, 2020 Prepared by: Irma Salinas, Principal Engineer Approved by: ...

    Read More
    (3 Mb PDF, 77 pgs)

    Jul 15, 2020 ... BAAQMD Draft Facility-Wide Health Risk Assessment Facility # A0621 City of Santa Clara July 15, 2020 Prepared by: Irma Salinas, Principal Engineer Approved by: ...

  • 2017 Chevron AMP Appendix B
    2017 Chevron AMP Appendix B

    Set 7, 2017 ... Quality Assurance Project Plan for the Chevron Richmond Refinery Fence Line Air Monitoring Program September 7, ...

    Read More
    (247 Kb PDF, 16 pgs)

    Set 7, 2017 ... Quality Assurance Project Plan for the Chevron Richmond Refinery Fence Line Air Monitoring Program September 7, ...

  • Land Use Guidance Flow Diagram
    Land Use Guidance Flow Diagram

    Set 15, 2008 ... DRAFT LOCAL LAND USE GUIDANCE FLOW DIAGRAM New Land Use Project Residential Development Screening Criteria Below Screening • Source-specific setbacks • Multiple source screen Above ...

    Read More
    (49 Kb PDF, 1 pg)

    Set 15, 2008 ... DRAFT LOCAL LAND USE GUIDANCE FLOW DIAGRAM New Land Use Project Residential Development Screening Criteria Below Screening • Source-specific setbacks • Multiple source screen Above ...

  • Land Use Guidance Flow Diagram
    Land Use Guidance Flow Diagram

    Set 15, 2008 ... DRAFT LOCAL LAND USE GUIDANCE FLOW DIAGRAM New Land Use Project Residential Development Screening Criteria Below Screening • Source-specific setbacks • Multiple source screen Above ...

    Read More
    (49 Kb PDF, 1 pg)

    Set 15, 2008 ... DRAFT LOCAL LAND USE GUIDANCE FLOW DIAGRAM New Land Use Project Residential Development Screening Criteria Below Screening • Source-specific setbacks • Multiple source screen Above ...

  • RFQ 2017-001 AQ Data Analyses, Modeling and Health Impact Assessments
    RFQ 2017-001 AQ Data Analyses, Modeling and Health Impact Assessments

    Mar 16, 2017 ... March 16, 2017 Request for Qualifications #2017-001 Air Quality Data Analyses, Modeling, and Health Impact Assessments SECTION I – SUMMARY ...

    Read More
    (75 Kb PDF, 7 pgs)

    Mar 16, 2017 ... March 16, 2017 Request for Qualifications #2017-001 Air Quality Data Analyses, Modeling, and Health Impact Assessments SECTION I – SUMMARY ...

  • Approved Chevron AutoGC SOP
    Approved Chevron AutoGC SOP

    Okt 23, 2024 ... Synspec GC955 Hydrocarbon Analyzer SOP, STI-7984 Version 3 October 31, 2024 Page 1 of 27 Standard Operating Procedure for Synspec GC955 Hydrocarbon Analyzer October 31, 2024 STI-7984 ...

    Read More
    (1 Mb PDF, 27 pgs)

    Okt 23, 2024 ... Synspec GC955 Hydrocarbon Analyzer SOP, STI-7984 Version 3 October 31, 2024 Page 1 of 27 Standard Operating Procedure for Synspec GC955 Hydrocarbon Analyzer October 31, 2024 STI-7984 ...

  • Air Cleaner Flyer_EN_071625
    Air Cleaner Flyer_EN_071625

    Hul 16, 2025 ... THE BEST WAYS TO USE AIR CLEANERS 1 Place the air cleaner (also known as air purifier) 7 FILTER REPLACEMENT so that it is 6” away from the nearest object Filters need to be changed regularly. Most ...

    Read More
    (322 Kb PDF, 1 pg)

    Hul 16, 2025 ... THE BEST WAYS TO USE AIR CLEANERS 1 Place the air cleaner (also known as air purifier) 7 FILTER REPLACEMENT so that it is 6” away from the nearest object Filters need to be changed regularly. Most ...

Spare the Air Status

Huling Isinapanahon: 11/8/2016