Sep 27, 1996 ... Source Test Procedure ST-5 CARBON DIOXIDE, CONTINUOUS SAMPLING REF: Regulation 6-310.1 1. APPLICABILITY 1.1 This method is used to quantify emissions of carbon dioxide. It determines compliance ...
Read MoreSep 27, 1996 ... Source Test Procedure ST-5 CARBON DIOXIDE, CONTINUOUS SAMPLING REF: Regulation 6-310.1 1. APPLICABILITY 1.1 This method is used to quantify emissions of carbon dioxide. It determines compliance ...
Oct 1, 1996 ... Source Test Procedure ST-26 COKE BURN-OFF RATE REF: Regulation 10-8-301 1. APPLICABLITY 1.1 In order to determine compliance with Regulation 10-8-301 for particulate emissions from Fluid Catalytic ...
Read MoreOct 1, 1996 ... Source Test Procedure ST-26 COKE BURN-OFF RATE REF: Regulation 10-8-301 1. APPLICABLITY 1.1 In order to determine compliance with Regulation 10-8-301 for particulate emissions from Fluid Catalytic ...
Sep 27, 1996 ... SOURCE TEST PROCEDURE ST-7 ORGANIC COMPOUNDS REF: Regulation 8 1. APPLICABILITY 1.1 This procedure is used to quantify emissions of organic compounds. It is applicable to the determination of ...
Read MoreSep 27, 1996 ... SOURCE TEST PROCEDURE ST-7 ORGANIC COMPOUNDS REF: Regulation 8 1. APPLICABILITY 1.1 This procedure is used to quantify emissions of organic compounds. It is applicable to the determination of ...
Sep 27, 1996 ... Source Test Procedure ST-6 CARBON MONOXIDE, CONTINUOUS SAMPLING REF: Regulation 8-1-110.3, 10-8-301 1. APPLICABILITY 1.1 This method is used to quantify emissions of carbon monoxide (CO).
Read MoreSep 27, 1996 ... Source Test Procedure ST-6 CARBON MONOXIDE, CONTINUOUS SAMPLING REF: Regulation 8-1-110.3, 10-8-301 1. APPLICABILITY 1.1 This method is used to quantify emissions of carbon monoxide (CO).
May 6, 2016 ... MOP Vol. IV ST-40 Strippable Volatile Organic Compounds SOURCE TEST PROCEDURE ST- 40 STRIPPABLE VOLATILE ORGANIC COMPOUNDS REF: Regulation 11-10 1. APPLICABILITY 1.1 This procedure is used to ...
Read MoreMay 6, 2016 ... MOP Vol. IV ST-40 Strippable Volatile Organic Compounds SOURCE TEST PROCEDURE ST- 40 STRIPPABLE VOLATILE ORGANIC COMPOUNDS REF: Regulation 11-10 1. APPLICABILITY 1.1 This procedure is used to ...
Oct 1, 1996 ... Source Test Procedure ST-37 GASOLINE DISPENSING FACILITY LIQUID REMOVAL DEVICES (Adopted December 21, 1994) REF: 8-7-302, 317 1. APPLICABILITY 1.1 This procedure is used to quantify the removal of ...
Read MoreOct 1, 1996 ... Source Test Procedure ST-37 GASOLINE DISPENSING FACILITY LIQUID REMOVAL DEVICES (Adopted December 21, 1994) REF: 8-7-302, 317 1. APPLICABILITY 1.1 This procedure is used to quantify the removal of ...
Sep 27, 1996 ... Source Test Procedure ST-13A OXIDES OF NITROGEN, CONTINUOUS SAMPLING REF: Regulations 9-3-301, 9-3-302, 10-1-301 1. APPLICABILITY 1.1 This method is used to quantify emissions of oxides of nitrogen.
Read MoreSep 27, 1996 ... Source Test Procedure ST-13A OXIDES OF NITROGEN, CONTINUOUS SAMPLING REF: Regulations 9-3-301, 9-3-302, 10-1-301 1. APPLICABILITY 1.1 This method is used to quantify emissions of oxides of nitrogen.
Oct 23, 2015 ... Floor Barcode # Description Additional Description Finish Mfg. Model # Length/ Width Depth Height Color Qty Photo 1 6190 Cabinet Wood 36 13 48 Walnut 1 6195 1 6191 Chair, guest Without arms Vinyl ...
Read MoreOct 23, 2015 ... Floor Barcode # Description Additional Description Finish Mfg. Model # Length/ Width Depth Height Color Qty Photo 1 6190 Cabinet Wood 36 13 48 Walnut 1 6195 1 6191 Chair, guest Without arms Vinyl ...
Oct 23, 2015 ... Floor Barcode # Description Additional Description Finish Mfg. Model # Length/ Width Depth Height Color Qty Photo 1 6190 Cabinet Wood 36 13 48 Walnut 1 6195 1 6191 Chair, guest Without arms Vinyl ...
