133 results for 'sampling'
Search: 'sampling'
133 Search:
The Air District is convening a community workgroup to inform development and implementation of our new Particle Fallout Sampling Program for refinery communities. We are looking for people who live or work near the Chevron, Marathon, MRC, Phillips 66, and Valero refineries, or who represent organizations and environmental groups that serve these communities.
Read MoreThe Air District is convening a community workgroup to inform development and implementation of our new Particle Fallout Sampling Program for refinery communities. We are looking for people who live or work near the Chevron, Marathon, MRC, Phillips 66, and Valero refineries, or who represent organizations and environmental groups that serve these communities.
Oct 1, 1996 ... Source Test Procedure ST-23 WATER VAPOR (Adopted January 20, 1982) 1. APPLICABILITY 1.1 This method is used to quantify the water vapor content of stack gases. It is applicable in all cases in which ...
Read MoreOct 1, 1996 ... Source Test Procedure ST-23 WATER VAPOR (Adopted January 20, 1982) 1. APPLICABILITY 1.1 This method is used to quantify the water vapor content of stack gases. It is applicable in all cases in which ...
Jan 18, 2018 ... Sampling Study Protocol Specifications for Third-Party Verifiers Fugitive Emissions from Petroleum Refinery Equipment in Heavy Liquid Service Joint Study between the Bay Area Air ...
Read MoreJan 18, 2018 ... Sampling Study Protocol Specifications for Third-Party Verifiers Fugitive Emissions from Petroleum Refinery Equipment in Heavy Liquid Service Joint Study between the Bay Area Air ...
Sep 27, 1996 ... Source Test Method ST-8 DIMETHYLSULFIDE (Adopted January 20, 1982) REF: Regulation 7-303 1. APPLICABILITY 1.1 This method is used to determine emissions of dimethylsulfide (DMS). It is applicable ...
Read MoreSep 27, 1996 ... Source Test Method ST-8 DIMETHYLSULFIDE (Adopted January 20, 1982) REF: Regulation 7-303 1. APPLICABILITY 1.1 This method is used to determine emissions of dimethylsulfide (DMS). It is applicable ...
Oct 1, 1996 ... Source Test Procedure ST-22 TRIMETHYLAMINE (Adopted January 20, 1982) REF: Regulation 7-303 1. APPLICABILITY 1.1 This method is used to quantify emissions of Trimethylamine (TMA). It determines ...
Read MoreOct 1, 1996 ... Source Test Procedure ST-22 TRIMETHYLAMINE (Adopted January 20, 1982) REF: Regulation 7-303 1. APPLICABILITY 1.1 This method is used to quantify emissions of Trimethylamine (TMA). It determines ...
May 6, 2016 ... MOP Vol. IX Procedure – P‐1 Volatile Organic Compounds Water Sampling PROCEDURE - 1 ORGANIC COMPOUNDS WATER SAMPLING REF: Regulation 11-10 1. APPLICABILITY 1.1 This procedure is used to ...
Read MoreMay 6, 2016 ... MOP Vol. IX Procedure – P‐1 Volatile Organic Compounds Water Sampling PROCEDURE - 1 ORGANIC COMPOUNDS WATER SAMPLING REF: Regulation 11-10 1. APPLICABILITY 1.1 This procedure is used to ...
Set 27, 1996 ... Source Test Method ST-11 MERCAPTANS Adopted (January 20, 1982) REF: Regulation 7-303 1. APPLICABILITY 1.1 This method is used to determine emissions of mercaptans. It is applicable to the ...
Read MoreSet 27, 1996 ... Source Test Method ST-11 MERCAPTANS Adopted (January 20, 1982) REF: Regulation 7-303 1. APPLICABILITY 1.1 This method is used to determine emissions of mercaptans. It is applicable to the ...
Sep 26, 1996 ... Source Test Procedure ST-1B AMMONIA INTEGRATED SAMPLING (Adopted January 20, 1982) REF: Regulation 7-303 1. APPLICABILITY 1.1 This method is used to quantify emissions of ammonia. It ...
Read MoreSep 26, 1996 ... Source Test Procedure ST-1B AMMONIA INTEGRATED SAMPLING (Adopted January 20, 1982) REF: Regulation 7-303 1. APPLICABILITY 1.1 This method is used to quantify emissions of ammonia. It ...
Set 27, 1996 ... Source Test Procedure ST-9 LEAD Adopted (January 20, 1982) REF: Regulation, 11-1-301 1. APPLICABILITY 1.1 This procedure is used to quantify emissions of Lead. It determines compliance with ...
