Hanapin

  • 26178 Permit Evaluation
    26178 Permit Evaluation

    Oct 15, 2014 ... Engineering Evaluation Former UST Site. Plant Number20608 Application Number 26178 Background On behalf of UST, Calclean has applied for an Authority to Construct for the following ...

    Read More
    (222 Kb PDF, 7 pgs)

    Oct 15, 2014 ... Engineering Evaluation Former UST Site. Plant Number20608 Application Number 26178 Background On behalf of UST, Calclean has applied for an Authority to Construct for the following ...

  • 25427 Permit Evaluation
    25427 Permit Evaluation

    Mar 9, 2015 ... DRAFT Engineering Evaluation Chevron Environmental Management Company Plant No. 21947; Application No. 25427 706 Harrison Street, Oakland, CA 94607 ARCADIS U.S., Inc. on behalf of Chevron ...

    Read More
    (67 Kb PDF, 5 pgs)

    Mar 9, 2015 ... DRAFT Engineering Evaluation Chevron Environmental Management Company Plant No. 21947; Application No. 25427 706 Harrison Street, Oakland, CA 94607 ARCADIS U.S., Inc. on behalf of Chevron ...

  • 23844 Permit Evaluation
    23844 Permit Evaluation

    Jan 26, 2012 ... Earl Scheib Oakland Application Number: 23844 901 International Blvd Plant Number: 20984 Oakland, CA 94606 Background: Earl Scheib Oakland, located in Oakland, is applying for ...

    Read More
    (154 Kb PDF, 7 pgs)

    Jan 26, 2012 ... Earl Scheib Oakland Application Number: 23844 901 International Blvd Plant Number: 20984 Oakland, CA 94606 Background: Earl Scheib Oakland, located in Oakland, is applying for ...

  • 23774 Permit Evaluation
    23774 Permit Evaluation

    Jan 31, 2012 ... Integrity Auto Collision Application Number: 23774 1891 Woolner Ave, #C Plant Number: 20953 Fairfield, CA 94533 Background: Integrity Auto Collision, located in Fairfield, is ...

    Read More
    (155 Kb PDF, 7 pgs)

    Jan 31, 2012 ... Integrity Auto Collision Application Number: 23774 1891 Woolner Ave, #C Plant Number: 20953 Fairfield, CA 94533 Background: Integrity Auto Collision, located in Fairfield, is ...

  • 18804 Permit Evaluation
    18804 Permit Evaluation

    Jan 9, 2009 ... DRAFT Engineering Evaluation Sales Force Plant Number: 19272, and Application Number: 18804 ...

    Read More
    (106 Kb PDF, 8 pgs)

    Jan 9, 2009 ... DRAFT Engineering Evaluation Sales Force Plant Number: 19272, and Application Number: 18804 ...

  • 27709 Permit Evaluation
    27709 Permit Evaluation

    Apr 17, 2018 ... DRAFT EVALUATION REPORT Central Concrete Supply Company Application #27709 - Plant #2049 790 Stockton Avenue San Jose, CA 95126 I. BACKGROUND Central Concrete Supply Company (CCSC) has ...

    Read More
    (652 Kb PDF, 9 pgs)

    Apr 17, 2018 ... DRAFT EVALUATION REPORT Central Concrete Supply Company Application #27709 - Plant #2049 790 Stockton Avenue San Jose, CA 95126 I. BACKGROUND Central Concrete Supply Company (CCSC) has ...

  • 26654 Permit Evaluation
    26654 Permit Evaluation

    Jan 29, 2015 ... Engineering Evaluation Report 2558 Mission, LLC Application #26654; Plant # 22709 1. BACKGROUND The application is for a Permit to Operate a 464 Bhp diesel engine used as a driver for an ...

    Read More
    (150 Kb PDF, 9 pgs)

    Jan 29, 2015 ... Engineering Evaluation Report 2558 Mission, LLC Application #26654; Plant # 22709 1. BACKGROUND The application is for a Permit to Operate a 464 Bhp diesel engine used as a driver for an ...

  • 31401 Permit Evaluation
    31401 Permit Evaluation

    Feb 16, 2022 ... Plant 25072: Invitae Corporation Application 31401: De Haro Standby Emergency Natural Gas Generator Engine ENGINEERING EVALUATION Plant 25072: Invitae Corporation 444 De Haro Street, Suite 110, ...

    Read More
    (156 Kb PDF, 11 pgs)

    Feb 16, 2022 ... Plant 25072: Invitae Corporation Application 31401: De Haro Standby Emergency Natural Gas Generator Engine ENGINEERING EVALUATION Plant 25072: Invitae Corporation 444 De Haro Street, Suite 110, ...

  • 31569 Permit Evaluation
    31569 Permit Evaluation

    Sep 14, 2022 ... Mainspring Energy, Inc, Plant #25153 TRADE SECRET Application #31569 PUBLIC DRAFT ENGINEERING ...

    Read More
    (149 Kb PDF, 7 pgs)

    Sep 14, 2022 ... Mainspring Energy, Inc, Plant #25153 TRADE SECRET Application #31569 PUBLIC DRAFT ENGINEERING ...

  • Engineering Evaluation
    Engineering Evaluation

    Dec 14, 2006 ... Bay Area Air Quality Management District 939 Ellis Street San Francisco, CA 94109 (415) 771-6000 Permit Evaluation and Statement of Basis for MAJOR FACILITY REVIEW PERMIT Reopening ...

    Read More
    (661 Kb PDF, 163 pgs)

    Dec 14, 2006 ... Bay Area Air Quality Management District 939 Ellis Street San Francisco, CA 94109 (415) 771-6000 Permit Evaluation and Statement of Basis for MAJOR FACILITY REVIEW PERMIT Reopening ...

