Advisory
|
Valero Refinery in Benicia notified the Air District of ongoing flaring due to a planned shutdown of refinery equipment. Air District inspectors will be closely monitoring. Report air quality complaints: 800-334-ODOR or online.
|
|
125 results for 'gdf'
Search: 'gdf'
125 Search:
May 19, 2004 ... PERMIT SERVICES DIVISION May 5, 2004 PERMIT ADVISORY #PSD-04-A DRAIN VALVES ON VAPOR SPILL BOXES NO LONGER ALLOWED Effective June 1, 2004, drain valves will no longer be allowed on ...
Read MoreMay 19, 2004 ... PERMIT SERVICES DIVISION May 5, 2004 PERMIT ADVISORY #PSD-04-A DRAIN VALVES ON VAPOR SPILL BOXES NO LONGER ALLOWED Effective June 1, 2004, drain valves will no longer be allowed on ...
Oct 6, 2025 ... BAY AREA AIR QUALITY MANAGEMENT DISTRICT Engineering Division 375 Beale Street, Suite 60 0 San Francisco, CA 94105 www.baaqmd.gov Instruc�ons: Gasoline Dispensing Facility Equipment ...
Read MoreOct 6, 2025 ... BAY AREA AIR QUALITY MANAGEMENT DISTRICT Engineering Division 375 Beale Street, Suite 60 0 San Francisco, CA 94105 www.baaqmd.gov Instruc�ons: Gasoline Dispensing Facility Equipment ...
Mar 18, 2013 ... Compliance AAdvisory March 18, 2013 Notificaation and Submisssion of GGDF Sourcce Tests Thisis Advisory is provided to innform you aboout Air District activities thaat may affect yyour ...
Read MoreMar 18, 2013 ... Compliance AAdvisory March 18, 2013 Notificaation and Submisssion of GGDF Sourcce Tests Thisis Advisory is provided to innform you aboout Air District activities thaat may affect yyour ...
Feb 21, 2003 ... Source Test Procedure ST-39 GASOLINE DISPENSING FACILITIES AIR TO LIQUID VOLUMETRIC RATIO REF: Regulation 8-7-302 1. APPLICABILITY 1.1 This test procedure is used to quantify the Air to ...
Read MoreFeb 21, 2003 ... Source Test Procedure ST-39 GASOLINE DISPENSING FACILITIES AIR TO LIQUID VOLUMETRIC RATIO REF: Regulation 8-7-302 1. APPLICABILITY 1.1 This test procedure is used to quantify the Air to ...
Thg3 5, 2012 ... New Technology System – Gasoline Dispensing Stations ...
Read MoreThg3 5, 2012 ... New Technology System – Gasoline Dispensing Stations ...
Tìm hiểu về khả năng phân tích và giám sát của Địa Hạt Không Khí.
Read MoreTìm hiểu về khả năng phân tích và giám sát của Địa Hạt Không Khí.
Jul 30, 2012 ... Bay Area Air Quality Management District 939 Ellis Street San Francisco, CA 94109 (415) 749-5000 Board of Directors Regular Meeting June 6, 2012 APPROVED MINUTES CALL TO ORDER ...
Read MoreJul 30, 2012 ... Bay Area Air Quality Management District 939 Ellis Street San Francisco, CA 94109 (415) 749-5000 Board of Directors Regular Meeting June 6, 2012 APPROVED MINUTES CALL TO ORDER ...
Aug 23, 2005 ... Compliance and Enforcement Division August 17, 2005 Compliance Advisory _____________________________________________________ This Advisory is provided to inform you about activities of the ...
Read MoreAug 23, 2005 ... Compliance and Enforcement Division August 17, 2005 Compliance Advisory _____________________________________________________ This Advisory is provided to inform you about activities of the ...
Nov 13, 2009 ... PROPOSED CHANGES TO REGULATION 2, RULE 5 AND THE HEALTH RISK SCREENING ANALYSIS (HRSA) GUIDELINES: SOCIOECONOMIC IMPACT ANALYSIS DRAFT NOVEMBER 13, 2009 ...
Read MoreNov 13, 2009 ... PROPOSED CHANGES TO REGULATION 2, RULE 5 AND THE HEALTH RISK SCREENING ANALYSIS (HRSA) GUIDELINES: SOCIOECONOMIC IMPACT ANALYSIS DRAFT NOVEMBER 13, 2009 ...
Oct 28, 2024 ... ENGINEERING EVALUATION Facility ID No. 203638 Costco Gasoline (Loc. No. 1684) Admiral Callaghan Lane & Turner Parkway, Vallejo, CA 94591 Application No. 711068 BACKGROUND The ...
Read MoreOct 28, 2024 ... ENGINEERING EVALUATION Facility ID No. 203638 Costco Gasoline (Loc. No. 1684) Admiral Callaghan Lane & Turner Parkway, Vallejo, CA 94591 Application No. 711068 BACKGROUND The ...