Read MoreSet 27, 1996 ... Source Test Procedure ST-9 LEAD Adopted (January 20, 1982) REF: Regulation, 11-1-301 1. APPLICABILITY 1.1 This procedure is used to quantify emissions of Lead. It determines compliance with ...
May 10, 2023 ... May 10, 2023 Request for Qualifications# 2023-030 Air Sampling Network Maintenance and Operations SECTION I – SUMMARY ...
Read MoreMay 10, 2023 ... May 10, 2023 Request for Qualifications# 2023-030 Air Sampling Network Maintenance and Operations SECTION I – SUMMARY ...
Feb 2, 2021 ... February 3, 2021 Request for Qualifications# 2020-001 Air Sampling Network Maintenance and Operations SECTION I – SUMMARY ...
Read MoreFeb 2, 2021 ... February 3, 2021 Request for Qualifications# 2020-001 Air Sampling Network Maintenance and Operations SECTION I – SUMMARY ...
Sep 27, 1996 ... Source Test Procedure ST-19A SULFUR DIOXIDE, CONTINUOUS SAMPLING (Adopted January 20, 1982) REF: Regulations 9-1-302, 9-1-304 through 310, 10-1-301 1. APPLICABILITY 1.1 This method is used to ...
Read MoreSep 27, 1996 ... Source Test Procedure ST-19A SULFUR DIOXIDE, CONTINUOUS SAMPLING (Adopted January 20, 1982) REF: Regulations 9-1-302, 9-1-304 through 310, 10-1-301 1. APPLICABILITY 1.1 This method is used to ...
Sep 27, 1996 ... Source Test Procedure ST-13A OXIDES OF NITROGEN, CONTINUOUS SAMPLING REF: Regulations 9-3-301, 9-3-302, 10-1-301 1. APPLICABILITY 1.1 This method is used to quantify emissions of oxides of nitrogen.
Read MoreSep 27, 1996 ... Source Test Procedure ST-13A OXIDES OF NITROGEN, CONTINUOUS SAMPLING REF: Regulations 9-3-301, 9-3-302, 10-1-301 1. APPLICABILITY 1.1 This method is used to quantify emissions of oxides of nitrogen.
Oct 1, 1996 ... Source Test Procedure ST-24 TANK SAMPLING FOR ORSAT ANALYSIS (CO, CO , O ) 2 2 REF: Regulations 6-310.1, 8-1-110.3, 10-3-301, 9-3-301 through 9-3-304 1. APPLICABILITY 1.1 This procedure is used to ...
Read MoreOct 1, 1996 ... Source Test Procedure ST-24 TANK SAMPLING FOR ORSAT ANALYSIS (CO, CO , O ) 2 2 REF: Regulations 6-310.1, 8-1-110.3, 10-3-301, 9-3-301 through 9-3-304 1. APPLICABILITY 1.1 This procedure is used to ...
Aug 27, 2013 ... Guidelines for Construction of Particulate Sampling and Testing Facilities Introduction Selection of a proper sampling site is vital to assure representative measurement of pollutant ...
Read MoreAug 27, 2013 ... Guidelines for Construction of Particulate Sampling and Testing Facilities Introduction Selection of a proper sampling site is vital to assure representative measurement of pollutant ...
Aug 11, 2023 ... South Bay Odor Attribution Study Final Report 230407112709_08bfbc6e Bay Area Air Quality Management District Document Title B a y A r e a A i r Q u a l i t y M a n a g ...
Read MoreAug 11, 2023 ... South Bay Odor Attribution Study Final Report 230407112709_08bfbc6e Bay Area Air Quality Management District Document Title B a y A r e a A i r Q u a l i t y M a n a g ...
Sep 9, 2010 ... West Oakland Monitoring Study DRAFT REPORT APPENDICES Sampling and Analytical Methods Prepared for: Bay Area Air Quality Management District 939 Ellis Street ...
Read MoreSep 9, 2010 ... West Oakland Monitoring Study DRAFT REPORT APPENDICES Sampling and Analytical Methods Prepared for: Bay Area Air Quality Management District 939 Ellis Street ...
May 21, 2012 ... Facility Name: SFPP. L.P. San Jose Terminal #: A4020 Permit for Facility Page #l through April 30,2012 Report for Period November 1,201l Title V Monitoring Verifìcation Semi-Annual Table VII - ...
Read MoreMay 21, 2012 ... Facility Name: SFPP. L.P. San Jose Terminal #: A4020 Permit for Facility Page #l through April 30,2012 Report for Period November 1,201l Title V Monitoring Verifìcation Semi-Annual Table VII - ...
Huling Isinapanahon: 11/8/2016