  • 415004 Permit Evaluation
    415004 Permit Evaluation

    Jun 6, 2016 ... DRAFT EVALUATION REPORT Sunnyvale Chevron 1005 W. El Camino Real Sunnyvale, CA 94087 FID #111866 Application #415004 BACKGROUND Sunnyvale Chevron has requested to increase the ...

    Read More
    (89 Kb PDF, 3 pgs)

    Jun 6, 2016 ... DRAFT EVALUATION REPORT Sunnyvale Chevron 1005 W. El Camino Real Sunnyvale, CA 94087 FID #111866 Application #415004 BACKGROUND Sunnyvale Chevron has requested to increase the ...

  • 31209 Permit Evaluation
    31209 Permit Evaluation

    Jul 9, 2021 ... Application 31209 Facility 24999 PUBLIC VERSION DRAFT ENGINEERING EVALUATION Application No. 31209 Facility ID No. 24999 Mainspring Energy Inc. Cold Springs Rd & Howell Mountain ...

    Read More
    (242 Kb PDF, 8 pgs)

    Jul 9, 2021 ... Application 31209 Facility 24999 PUBLIC VERSION DRAFT ENGINEERING EVALUATION Application No. 31209 Facility ID No. 24999 Mainspring Energy Inc. Cold Springs Rd & Howell Mountain ...

  • 20604 Permit Evaluation
    20604 Permit Evaluation

    Jul 8, 2009 ... ENGINEERING EVALUATION Kin’s Cabinets, Plant: 19666 Application: 20604 BACKGROUND Kin’s Cabinets moved from their prior location in Pacifica, California (P# 13298) to their new location in ...

    Read More
    (38 Kb PDF, 3 pgs)

    Jul 8, 2009 ... ENGINEERING EVALUATION Kin’s Cabinets, Plant: 19666 Application: 20604 BACKGROUND Kin’s Cabinets moved from their prior location in Pacifica, California (P# 13298) to their new location in ...

  • 409789 Permit Evaluation
    409789 Permit Evaluation

    May 4, 2015 ... DRAFT EVALUATION REPORT Redwood Road Chevron 2008 Redwood Road Napa, CA 94558 FID #109383 Application #409789 BACKGROUND Redwood Road Chevron has submitted this application to ...

    Read More
    (13 Kb PDF, 3 pgs)

    May 4, 2015 ... DRAFT EVALUATION REPORT Redwood Road Chevron 2008 Redwood Road Napa, CA 94558 FID #109383 Application #409789 BACKGROUND Redwood Road Chevron has submitted this application to ...

  • Discussion Summary
    Discussion Summary

    Mar 26, 2026 ... PERMITTING EFFICIENCY TASKFORCE DISCUSSION SUMMARY TUESDAY, FEBRUARY 24, 2026 1:00 PM – 3:00 PM Staff contact: Brian Butler Janet Whittick, Engineering Program Manager, ...

    Read More
    (167 Kb PDF, 2 pgs)

    Mar 26, 2026 ... PERMITTING EFFICIENCY TASKFORCE DISCUSSION SUMMARY TUESDAY, FEBRUARY 24, 2026 1:00 PM – 3:00 PM Staff contact: Brian Butler Janet Whittick, Engineering Program Manager, ...

  • 30890 Permit Evaluation
    30890 Permit Evaluation

    Aug 25, 2021 ... ENGINEERING EVALUATION Facility ID No. 3893 Sonoma Valley Hospital District 347 Andrieux Street, Sonoma, CA 95476 Application No. 30890 BACKGROUND Sonoma Valley Hospital District has applied ...

    Read More
    (259 Kb PDF, 11 pgs)

    Aug 25, 2021 ... ENGINEERING EVALUATION Facility ID No. 3893 Sonoma Valley Hospital District 347 Andrieux Street, Sonoma, CA 95476 Application No. 30890 BACKGROUND Sonoma Valley Hospital District has applied ...

  • 27505 Permit Evaluation
    27505 Permit Evaluation

    Apr 8, 2016 ... Draft Engineering Evaluation San Mateo Water Quality Control Plant 2050 Detroit Drive, San Mateo, CA 94404 Plant No. 861 Application No. 27505 Project Description: New Dual-Fueled Digester ...

    Read More
    (518 Kb PDF, 16 pgs)

    Apr 8, 2016 ... Draft Engineering Evaluation San Mateo Water Quality Control Plant 2050 Detroit Drive, San Mateo, CA 94404 Plant No. 861 Application No. 27505 Project Description: New Dual-Fueled Digester ...

  • Engineering Evaluation
    Engineering Evaluation

    Aug 11, 2011 ... Bay Area Air Quality Management District 939 Ellis Street San Francisco, CA 94109 (415) 771-6000 Permit Evaluation and Statement of Basis for Major Facility Review Permit TV Renewal ...

    Read More
    (8 Mb PDF, 114 pgs)

    Aug 11, 2011 ... Bay Area Air Quality Management District 939 Ellis Street San Francisco, CA 94109 (415) 771-6000 Permit Evaluation and Statement of Basis for Major Facility Review Permit TV Renewal ...

  • Statement of Basis
    Statement of Basis

    May 16, 2011 ... Bay Area Air Quality Management District 939 Ellis Street San Francisco, CA 94109 (415) 771-6000 Permit Evaluation and Statement of Basis for Major Facility Review Permit TV Renewal ...

    Read More
    (8 Mb PDF, 114 pgs)

    May 16, 2011 ... Bay Area Air Quality Management District 939 Ellis Street San Francisco, CA 94109 (415) 771-6000 Permit Evaluation and Statement of Basis for Major Facility Review Permit TV Renewal ...

Spare the Air Status

Huling Isinapanahon: 11/8/2016