Feb 21, 2003 ... Source Test Procedure ST-30 STATIC PRESSURE INTEGRITY TEST UNDERGROUND STORAGE TANKS (Adopted November 30, 1983) REF: Regulation 8-7-301, 302 1. APPLICABILITY 1.1 This ...
Read MoreFeb 21, 2003 ... Source Test Procedure ST-30 STATIC PRESSURE INTEGRITY TEST UNDERGROUND STORAGE TANKS (Adopted November 30, 1983) REF: Regulation 8-7-301, 302 1. APPLICABILITY 1.1 This ...
Jan 23, 2025 ... DRAFT ENGINEERING EVALUATION Facility ID No. 203748 California Fire Hood Mountain Fire Center 538 Eliza Way Santa Rosa, CA 95409 Application No. 716535 BACKGROUND The applicant has ...
Read MoreJan 23, 2025 ... DRAFT ENGINEERING EVALUATION Facility ID No. 203748 California Fire Hood Mountain Fire Center 538 Eliza Way Santa Rosa, CA 95409 Application No. 716535 BACKGROUND The applicant has ...
Jun 9, 2025 ... DRAFT - ENGINEERING EVALUATION Facility ID No. 203851 Safeway Fuel Center #2657 982 Laurel Road Oakley, CA 94561 Application No. 723091 BACKGROUND The applicant has requested an ...
Read MoreJun 9, 2025 ... DRAFT - ENGINEERING EVALUATION Facility ID No. 203851 Safeway Fuel Center #2657 982 Laurel Road Oakley, CA 94561 Application No. 723091 BACKGROUND The applicant has requested an ...
Sep 4, 2024 ... DRAFT ENGINEERING EVALUATION Facility ID No. 203658 City of American Canyon Corporation Yard 300 Napa Junction Road, American Canyon, CA 94503 Application No. 712190 BACKGROUND The ...
Read MoreSep 4, 2024 ... DRAFT ENGINEERING EVALUATION Facility ID No. 203658 City of American Canyon Corporation Yard 300 Napa Junction Road, American Canyon, CA 94503 Application No. 712190 BACKGROUND The ...
Mar 15, 2022 ... DRAFT ENGINEERING EVALUATION Facility ID No. 111724 ARCO AM/PM 3010 Mount Vista Drive, San Jose, CA 95127 Application No. 647125 BACKGROUND The applicant has requested to modify the ...
Read MoreMar 15, 2022 ... DRAFT ENGINEERING EVALUATION Facility ID No. 111724 ARCO AM/PM 3010 Mount Vista Drive, San Jose, CA 95127 Application No. 647125 BACKGROUND The applicant has requested to modify the ...
Jun 26, 2008 ... EVR Phase II Retail Advisory Compliance and Enforcement Division June 26, 2008 Compliance Advisory This Advisory is provided to inform you about activities of the Air District which may affect ...
Read MoreJun 26, 2008 ... EVR Phase II Retail Advisory Compliance and Enforcement Division June 26, 2008 Compliance Advisory This Advisory is provided to inform you about activities of the Air District which may affect ...
Mar 20, 2020 ... DRAFT ENGINEERING EVALUATION Facility ID No. 100156 Costco Gasoline # 475 1600 El Camino Real South San Francisco, CA 94080 Application No. 479612 BACKGROUND The applicant has ...
Read MoreMar 20, 2020 ... DRAFT ENGINEERING EVALUATION Facility ID No. 100156 Costco Gasoline # 475 1600 El Camino Real South San Francisco, CA 94080 Application No. 479612 BACKGROUND The applicant has ...
Feb 16, 2017 ... AGENDA: 4 BAY AREA AIR QUALITY MANAGEMENT DISTRICT Memorandum To: Chairperson Liz Kniss and Members of the Executive Committee From: Chairperson Terry Trumbull, Esq., and ...
Read MoreFeb 16, 2017 ... AGENDA: 4 BAY AREA AIR QUALITY MANAGEMENT DISTRICT Memorandum To: Chairperson Liz Kniss and Members of the Executive Committee From: Chairperson Terry Trumbull, Esq., and ...
Dec 3, 2025 ... ENGINEERING EVALUATION Facility ID No. 111865 Richmond 1001 Petroleum Inc #111865 1001 Cutting Blvd, Richmond, CA 94804 Application No. 732101 BACKGROUND The applicant has requested ...
Read MoreDec 3, 2025 ... ENGINEERING EVALUATION Facility ID No. 111865 Richmond 1001 Petroleum Inc #111865 1001 Cutting Blvd, Richmond, CA 94804 Application No. 732101 BACKGROUND The applicant has requested ...
Cập Nhật Lần Cuối: 08/11/2016