Read MoreOct 23, 2015 ... Floor Barcode # Description Additional Description Finish Mfg. Model # Length/ Width Depth Height Color Qty Photo 1 6190 Cabinet Wood 36 13 48 Walnut 1 6195 1 6191 Chair, guest Without arms Vinyl ...
Feb 21, 2003 ... Source Test Procedure ST-39 GASOLINE DISPENSING FACILITIES AIR TO LIQUID VOLUMETRIC RATIO REF: Regulation 8-7-302 1. APPLICABILITY 1.1 This test procedure is used to quantify the Air to ...
Read MoreFeb 21, 2003 ... Source Test Procedure ST-39 GASOLINE DISPENSING FACILITIES AIR TO LIQUID VOLUMETRIC RATIO REF: Regulation 8-7-302 1. APPLICABILITY 1.1 This test procedure is used to quantify the Air to ...
Oct 1, 1996 ... Source Test Procedure ST-24 TANK SAMPLING FOR ORSAT ANALYSIS (CO, CO , O ) 2 2 REF: Regulations 6-310.1, 8-1-110.3, 10-3-301, 9-3-301 through 9-3-304 1. APPLICABILITY 1.1 This procedure is used to ...
Read MoreOct 1, 1996 ... Source Test Procedure ST-24 TANK SAMPLING FOR ORSAT ANALYSIS (CO, CO , O ) 2 2 REF: Regulations 6-310.1, 8-1-110.3, 10-3-301, 9-3-301 through 9-3-304 1. APPLICABILITY 1.1 This procedure is used to ...
Dec 8, 2005 ... Source Test Procedure ST-34 BULK AND MARINE LOADING TERMINALS VAPOR RECOVERY UNITS (Adopted October 7, 1987) REF: Regulations 8-33-301, 308, 309, 8-6-302.1 and 8-44-301 1.
Read MoreDec 8, 2005 ... Source Test Procedure ST-34 BULK AND MARINE LOADING TERMINALS VAPOR RECOVERY UNITS (Adopted October 7, 1987) REF: Regulations 8-33-301, 308, 309, 8-6-302.1 and 8-44-301 1.
Oct 1, 1996 ... BAY AREA AIR QUALITY MANAGEMENT DISTRICT Manual of Procedures Volume IV Source Test Policy and ...
Read MoreOct 1, 1996 ... BAY AREA AIR QUALITY MANAGEMENT DISTRICT Manual of Procedures Volume IV Source Test Policy and ...
Aug 16, 2007 ... APPENDIX C-3 AIR MONITORING PROGRAMS ...
Read MoreAug 16, 2007 ... APPENDIX C-3 AIR MONITORING PROGRAMS ...
Apr 27, 2020 ... West Oakland Truck Management Plan Year One Implementation March 2020 Draft Parking Regulations & Draft Truck ...
Read MoreApr 27, 2020 ... West Oakland Truck Management Plan Year One Implementation March 2020 Draft Parking Regulations & Draft Truck ...
Mar 1, 2012 ... BAY AREA AIR QUALITY MANAGEMENT DISTRICT BAAQMD Engineering Division 939 Ellis Street, San Francisco, CA 94109 Instructions: Health Risk Screening Analysis (HRSA) Form Introduction ...
Read MoreMar 1, 2012 ... BAY AREA AIR QUALITY MANAGEMENT DISTRICT BAAQMD Engineering Division 939 Ellis Street, San Francisco, CA 94109 Instructions: Health Risk Screening Analysis (HRSA) Form Introduction ...
Feb 29, 2012 ... BAY AREA AIR QUALITY MANAGEMENT DISTRICT Mail to: BAAQMD HEALTH RISK ASSESSMENT FORM Engineering Division 375 Beale St., Suite 600 For permit applications that cause emission levels above ...
Read MoreFeb 29, 2012 ... BAY AREA AIR QUALITY MANAGEMENT DISTRICT Mail to: BAAQMD HEALTH RISK ASSESSMENT FORM Engineering Division 375 Beale St., Suite 600 For permit applications that cause emission levels above ...
Mar 1, 2017 ... BOARD OF DIRECTORS PUBLIC ENGAGEMENT COMMITTEE COMMITTEE MEMBERS MARK ROSS - CHAIR REBECCA KAPLAN – ...
Read MoreMar 1, 2017 ... BOARD OF DIRECTORS PUBLIC ENGAGEMENT COMMITTEE COMMITTEE MEMBERS MARK ROSS - CHAIR REBECCA KAPLAN – ...
Jan 31, 2019 ... BOARD OF DIRECTORS AD HOC BUILDING OVERSIGHT COMMITTEE MEETING COMMITTEE MEMBERS MARK ROSS – CHAIR DAVID CANEPA – VICE-CHAIR TERESA BARRETT PAULINE RUSSO - CUTTER ...
Read MoreJan 31, 2019 ... BOARD OF DIRECTORS AD HOC BUILDING OVERSIGHT COMMITTEE MEETING COMMITTEE MEMBERS MARK ROSS – CHAIR DAVID CANEPA – VICE-CHAIR TERESA BARRETT PAULINE RUSSO - CUTTER ...